EN 12412-2-2003 en Thermal performance of windows doors and shutters Determination of thermal transmittance by hot box method Part 2 Frames《窗 门和百叶窗热性能通过热箱法测定传热系数 第2部分 框架》.pdf
《EN 12412-2-2003 en Thermal performance of windows doors and shutters Determination of thermal transmittance by hot box method Part 2 Frames《窗 门和百叶窗热性能通过热箱法测定传热系数 第2部分 框架》.pdf》由会员分享,可在线阅读,更多相关《EN 12412-2-2003 en Thermal performance of windows doors and shutters Determination of thermal transmittance by hot box method Part 2 Frames《窗 门和百叶窗热性能通过热箱法测定传热系数 第2部分 框架》.pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 12412-2:2003 Thermal performance of windows, doors and shutters Determination of thermal transmittance by hot box method Part 2: Frames The European Standard EN 12412-2:2003 has the status of a British Standard ICS 91.060.50 BS EN 12412-2:2003 This British Standard, was publis
2、hed under the authority of the Standards Policy and Strategy Committee on 20 August 2003 BSI 20 August 2003 ISBN 0 580 42481 2 National foreword This British Standard is the official English language version of EN 12412-2:2003. The UK participation in its preparation was entrusted by Technical Commi
3、ttee B/540, Energy performance of materials, components and buildings, to Subcommittee B/540/1, European Standards for thermal insulation, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The Briti
4、sh Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Onli
5、ne. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsib
6、le international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover,
7、the EN title page, pages 2 to 42, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM EN124122 July2003 ICS91.0
8、60.50 Englishversion Thermalperformanceofwindows,doorsandshutters DeterminationofthermaltransmittancebyhotboxmethodPart 2:Frames Performancethermiquedesfentres,portesetfermetures Dterminationducoefficientdetransmissionthermiquepar lamthodedelabotechaudePartie2:Encadrements WrmetechnischesVerhaltenvo
9、nFenstern,Trenund AbschlssenBestimmungdes Wrmedurchgangskoeffizientenmittelsdes HeizkastenverfahrensTeil2:Rahmen ThisEuropeanStandardwasapprovedbyCENon2May2003. CENmembersareboundtocomplywiththeCEN/CENELECInternalRegulationswhichstipulatetheconditionsforgivingthisEurope an Standardthestatusofanation
10、alstandardwithoutanyalteration.Uptodatelistsandbibliographicalreferencesconcernings uchnational standardsmaybeobtainedonapplicationtotheManagementCentreortoanyCENmember. ThisEuropeanStandardexistsinthreeofficialversions(English,French,German).Aversioninanyotherlanguagemadebytra nslation undertheresp
11、onsibilityofaCENmemberintoitsownlanguageandnotifiedtotheManagementCentrehasthesamestatusasthe official versions. CENmembersarethenationalstandardsbodiesofAustria,Belgium,CzechRepublic,Denmark,Finland,France,Germany,Greece, Hungary,Iceland,Ireland,Italy,Luxembourg,Malta,Netherlands,Norway,Portugal,Sl
12、ovakia,Spain,Sweden,SwitzerlandandUn ited Kingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2003CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.EN124122:
13、2003EEN124122:2003(E) 2 Contents Foreword . 3 Introduction. 4 1 Scope 4 2 Normativereferences 4 3 Terms,definitions,symbols,unitsandsubscripts . 5 4 Principle . 6 5 Requirementsfortestspecimenandapparatus 6 5.1 General . 6 5.2 Surroundpanels. . 6 5.3 Specimenrequirementsandlocation . 6 5.3.1 Complet
14、eframesforwindowsanddoors. 6 5.3.2 Frameandsash,transomormullionprofilesections. 9 5.4 Calibrationpanels . 11 5.5 Temperaturemeasurementandbafflepositions . 11 6 Testprocedure . 13 6.1 General . 13 6.2 Calibrationmeasurements . 13 6.2.1 General . 13 6.2.2 Totalsurfaceresistance . 14 6.2.3 Surfaceres
15、istancesandsurfacecoefficientsofheattransfer. 15 6.2.4 Surroundpanelandedgeeffects . . 16 6.3 Measurementprocedurefortestspecimens 17 7 Testreport. . 19 AnnexA (normative) Determinationofenvironmentaltemperature . 21 A.1 General . 21 A.2 Environmentaltemperature. . 22 A.3 Meanradianttemperature 22 A
16、.4 Convectivesurfaceheattransfercoefficient . 23 AnnexB (normative) Linearthermaltransmittanceoftheedgezone 25 AnnexC (informative) Exampleofcalibrationtestandmeasurementofframespecimen. 32 C.1 Calibrationtestwithpanelsize1,23m 1,48m 32 C.2 Framespecimenmeasurement 38EN124122:2003(E) 3 Foreword This
17、documentEN124122:2003hasbeenpreparedbyTechnicalCommitteeCEN/TC89,“Thermalperformance ofbuildingsandbuildingcomponents“thesecretariatofwhichisheldbySIS. ThisEuropeanStandardshallbegiventhestatusofanationalstandard,eitherbypublicationofanidenticaltextor byendorsement,atthelatestbyJanuary2004,andconfli
18、ctingnationalstandardsshallbewithdrawnatthelatestby January2004. Thisstandardisoneofaseriesofstandardsoncalculationandmeasurementmethodsforthedesignand evaluationofthethermalperformanceofbuildingsandbuildingcomponents. AnnexesAandBarenormative.AnnexCisinformative. AccordingtotheCEN/CENELECInternalRe
19、gulations,thenationalstandardsorganizationsofthefollowing countriesareboundtoimplementthisEuropeanStandard:Austria,Belgium,CzechRepublic,Denmark,Finland, France,Germany,Greece,Hungary,Iceland,Ireland,Italy,Luxembourg,Malta,Netherlands,Norway,Portugal, Slovakia,Spain,Sweden,SwitzerlandandtheUnitedKin
20、gdom.EN124122:2003(E) 4 Introduction ThemethodgiveninthisEuropeanStandardprovidesdataonframesthatcanbeusedincalculationsoftheoverall thermalperformanceofwindowsanddoorsaccordingtoENISO100771, Thermalperformanceofwindows,doors andshuttersCalculationofthermaltransmittancePart1:Simplifiedmethod (ISO100
21、771). 1Scope ThisEuropeanStandardspecifiesamethod,basedonENISO8990andENISO125671,tomeasurethethermal transmittanceofframeandsashcomponentsofwindowsanddoors,includingmullionsandtransoms. Thethermalbridgingeffectofwindowordoorcomponents(handles,hinges,closingdevices,etc.)isincluded. Thetestprocedureis
22、designedtotakeintoaccountthewholedevelopedareaoftheframeorsashsurface,but excludestheinfluenceofthethermalbridgeintroducedthroughthespacerinsealedglazingunits. Edgeeffectsoccurringoutsideoftheperimeterofthespecimenareexcluded.Furthermore,energytransferdueto solarradiationisnottakenintoaccount,andair
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1241222003ENTHERMALPERFORMANCEOFWINDOWSDOORSANDSHUTTERSDETERMINATIONOFTHERMALTRANSMITTANCEBYHOTBOXMETHODPART2FRAMES

链接地址:http://www.mydoc123.com/p-706266.html