EN 1253-5-2017 en Gullies for buildings - Part 5 Gullies with light liquids closure《建筑物的沟槽-第5部分 带轻质液体的沟渠》.pdf
《EN 1253-5-2017 en Gullies for buildings - Part 5 Gullies with light liquids closure《建筑物的沟槽-第5部分 带轻质液体的沟渠》.pdf》由会员分享,可在线阅读,更多相关《EN 1253-5-2017 en Gullies for buildings - Part 5 Gullies with light liquids closure《建筑物的沟槽-第5部分 带轻质液体的沟渠》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 1253-5:2017Gullies for buildingsPart 5: Gullies with light liquids closureBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 1253-5:2017 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 1253-5:2017. Itsupersedes BS EN 125
2、3-5:2003 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee B/505/11, Waste Fittings For Sanitary Appliances.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all t
3、he necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2017. Published by BSI Standards Limited 2017ISBN 978 0 580 90753 1ICS 91.140.80Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Stand
4、ard was published under the authority of theStandards Policy and Strategy Committee on 28 February 2017.Amendments/Corrigenda issued since publicationDate Text affectedBS EN 1253-5:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1253-5 February 2017 ICS 91.140.80 Supersedes EN 1253-5:2003En
5、glish Version Gullies for buildings - Part 5: Gullies with light liquids closure Avaloirs et siphons pour btiments - Partie 5 : Siphons avec obturateur pour liquides lgers Ablufe fr Gebude - Teil 5: Ablufe mit Leichtflssigkeitssperren This European Standard was approved by CEN on 14 December 2016. C
6、EN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on ap
7、plication to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
8、Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, L
9、atvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre:
10、Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1253-5:2017 EBS EN 1253-5:2017EN 1253-5:2017 (E) 2 Contents Page European foreword . 3 1 Scope 4 2 Normative references 4 3 Terms and definition
11、s . 4 4 Types 4 5 Materials . 4 6 Requirements . 5 6.1 General 5 6.2 Inflow . 5 6.3 Security height . 5 6.4 Tightness 5 6.5 Maintenance 6 6.6 Flow rates . 6 7 Test methods 7 7.1 General 7 7.2 Closing ability and tightness . 7 7.3 Security height . 7 8 Marking . 7 9 Evaluation of conformity 8 Bibliog
12、raphy 9 BS EN 1253-5:2017EN 1253-5:2017 (E) 3 European foreword This document (EN 1253-5:2017) has been prepared by Technical Committee CEN/TC 165 “Wastewater engineering”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by pub
13、lication of an identical text or by endorsement, at the latest by August 2017, and conflicting national standards shall be withdrawn at the latest by August 2017. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN shall not be he
14、ld responsible for identifying any or all such patent rights. This document supersedes EN 1253-5:2003. This is the fifth part in EN 1253, a series of standards relating to different types of floor gullies, roof drains and access covers for drainage systems inside buildings. The EN 1253 series under
15、the main title Gullies for buildings actually consists of the following parts: Part 1: Trapped floor gullies with a depth water seal of at least 50 mm; Part 2: Roof drains and floor gullies without trap; Part 3: Evaluation of conformity; Part 4: Access covers; Part 5: Gullies with light liquids clos
16、ure. Since the latest versions of EN 1253-5 the most significant technical changes are the following: a) introduction of the new standards on trapped floor gullies with a depth of water seal of at least 50 mm (EN 1253-1) and evaluation of conformity (EN 1253-3); b) amendment of scope, classification
17、, requirements as well as methods of marking. According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Form
18、er Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 1253-5:2017EN 1253-5:2017 (
19、E) 4 1 Scope This European Standard specifies requirements for the design, construction, performance, application and marking as well as test methods of factory made gullies with a light liquid closure for buildings. Light liquid closures for buildings are applied to avoid uncontrolled discharge of
20、light liquids into drainage systems in case of emergency. This European Standard does not apply to installations for separation of light liquids covered by EN 858-1. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable
21、 for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1253-1:2015, Gullies for buildings - Part 1: Trapped floor gullies with a depth water seal of at least 50 mm EN 125
22、3-3, Gullies for buildings - Part 3: Evaluation of conformity 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 1253-1:2015 and the following apply. 3.1 gully with a light liquid closure trapped floor gully with closure device which prevents the light l
23、iquid from entering the drainage system 3.2 light liquid closure device which automatically closes the gully outlet when a certain level of light liquid is present 3.3 light liquid liquid with a density not greater than 0,95 g/cm3which is actually or practically insoluble in water and unsaponifiable
24、 Note 1 to entry: Such liquids are, e.g. petrol, diesel fuel, fuel oil. 4 Types Type A: Gully with an integrated light liquid closure with a flow rate in accordance with Table 1 for the unlimited use in gravity drainage systems. Type B: Gully with light liquid closure which is incorporated as an acc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN125352017ENGULLIESFORBUILDINGSPART5GULLIESWITHLIGHTLIQUIDSCLOSURE 建筑物 沟槽 部分 带轻质 液体 沟渠 PDF

链接地址:http://www.mydoc123.com/p-706427.html