1、AMSC N/A FSC 5950 INCH-POUND MIL-PRF-27/348C 13 July 2012 SUPERSEDING MIL-PRF-27/348B 17 January 1986 PERFORMANCE SPECIFICATION SHEET TRANSFORMERS, POWER, 270 VOLTAMPERES, 3-PHASE This specification is approved for use by all Departments and agencies of the Department of Defense. The complete requir
2、ements for procuring the transformer described herein shall consist of this document and the latest issue of specification MIL-PRF-27. (For dash numbers 01 through 06) Primary (For dash nos. 01 thru 06) WYE, 115 V to Com 1,2,3 line 4 Com WYE, 200 V L-L 1,2,3 (For dash numbers 07 through 18) SECONDAR
3、Y WYE, L Com Connect 6-8-10, Load 5-6, 7-6, 9-6 DELTA, L-L Connect 6-7, 8-9 5-10, Load 5,7,9 WYE, L-L Connect 6-10, 8-10, Load 5,7,9 PRIMARY (For dash nos. 07 thru 12) Delta, 115 V L-L 1,2,3 PRIMARY (For dash nos. 13 thru 18) Delta, 200 V L-L 1,2,3 CIRCUIT DIAGRAMS FIGURE 1. Dimensions and configura
4、tions. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-27/348C 2 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .04 (1.0 mm). 4. Marking shall be o
5、n top and side of case. 5. Terminal 4 is missing for dash nos. 07 thru 18. FIGURE 1. Dimensions and configurations - Continued. Inches mm .010 0.25 .02 0.5 .090 2.29 .1640 4.165 .20 .25 5.1 6.4 .28 7.1 .40 10.2 .82 20.8 1.22 31.0 1.99 50.6 2.50 63.5 3.04 77.2 3.15 80.0 3.69 93.7 Provided by IHSNot f
6、or ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-27/348C 3 REQUIREMENTS: (When numbers in parentheses, i.e., (1-2) are used, they indicate the winding and the extreme terminals of the winding.) Electrical ratings: Primary voltage at 400 20 Hz Wye connected (dash
7、numbers 01 through 06). (1-4): 115 V ac. (2-4): 115 V ac. (3-4): 115 V ac. (1-2): 200 V ac. (1-3): 200 V ac. (2-3): 200 V ac. Delta connected (dash numbers 07 through 12) (1-2): 115 V ac. (1-3): 115 V ac. (2-3): 115 V ac. Delta connected (dash numbers 13 through 18) (1-2): 200 V ac. (1-3): 200 V ac.
8、 (2-3): 200 V ac. Secondary voltage: See table I. Secondary current: See table I. Working voltage: 535 volts peak, maximum. Design and construction: Dimensions and configuration: See figure 1. Duty cycle. Continuous. Case: Epoxy fiberglass. Terminals: Solderable turret type. Height: 0.28 .040 inch (
9、7.11 1.02mm). Diameter: 0.090 .010 inch (2.29 0.25mm). Weight: 2.8 pounds, maximum. Operating temperature range. -55 to +130C. Altitude: 70,000 feet. Terminal strength: MIL-STD-202, method 211, test condition A, 5 pounds. Dielectric withstanding voltage (Secondary connected wye): At atmospheric pres
10、sure (each winding): 1500 volts rms. At barometric pressure (each winding): 670 volts rms Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-27/348C 4 Electrical characteristics: Rated load: With rated voltage across the primary at 400 Hz, the v
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF27348C2012TRANSFORMERSPOWER270VOLTAMPERES3PHASEPDF

链接地址:http://www.mydoc123.com/p-692735.html