EN 50131-2-2-2008 en Alarm systems - Intrusion and hold-up systems - Part 2-2 Intrusion detectors - Passive infrared detectors《报警系统 侵入和拦劫系统 第2-2部分 入侵探测器 无源红外侦测器》.pdf
《EN 50131-2-2-2008 en Alarm systems - Intrusion and hold-up systems - Part 2-2 Intrusion detectors - Passive infrared detectors《报警系统 侵入和拦劫系统 第2-2部分 入侵探测器 无源红外侦测器》.pdf》由会员分享,可在线阅读,更多相关《EN 50131-2-2-2008 en Alarm systems - Intrusion and hold-up systems - Part 2-2 Intrusion detectors - Passive infrared detectors《报警系统 侵入和拦劫系统 第2-2部分 入侵探测器 无源红外侦测器》.pdf(44页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 50131-2-2:2008Alarm systems Intrusion and hold-up systems Part 2-2: Intrusion detectors Passive infrared detectorsICS 13.310 BS EN 50131-2-2:2008Incorporating corrigendum May 2014EN 50131-2-2:2008/IS1:2014 (E) 4 Text of IS1 to EN 50131-2-2:2008 Clause: Annex A and Figure A.1 Qu
2、estion: Would it be allowed for test purposes (for test houses and manufacturers) to use the NeoDym magnet listed below instead of the AlNiCo version described in Annex A and Figure A.1 for reproducible tests ? Interpretation: Yes, because this will allow stable and reproducible test results, which
3、is not guaranteed while using the AlNiCo magnet due to the nature of the magnet material. Furthermore, the test magnet described below allows a high-level degree of backward compatibility for already tested products, while it gives the stability required. Therefore, when the NeoDym magnet is used fo
4、r test purposes (for test houses and manufacturers), the text below may be used in place of Annex A. Validity: This interpretation remains valid until an amendment or updated standard dealing with this issue is published by CENELEC. BS EN 50131-2-2:2008ISBN 978 0 580 83556 8Amendments/corrigenda iss
5、ued since publicationDate Comments31 May 2014 Implementation of CENELEC Interpretation sheet February 2014 in National Annex NAThis British Standard was published under the authority of the Standards Policy and Strategy Committee on 29 February 2008 The British Standards Institution 2014. Published
6、by BSI Standards Limited 2014National forewordThis British Standard is the UK implementation of EN 50131-2-2:2008. It supersedes DD CLC/TS 50131-2-2:2004 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee GW/1, Electronic security systems to Subcommittee
7、GW/1/1, Alarm components.A list of organizations represented on this subcommittee can be obtained on request to its secretary.The publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard c
8、annot confer immunity from legal obligations.EN 50131-2-2:2008/IS1:2014 (E) 4 Text of IS1 to EN 50131-2-2:2008 Clause: Annex A and Figure A.1 Question: Would it be allowed for test purposes (for test houses and manufacturers) to use the NeoDym magnet listed below instead of the AlNiCo version descri
9、bed in Annex A and Figure A.1 for reproducible tests ? Interpretation: Yes, because this will allow stable and reproducible test results, which is not guaranteed while using the AlNiCo magnet due to the nature of the magnet material. Furthermore, the test magnet described below allows a high-level d
10、egree of backward compatibility for already tested products, while it gives the stability required. Therefore, when the NeoDym magnet is used for test purposes (for test houses and manufacturers), the text below may be used in place of Annex A. Validity: This interpretation remains valid until an am
11、endment or updated standard dealing with this issue is published by CENELEC. BS EN 50131-2-2:2008National Annex NA (Informative)EN 50131-2-2:2008/IS1:2014 (E) 5 Annex A (normative) Dimensions it is not required to operate when the Ib) the manufacturers diagram of the detector and its claimed detecti
12、on boundary showing top andside elevations at 2,0 mmounting height or ata height specified by the manufacturer,superimposed upon a scaled 2 m squared grid. The size ofthe grid shall be directly related tothe size of the claimed detection boundary;c) the recommended mounting height, and the effect of
13、 changes to it on the claimed detection boundary;d) the effect of adjustable controls on the detectorsperformance or on the claimed detection boundary including atleast the minimum and maximum settings;e) any disallowed field adjustable control settings or combinations of these;f) any specific setti
14、ngs needed to meet the requirements of this European Standard at the claimed grade;g) where alignment adjustments are provided, these shallbe labelled as to theirfunction;h) a warning to the user not to obscure partially or completely the detectors field ofview;i) the manufacturers quoted nominal op
15、erating voltage, and the maximum and quiescent currentconsumption at thatvoltage;j) any special requirements needed for detecting a 50 % reduction in range, where provided.6 Testing The tests are intended tobe primarily concerned with verifying the correct operation of the detector tothe specificati
16、on provided by the manufacturer. Allthe test parameters specified shall carry a general tolerance of 10 % unless otherwise stated. A listof tests appears as a general test matrix inAnnex B.6.1 General test conditions6.1.1 Standard conditions for testingThe general atmospheric conditions in the measu
17、rement and tests laboratory shall be those specified in EN 60068-1, 5.3.1, unless stated otherwise.Temperature 15 C to 35 CRelative humidity25 % RH to 75 % RH Air pressure 86 kPa to 106 kPa 6.1.2 Generaldetection testing environment andprocedures Manufacturers documented instructions regarding mount
18、ing and operation shall be read and applied to alltests.BS EN 50131-2-2:2008EN 50131-2-2:2008EN 50131-2-2:2008 -14-6.1.3 TestingenvironmentThe detection tests require an enclosed, unobstructed and draught-free area that enables testing ofthe manufacturers claimed coverage pattern.The test area walls
19、 and floor shall have a recommended emissivity of at least 80 % between 8 m and14 m wavelength, at least directly behind the SWT.The temperature of the background surface immediately behind the SWT shall be in the range 15 Cto 25 C, and shall be horizontally uniform over that area to 2 C. Over the w
20、hole background area itshall be measured at ten points spread evenly throughout the coverage pattern. The average background temperature is the linear average ofthe ten points.The defaultmounting height shall be 2,0 m unless otherwisespecified by the manufacturer.Annex C provides example diagrams fo
21、rthe range of walk tests for one format of detection pattern.Many others are possible.6.1.4 Standard walk test targetThe SWT shall have the physical dimensions of 1,60 m to 1,85 m in height, shall weigh 70 kg 10 kgand shall wear close-fitting clothing having a recommended emissivity of at least 80 %
22、 between 8 mand 14 m wavelength.Temperatures shall be measured at the following five points on the front of the body of the SWT:1. Head 2. Chest3. Back of hand 4. Knee 5. FeetTemperatures shall be measured using a non-contact thermometer or equivalent equipment,The temperature differential at each b
23、ody point is measured, thenweighted and averaged as detailedin D.1.There shall be a means of calibration and control of the desired velocity at which the SWTis requiredto move. NOTE The use of a simulator/robotin place ofthe SWT is permitted, provided that it meets the specification of the SWT withr
24、egard to temperature. It isknownas the simulated target.In caseofconflict,a human walk test shall bethe primary reference.6.1.4.1Standard walk test target temperature differentialThe walk tests shall be performed either with an average temperature differential Dtr(as calculated inD.1) of 3,5 C 20 %,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN50131222008ENALARMSYSTEMSINTRUSIONANDHOLDUPSYSTEMSPART22INTRUSIONDETECTORSPASSIVEINFRAREDDETECTORS

链接地址:http://www.mydoc123.com/p-716712.html