ECA TEP 150-1964 Relative Spectral Response Data for Photosensitive Devices ( S Curves)《感光设备的相对频谱响应数据》.pdf
《ECA TEP 150-1964 Relative Spectral Response Data for Photosensitive Devices ( S Curves)《感光设备的相对频谱响应数据》.pdf》由会员分享,可在线阅读,更多相关《ECA TEP 150-1964 Relative Spectral Response Data for Photosensitive Devices ( S Curves)《感光设备的相对频谱响应数据》.pdf(45页珍藏版)》请在麦多课文档分享上搜索。
1、EIA TEP150 64 m 3234600 O008403 7 m /- OCTOBER 1964 RELATIVE SPECTRAL RESPONSE DATA FOR PHOTOSENSITIVE DEVICES (ttsii CURVES) FORMULATED BY JEDEC ELECTRON TUBE COUNCIL JEDEC _ PUBLICATION -NO. 50 PRICE $2.00 i .: EIA TEPLSO 64 m 3234600 0008Ll04 9 m I d Explanatory Note . The curves and tables appea
2、ring in chia PublicatSon were pre- pared by JEDEC JT-4 Committee on Photosensitive Electron Tubes, in codperation with JEDEC JS-4 Committee on Photosensitive Semhonductor Devices, corresponds closely with the orLginal S-response registration data submitted by various manufacturers. In the cases of t
3、he S38, Sag, S20, and S2l. responaes, original tabular data used In preparing response curves for regiatration purposes was submitted by the registrant and used in the preparation of the tables appearing herein, For other S-responses, tabular data was obtained from the available registratLon curves
4、, 93.16 Committee developed permissible wavelength tolerance limits on the 10% and 300% pointa for the S4,. SlO, and SI8 responses and, such limits are indicated on the curves for these responses. The tabular and graphical data presented si, s3, SIC, Ss, s8, Sg, ao, sil, 512, sl3, s14, s35, sa6, sa7
5、, $-response nomencla.ture applies only to the relabive spectral reaponse of a photosenaitdve devSce, including the entrance window, nor to the chemical. and physical oomposition of that photosurface, or to the absolute .magnitude of the resuJtLng sensitivity. It does not refer to a specific .type o
6、f photosurface, ELECTRON IC Published by INDUSTRI ES ASSOCIATION Engineering Departmsnt 11 West B2nd Street, New York, N, Y, 136 1 EIA TEP150 b4 m 3234600 0008405 O m t Registered %Response Data Photosensitive Device Spectral Response Information a TABU3 OF CONTENTS SI s2 s3 s4 s5 s6 s7 S8 S9 SlO S1
7、J. s12 Sl3 Sl4 SI5 s3.6 sa7 si8 Sl9 s20 S2l s22 s23 Curve and Tabular Data (This S-designaton has been abandoned) Curve and Tabular Pata Curve and Tabular Data (with toleranoe limits) Curve and Tabular Data Curve and Tabular Data Curve and Tabular Data Curve and Tabular Data Curve and Tabular Data C
8、urve and Tabular Data (with tolerance li.m;lts) Curve and Tabular Data Curve. and Tabular Data Curve and Tabular Data Cyrve and Tabular Data Curve and Tabular Data Curve and Tabular Data Curve and Tabular Data Curve and Tabular Data (with tolerance limits) Curve and Tabular Data Curve and Tabular Da
9、ta Curve and Tabular Data Not En Use Curve and Tabular Data EIA TEP150 64 m 3234600 0008406 2 m b 3 SPECTRAL- SE N SITIVITY CHAR ACTERI STIC OF PHOTO SE N SITI VE DEVICE HAVING S-l RESPONSE FOR EQUAL VALUES OF RADIANT FLUX AT ALL WAVELENGTHS WAVELENGTH -ANGSTROMS I -2- - - EIA TEP150 64 3234600 0008
10、407 4 L i RELATIVE SPECTRAL RESPONSE S-l I Wavelength (A) Relative Wavelength (A) Relative (Angstroms ) Response Response- * 909 3100 3200 3300 3400 3500 3600 3700 3800 3900 4000 .270 ,520 .810 1,105 3. 350 1 480 1 a 350 1. 1.00 820 * ,561 7600 7900 8000 7 7800 00 971 .984 993 998 1.000 8100 8200 83
