EN 15198-2007 en Methodology for the risk assessment of non-electrical equipment and components for intended use in potentially explosive atmospheres《潜在易爆环境中使用的非电气设备和部件的风险评估方法》.pdf
《EN 15198-2007 en Methodology for the risk assessment of non-electrical equipment and components for intended use in potentially explosive atmospheres《潜在易爆环境中使用的非电气设备和部件的风险评估方法》.pdf》由会员分享,可在线阅读,更多相关《EN 15198-2007 en Methodology for the risk assessment of non-electrical equipment and components for intended use in potentially explosive atmospheres《潜在易爆环境中使用的非电气设备和部件的风险评估方法》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 15198:2007Methodology for the risk assessment of non-electrical equipment and components for intended use in potentially explosive atmospheresThe European Standard EN 15198:2007 has the status of a British StandardICS 13.230g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3
2、g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 15198:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 October 2007 BSI 2007ISBN 978
3、 0 580 55232 8National forewordThis British Standard is the UK implementation of EN 15198:2007.The UK participation in its preparation was entrusted to Technical Committee FSH/23, Fire precautions in industrial and chemical plant.A list of organizations represented on this committee can be obtained
4、on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date Com
5、mentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 15198August 2007ICS 13.230English VersionMethodology for the risk assessment of non-electrical equipmentand components for intended use in potentially explosiveatmospheresMthodes pour lvaluation du risque dinflammation desappareils et des compos
6、ants non lectriques destins tre utiliss en atmosphres explosiblesMethodik zur Risikobewertung fr nicht-elektrische Gerteund Komponenten zur Verwendung inexplosionsgefhrdeten BereichenThis European Standard was approved by CEN on 13 July 2007.CEN members are bound to comply with the CEN/CENELEC Inter
7、nal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member
8、.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are
9、 the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerla
10、nd and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15198
11、:2007: EEN 15198:2007 (E) 2 Contents Page Foreword3 Introduction .4 1 Scope 5 2 Normative references 5 3 Terms and definitions .6 4 General requirements6 5 Ignition risk assessment Procedure8 6 Documentation.13 Annex A (informative) Example of a reporting scheme for the ignition risk assessment .14
12、Annex ZA (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 94/9/EC 16 Bibliography 18 Figures Figure 1 Ignition risk assessment for design of equipment or component 8 Figure 2 Identification of ignition hazards . 10 Tables Table A.1 Reporting sc
13、heme with cross references to the documentation requirements of Clause 6 . 15 Table ZA.1 Correspondence between this European Standard and Directive 94/9/EC . 16 EN 15198:2007 (E) 3 Foreword This document (EN 15198:2007) has been prepared by Technical Committee CEN/TC 305 “Potentially explosive atmo
14、spheres - Explosion prevention and protection”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2008, and conflicting national standards shall be
15、withdrawn at the latest by February 2008. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mand
16、ate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive 94/9/EC. For relationship with EU Directive 94/9/EC, see informative Annex ZA, which is an integral part of this document. According to the CEN/CENELEC Internal Re
17、gulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Ne
18、therlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 15198:2007 (E) 4 Introduction The function of this type A standard (description of general principles) as defined in CEN Guide 414 is to describe principles for a consistent system
19、atic procedure for ignition risk assessment depending on Group II or Group I equipment. Annex A is informative and contains examples for ignition risk assessment. This European Standard does not provide means to prove the conformity of equipment categories. The procedure of ignition risk assessment
20、for the design of equipment and components lead to a defined safety level which allows categorisation according to the appropriate criteria. It is in both the manufacturers and users interest to establish a common methodology for achieving safety, reliability and efficacy in functioning and operatin
21、g equipment and components with respect to the ignition hazards. Thus, ignition risk assessment is a tool which provides the essential link between manufacturers and users, but only aspects that directly address manufacturers are incorporated. Integrated explosion safety is conceived to prevent the
22、formation of explosive atmospheres as well as sources of ignition and, should an explosion nevertheless occur, to halt it immediately and / or to limit its effects. In this connection, the manufacturer must take measures with respect to the potential ignition sources. In addition, equipment and comp
23、onent must be designed and constructed after due analysis of possible operating faults in order as far as possible to preclude dangerous situations taking the misuse which can reasonably be anticipated into account. Therefore it is absolutely necessary to conduct an ignition risk assessment process.
24、 For the equipment and components the identification of the potential ignition sources is the most relevant part of the ignition risk assessment. EN 15198:2007 (E) 5 1 Scope This European Standard specifies basic methodology used in achieving safety of equipment for intended use in potentially explo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN151982007ENMETHODOLOGYFORTHERISKASSESSMENTOFNONELECTRICALEQUIPMENTANDCOMPONENTSFORINTENDEDUSEINPOTENTIALLYEXPLOSIVEATMOSPHERES

链接地址:http://www.mydoc123.com/p-714845.html