ECA 480-1981 Toggle Switches《拨动开关》.pdf
《ECA 480-1981 Toggle Switches《拨动开关》.pdf》由会员分享,可在线阅读,更多相关《ECA 480-1981 Toggle Switches《拨动开关》.pdf(27页珍藏版)》请在麦多课文档分享上搜索。
1、A 480 81 m 323VbOO 0070957 8 m . O kN#IIIA RI-180-1081 APPROYIED JULY 6,1981 P TOGGLE SWITCHES I EIA STANDARD a Engineering Department ECTRONIC INDUST RS-480 JULY 1981 RIES ASS OCIATIOH EIA 480 BL m 3234b00 0070958 T m r - NOTICE EIA Engineering Standards and Publications are designed to serve the p
2、ublic interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards an
3、d Publications shall not in any respect preclude any member or non-member of EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than EIA members, whether
4、the standard is to be used either domestically or internationally. Recommended Standards and Publications are adopted by EIA without regard to whether or not their adoption may involve“ patents on articles, materials, or processes. By such action, EIA does notassume any liability to any patent owner
5、, nor does it assume any obligation whatever to parties adopting the Recom- mended Standard or Publication. This Standard contains the major technical content of International Electro Technical Commission recammendation - 131-1, Toggle Switches, 1962. It differs from IEC recommendation 131-1 in cert
6、ain important respects, as given in Appendix B hereto. These differences have been called to the attention of the U.S. Committee of Experts for IEC Technical Committee 48C, Switches, and resolution of these differences will be sought in future meeting of TC48. . Published by ELECTRONIC INDUSTRIES AS
7、SOCIATION Engineering Department 2001 Eye Street, N.W. Washington, D.C. 20006 Copyright 1981 ELECTRONIC INDUSTRIES ASSOCIATION All rights reserved PRICE: $7.50 Printed in U.S.A. e Paraqraph Introduction EIA 4BO 81 3234600 0070959 II 1.0 2.0 3.0 4.0 5.0 6.0 7.0 TABLE 1: TABLE 2: RS-480 TOGGLE SWITCHE
8、S TABLE OF CONTENTS Paqe 1 cope Applicable Documents Definitions Design Requirements Performance Requirements Qualification Tests Quality Conformance Inspection Qualification Tests Quality Conformance Inspection 2 2 3-4 5-6 7-16 17 19 18 19 TABLE Al: Ctandard Switching Characteristics 21 FIGURE Al:
9、Terminal Locations 20 FIGURE A2: Locking Combinations 22 APPENDIX A: Standard Switching Circuits 20 23-24 APPENDIX 6: Comparison with IEC Publication 131-1 - -1- EIA 480 81 3234b00 0030960 8 W RS-480 Page 1 TOGGLE SWITCHES (From EIA Standards Proposal No. 1242, formulated under the cognizance of EIA
10、 P-5.8 Working Group on Slide, Rocker and Toggle Switches.) INTRODUCTION This EIA Standard was formulated for the purpose of: (a) (b) Eliminating misunderstandings or confusion between manufactureres and .buyer with Promoting interchangeability of toggle switches, and respect to product performance
11、values. This Standard applies to toggle switches intended to be installed in control circuits or au- xiliary circuits of electronic equipment or other equipment employing simiIar techniques. This Standard must be used in conjunction with a detail specification which defines specific values for the p
12、erformance of the Standard and may add, delete or modify the requirements of the Standard. The buyer may utilize the Detail specifications issued by EIA, or, if necessary, prepare his own detail specification which references this Standard. The EIA Detail Specifications assign a unique part number t
13、o each particular switch configuration covered by the Detail Specification. This part number is adequate to use for procurement of a standard switch. Within the context of this EIA Standard, a standard switch is considered to be a switch which is described by an EIA Detail Specification, and a non-s
14、tandard switch is considered to be a switch which is not described by an IA Detail Specification. When a description of a non-standard switch is required, the manufacturer or buyer should prepare a detail specification which fully describes the non-standard switch. If the required non-standard switc
15、h differs from the switch types described by EIA Detail Specifications, a complete detail specification should be prepared, If the required non-standard switch is similar to the switch types described by the EIA Detail Specification, a detail specification may be prepared by referencing the part num
16、ber of the standard switch and specifying the difference required from the standard switch. EIA 480 81 m 323460 00709b1 T m RS-480 Page 2 1.0 2.0 SCOPE These recommendations relate to toggle switches for use in equipment for electrical and electronic devices, including switches necessary to connect
17、the supply mains. These switches are not intended to be used in electrical distribution systems. Switches covered by these recommendations have a rated voltage not exceeding 600 volts and a rated current not exceeding 25 amperes (dc or rms values), APPLICABLE DOCUMENTS The following documents of the
18、 issue in effect form part of the standard to the extent specified. 2.1 2.2 2.3 2.4 2.5 International Electrotechnical Commission Publication 131-1 Toggle Switches, Part I, General Requirements and Measuring Methods. GSA Standards (Government Services Administration) FED-STO-28 Screw Thread Standard
19、s for the Federal Government. American National Standards (ANSI) 2 310.1 Determining Resistance of Synthetic Polymeric Materials to Fungi. Electronic Industries Association (EIA) RS-186-9E METHOD 9: Solderability RS-186-E I Standard Test Methods for Passive Electronic Component Parts - General Instr
20、uctions and Index of Tests RS-448 Standard Test Methods for Electromechanical Switches Underwriters Laboratories U.L. 94 Tests for Flammability of Plastic Materials. EIA 480 81 = 3234b00 0090962 1 . RS-480 Page 3 3.0 DEFINITIONS 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 3.11 3.12 Toqqle Switch: A swi
21、tch manually operated by moving a projecting lever through a small arc. Posit ion: (A mechanical location referring to actuator position.) A setting of the lever which results in a particular circuit condition. maintained when the externally applied actuating force is removed. A position may be mome
22、ntary or Operatinq Force: . The externally applied force required to move the switch actuator (lever or rocker) from one position to an adjacent position. Poles: The number of separate circuits which can carry current at the same time. Make Before Break: The open contacts close before the closed con
23、tacts open when the switch actuator is moved from one position to another. Break Before Make: The closed contacts open before the open contacts close when the actuator is moved from one position to another. Panel Sealed: When properly mounted, the switch prevents the entrance of liquids through the
24、panel mounting hole. Environmentally Sealed: The switch enclosure is sealed to prevent the entrance of the ambient environ- ment into the switching mechanism. Hermetically Sealed: The switch enclosure is sealed to be gas tight by fusion of glass or ceramic to metal, or metal to metal. Throw: Any tog
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECA4801981TOGGLESWITCHES 拨动 开关 PDF