DLA MS90386 REV D-2009 INDICATOR ELAPSED TIME ELECTROCHEMICAL (MERCURY) 115 VOLT AC 50 2400 Hz 28 VOLT DC OR 5 VOLT DC.pdf
《DLA MS90386 REV D-2009 INDICATOR ELAPSED TIME ELECTROCHEMICAL (MERCURY) 115 VOLT AC 50 2400 Hz 28 VOLT DC OR 5 VOLT DC.pdf》由会员分享,可在线阅读,更多相关《DLA MS90386 REV D-2009 INDICATOR ELAPSED TIME ELECTROCHEMICAL (MERCURY) 115 VOLT AC 50 2400 Hz 28 VOLT DC OR 5 VOLT DC.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to Defense Supply Center Richmond, ATTN: DSCR-VEB, 8000 Jefferson Davis Highway, Richmond, VA 23297-5616 or e-mailed to STDZNMGTDLA.MIL. Since contact information can change, you may want to verify the currency of this address
2、information using the ASSIST database at http:/assist.daps.dla.mil. AMSC N/A FSC 6645 INCH-POUNDS MS90386D 20 April 2009 SUPERSEDING MS90386C(AS) 7 October 1987 DETAIL SPECIFICATION INDICATOR, ELAPSED TIME, ELECTROCHEMICAL (MERCURY) 115 VOLT AC 50/2400 Hz, 28 VOLT DC OR 5 VOLT DC Inactive for new de
3、sign after 23 July 1997. This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this Military Specification Sheet and MIL-DTL-81219. 1 PART OR IDENTIFYING NUMBER (PIN) 1.1 PIN.
4、The PIN is formed as follows: MS90386 - X Part description number per table I Specification number 1.2 H designation. Indicators with an H designation are for horizontal mounting. Unless otherwise specified, a citation to a dash number represents both non-H and H designated indicators. Provided by I
5、HSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS90386D 2 1.3 Substitutions. -1 through -12 indicators are replaceable by the equivalent -100 series indicator (i.e. a -1 indicator is replaceable by a -101 indicator). The units are mechanically, electrically and
6、dimensionally the same except for the mechanical and thermal shock limits as given in table I. 2 REQUIREMENTS 2.1 Dimensional. The indicator shall conform to the dimensions given in figures 1 through 5 as required. a. All dimensions are in inches. b. Tolerances, unless otherwise specified, are 0.015
7、 2.2 Weight. The indicator shall not exceed 0.1 ounce. 2.3 Time range. Total readout shall be in accordance with table I. The time scale shall be 0.650 inches long and have 20 equal divisions as shown in figure 1. 2.4 Operating temperature range. -20C to 85C. The indicator may also be used in equipm
8、ent with an operating range of -55C to 85C with accurate operation above -20C. 2.5 Storage temperature range. -80C to 85C. 2.6 Power consumption. Power consumption at the rated voltage per table I shall not exceed 50 milli-watts. 2.7 Life accuracy. Accuracy shall be 3% for -1 through -12 and 5% for
9、-101 through -112 from -20C to 85C over the following conditions: MS90386-1-3-5-7-101-103-105-107: 115Vac 13Vac, 50 HZ to 2400 Hz MS90373-2-4-6-8-102-104-106-108: 23Vdc to 29Vdc MS9.386-9-10-11-12-109-110-111-112: 4.95Vdc to 5.05Vdc 2.8 Color. The indicators shall be of the following colors: a. Face
10、plate - black b. Numerals - white on black background c. Scale - black on white background 2.9 Test terminal cap. The test terminal cap shall be made of polytetrafluroethylene (PTFE). 3 TESTS AND CHECKS 3.1 Mechanical shock. Indicators shall be tested in accordance with MIL-STD-202, Method 213. Test
11、 conditions shall be: a. -1 through -12 - condition A (50g, 11ms) b. -101 through -112 - condition C (100g, 6ms) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS90386D 3 3.2 Thermal shock. Indicators shall be tested in accordance with MIL-STD-202,
12、Method 107 for the following number of cycles: a. -1 through -12 - 5 cycles b. -101 through -112 - 10 cycles 3.3 Operational check. Each indicator shall have the following operational checks performed. 3.3.1 Indicating cell. At 25C and the indicator energized at its rated voltage, the voltage betwee
13、n the test terminal (center terminal) and the input/test terminal (terminal nearest “+” sign) shall be measured. The measured voltage shall be less than the “V Cell Maximum” as shown in table I. CAUTION: Do not short the test terminal to the input terminal. Accidental momentary grounding or the appl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMS90386REVD2009INDICATORELAPSEDTIMEELECTROCHEMICALMERCURY115VOLTAC502400HZ28VOLTDCOR5VOLTDCPDF

链接地址:http://www.mydoc123.com/p-697891.html