11、00 8500 8400 4100 4200 4300 4400 4500 .360 8600 8700 8800 8900 goo0 * 929 * 903 .874 .841 e 803 2-71 761 716 .670 ,622 4600 4700 4800 4900 so00 170 174 . a82 9100 9200 9300 9400 9500 9600 9700 9800 9900 10000 194 209 227 .248 .271 295 .321 573 53.00 5200 5300 5400 5500 5600 5700 5800 5900 6000 * 329
12、 e 349 10100 378 10200 10500 * 439 .471 .408 10300 10400 .285 , 208 .245 9 175 .a48 a 504 539 10600 10700 10800 logo0 11000 11100 11200 11300 11400 11500 p 124 .j04 ,088 b 074 .063 6100 6200 6300 6500 6600 6700 6800 6900 7000 6400 575 61.1 b 647 ,683 . I 718 4 o53 .036 e 029 .023 b 044 .017 .012 .00
13、8 005 b 002 753 787 ,820 b 851 ,881 909 .* 933 ,954 ; 11600 11700 11800 11goo 12000 7100 7200 7300 7400 7500 EIA TEP150 b4 m 3234b00 0008408 b m * a WAVELENGTH - ANGSTROMS - 4- - . I * - EIA TEPLSO b4 W 3234b00 0008409 8 W RELATIVE SPECTRAL RESPONSE S-3 Wavelength (A ) Relative a (Angstroms Response
14、 Wavelength (A) Relative (Angstroms) Response 3600 3700 3800 3900 4000 4100 4200 4300 4400 4500 4600 4700 4800 49 O0 5000 5100 5200 5300 5400 5500 5600 5700 5800 5900 6000 6100 6200 6300 6500 6400 700 ,860 .930 .965 - 985 997 998 ,993 -982 1.00 .84 .81 * 78 8 75 .72 b 69 ,665 .64 e 615 b 59 565 54 *
15、 515 .492 , 469 -5- 6600 6700 6800 6900 7000 7100 7300 7400 7500 7200 7600 7700 7800 7900 8000 8100 8200 8300 8500 8400 8600 8700 8800 8900 goo0 ,446 ,424 .402 .34 .32 ,301 ,282 .264 ,246 .228 .21 ,192 8 175 I i58 .14 .122 ,105 .088 . O70 .052 . o35 02 .o EIA TEP150 64 = 3234b00 0008LiLO 4 3 SPECTRA
16、L- SENSITIVITY CHARACTERISTIC OF PHOTO- SENSITIVE DEVICE HAVING S-4 RESPONS a FOR EQUAL VALUES OF RADIANT FLUX AT ALL WAVELENGTHS WAVELENGTHS - ANGSTROMS -6- * EIA TEPLSO b4 m 3234b00 00084LL b m RELATIVE SPECTRAL RESPONSE S-4 Wavelength (A ) Relative O (Angstroms ) Re sp ons e ,048 .260 *915 955 98
17、1 995 9.009 EIA TEP150 b4 m 3234b00 0008432 8 m SPECTRAL- SENSITIVITY CHARACTERISTIC OF PHOTO- SENSITIVE DEVICE HAVING S-5 RESPONSE FOR EQUAL VALUES OF RADIANT FLUX AT ALL WAVELENGTHS WAVELENGTH - ANGSTROMS EIA TEP150 b4 3234680 0008433 T RELATIVE SPECTRAL RESPONSE S-5 c Wavelength (h) (Angstroms) 3
18、000 3100 3200 3300 3400 3500 3600 3800 3700 3900 4000 4100 4200 4300 4400 4500 4600 . 4700 4800 4900 5000 5100 5200 5300 5400 . 5500 5600 5700 5800 5900 6000 Relative Response .goo ,940 970 ,990 1 .o00 ,990 975 ,950 925 ,900 ,870 .840 .810 ,780 ,750 ,715 680 ,645 .610 b 575 535 495 450 ,405 .360 i 3
19、10 ,260 ,210 i65 .130 ,100 6100 a 070 6200 ,050 6400 . , 025 6300 b o35 6500 ,015 6600 ,010 67 00 ,006 6800 i O03 6900 001 7000 ao , -. % -9- EIA TEP350 b4 = 3234b00 0008434 3 I t 1 SPECTRAL-SENSIT IV ITY CHARACTERISTIC OF PHOTO- SENSITIVE DEVICE HAVING S-6 RESPONSE FOR EQUAL VALUES OF RADIANT FLUX
20、AT ALL WAVELENGTHS WAVE L E N GT H S -ANGSTROMS - 10- - EIA TEP350 64 E 3234600 0008435 3 E - RELATIVE SPECTRAL RESPONSE S-6 Wavelength (h) (Angstroms) 2100 2200 2400 2300 2500 2600 2700 2800 2900 3000 3100 3200 3600 3700 3800 3900 4000 4100 4200 4300 4400 Relative. Response .10 27 46 : 64 .81 .93 o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECATEP1501964RELATIVESPECTRALRESPONSEDATAFORPHOTOSENSITIVEDEVICESSCURVES 感光 设备 相对 频谱 响应 数据 PDF

链接地址:http://www.mydoc123.com/p-704564.html