EN 12829-2011 en Surface active agents - Preparation of water with known calcium and magnesium hardness《表面活性剂 已知钙质和镁硬度水的制备 》.pdf
《EN 12829-2011 en Surface active agents - Preparation of water with known calcium and magnesium hardness《表面活性剂 已知钙质和镁硬度水的制备 》.pdf》由会员分享,可在线阅读,更多相关《EN 12829-2011 en Surface active agents - Preparation of water with known calcium and magnesium hardness《表面活性剂 已知钙质和镁硬度水的制备 》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 12829:2011Surface active agents Preparation of water with known calcium and magnesium hardnessBS EN 12829:2011 BRITISH STANDARDNational forewordThis British Standard is the
2、 UK implementation of EN 12829:2011. It supersedes BS EN 12829:1998 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee CII/34, Methods of test for surface active agents.A list of organizations represented on this committee can be obtained on request to it
3、s secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2011 ISBN 978 0 580 66930 9 ICS 71.100.40 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard
4、 was published under the authority of the Standards Policy and Strategy Committee on 30 April 2011.Amendments issued since publicationDate T e x t a f f e c t e dBS EN 12829:2011EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12829 April 2011 ICS 71.100.40 Supersedes EN 12829:1997English Versio
5、n Surface active agents - Preparation of water with known calcium and magnesium hardness Agents de surface - Prparation dune eau de duret calcique et magnsienne dtermine Grenzflchenaktive Stoffe - Herstellung von Wasser mit bekannter Calcium- und Magnesiumhrte This European Standard was approved by
6、CEN on 26 February 2011. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national stand
7、ards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and no
8、tified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithua
9、nia, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2011 CE
10、N All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12829:2011: EBS EN 12829:2011EN 12829:2011 (E) 2 Contents Page Foreword 31 Scope 42 Normative references 43 Terms and definitions .44 Principle 45 Reagents .56 Apparatus .67 Procedure .
11、6Annex A (informative) Units used to express water hardness .8BS EN 12829:2011EN 12829:2011 (E) 3 Foreword This document (EN 12829:2011) has been prepared by Technical Committee CEN/TC 276 “Surface active agents”, the secretariat of which is held by AFNOR. This European Standard shall be given the s
12、tatus of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2011, and conflicting national standards shall be withdrawn at the latest by October 2011. Attention is drawn to the possibility that some of the elements of this document may be the
13、subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 12829:1997. The new edition includes the preparation of water with known magnesium hardness. According to the CEN/CENELEC Internal Regulations, the na
14、tional standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherland
15、s, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 12829:2011EN 12829:2011 (E) 4 1 Scope This European Standard specifies a method of preparing water of known calcium and magnesium hardness for use in testing surface active agents and p
16、roducts containing them. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. E
17、N ISO 385, Laboratory glassware Burettes (ISO 385:2005) EN ISO 648, Laboratory glassware Single-volume pipettes (ISO 648:2008) EN ISO 1042, Laboratory glassware One-mark volumetric flasks (ISO 1042:1998) EN ISO 3696:1995, Water for analytical laboratory use Specification and test methods ISO 1773, L
18、aboratory glassware Narrow-necked boiling flasks 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 water hardness Measure for the content of dissolved calcium and magnesium salts and, in special cases, salts of strontium and/or barium NOTE 1 Th
19、e unit of measurement of water hardness is the millimole per litre (mmol/l). 1 mmol/l of calcium hardness corresponds to 40,08 mg/l of calcium ions. 1 mmol/l of magnesium hardness corresponds to 24,31 mg/l of magnesium ions. NOTE 2 The equivalents for other degrees of hardness of water, as well as o
20、ther units used for measuring water hardness and the relationships between them, are given for information in Annex A. NOTE .3 Originally, the hardness of a sample of water was determined by measuring its power to destroy the foam formed by soap. This property is primarily due to the presence of cal
21、cium and magnesium, but salts of other metals, such as iron, aluminium and manganese, behave in a similar manner, although these seldom occur in natural waters. 4 Principle Preparation of a stock solution by dissolving an appropriate quantity of calcium chloride or magnesium chloride in water. Deter
22、mination of the calcium or magnesium ions in this stock solution by complexometric titration with the disodium salt of (ethylenedinitrilo)tetraacetic acid (EDTA) using a mixture of Mordant Black 11 (C.I. 14645) and methyl red as indicator. Preparation of dilute solutions, of the hardness required, b
23、y dilution of appropriate volumes of the stock solution. BS EN 12829:2011EN 12829:2011 (E) 5 5 Reagents 5.1 General WARNING Your attention is drawn to the regulations covering the handling of hazardous substances. Technical, organisational and personal protection measures should be observed. During
24、the analysis, unless otherwise specified, use only reagents of recognized analytical grade and have been checked in advance as to not interfere with the analytical results and water complying with grade 3 as defined in EN ISO 3696:1995. 5.2 Calcium chloride dihydrate (CaCl2.2H2O), (CAS number: 10035
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN128292011ENSURFACEACTIVEAGENTSPREPARATIONOFWATERWITHKNOWNCALCIUMANDMAGNESIUMHARDNESS 表面活性剂 已知 钙质 硬度

链接地址:http://www.mydoc123.com/p-706845.html