DLA MIL-PRF-1 1596B-1998 ELECTRON TUBE POWER TYPE 8116《电源型8116电子管》.pdf
《DLA MIL-PRF-1 1596B-1998 ELECTRON TUBE POWER TYPE 8116《电源型8116电子管》.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-1 1596B-1998 ELECTRON TUBE POWER TYPE 8116《电源型8116电子管》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-PRF-L/L59bB 0b 20b774 25Y I Parameter: Ef F Eb Unit: V ac MHz Vdc Maximum: 13.251265 30 1,000 AB, SSB fl 0% (Note 2) Test Conditions: 13.25126.5 - - - 600 Ecl Ec2 Ehk Ib IC1 Vdc Vdc Vdc mAdc mAdc -175 360 +lo0 220 10 -_ Adj 250 O 40 I INCHPOUND I MIL-PRF-l/1596B(NAVY) Parameter: Unit: Maximum:
2、AB, SSB (Note 2) Test Conditions: 11 Auqust 1998 SUPERSEDING Pgl Pg2 Pp Pi T tk W W W W “G (Note 3) sec (min) 2x1 7 2x30 200 30 120 _- -_ - _ - -_- MlL-E-l/1596A(NAVY) 30 October 1974 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, POWER TYPE 8116 This specification is approved for use by Naval Elect
3、ronic Systems Command, Department of the Navy, and is available for use by all Departments and Agencies of the Department of Defense. The requirements for procuring the electron tube described herein shall consist of this document and the latest issue of Specification MIL-PRF-I. DESCRIPTION: Double
4、tetrode See figure 1 Mounting position - - - Vertical, base up or down; horizontal with anode pins in a horizontal plane. Weight - - - - - - - - - - 2.5 ounces nominal (70.9 grams) GENERAL Qualification - Not required AMSC N/A DISTRIBUTION STATEMENT A. Approved for pubic release; distribution is unl
5、imited. Page 1 of 8 FSC 5960 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-L/159bB I 9979906 20b7750 T7b I nspection %formance inspection t = 180 If = 13.25 V; t = 300 Ecl/lb = 1 O mA dc; Rp = 2,000 ohms Angle = 30“ Eb = 250 V dc; Ecl = -85
6、 V dc Paralleled operation class AB1 amplifier; Ef = 26.5 V ac; F = 15 MHz (rnax); Ecl/lb = 55 mA dc; lc2 = 30 mA dc (max) After 5 minutes, power output (1) Ef = 23.9 V ac; power output (1) Eb = 1,000 V dc; Ec2 = 270 V dc; Acceptance Level 1 .o 1 .o 1 .o 1 .o 1 .o 0.65 nspection -eve1 or ode II II I
7、I II II II jymbol IS IC2 EC1 IC1 If - Ec 1 Ib Po APO t APO Ef CgP Cin Gout - Limit Min - 1.5 -_ -25 - 760 - - -40 130 0.050 9.4 2.6 - - Limit Max - _- 6.0 -35 -6.0 1,260 - - 3,000 -52 10 -_ 10 15 0.080 11.8 3.7 - f Unit a mA dc V dc fi dc mA ac - mV ac V dc ClA dc W (usehil) YO YO PF PF PF See notes
8、 at end of Table I. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-3/359bB E 9999906 2067753 902 nspection Conformance inspection. w Life test Lit-test end points: Peak emission Power output (1) Electrode current (grid) Vibration NOTES: 1.
9、 2. 3. 4. 5. 6. 7. 8. 9. 1 o. 11. Method Notes 3,8 11 MIL-PRF-1/15968( NAVY) Table 1. Testina and Inspection. -Continued. Conditions Group C; power output (1); t = 500 hours except: Ecl/lb = 50 mA dc; Ec2=250Vdc F = 50 Hz; t = 900; no voltages Acceptance Level -Ti- Symbol Limit Unit -_- a W (useful)
10、 fi dc _- This test is to be the first test performed at the conclusion of the holding period. Class AB linear RF amplifier single sideband suppressed carrier operation, both sections in parallel. Maximum glass and seal temperature shall be 250C. When operating the tube at maximum ratings, with forc
11、ed air cooling, it is necessary to cool both the lateral bulb surface as well as the anode pin seals by directing the flow of air toward the top and sides of the bulb. In most cases, approximately 20 cfm is sufficient. At reduced ratings, the use of heat sink is permissible. However, regardless of t
12、he type of cooling being used, the degree of cooling shall be determined by direct temperature measurement of both the seals and the bulb. Power output is total power at drive frequency delivered to load. Drive power is not subtracted from total output. Output circuit tuned for maximum power output.
13、 Read each unit separately. Grid (1) of section not under test shall be connected to -1 O0 V dc. Tie both anodes and the screen together. The pulse duration measured at 5 percent of the maximum value shall not be less than 3 p. At 50 percent amplitude, the duration shall be less than 2 YS. The appli
14、ed voltage shall have a maximum repetition rate such that the duty cycle, based on the pulse length measured at 50 percent amplitude, shall not exceed 0.0002 (0.02 percent). The test shall be duplicated on each unit separately. The unit not under test shall be tied to ground. Shielding shall be in a
15、ccordance with figure 2. Operation as class “AB1“ amplifier, Q = 10 minimum. Power output is total power at drive frequency delivered to load. Drive power is not subtracted from total output. Output circuit tuned for maximum power output. Drive to true “O“ bias point condition which shall be met aft
16、er all tuning is completed. Ef = 13.25, Eb = 800 V dc, Ec2 = 325 V dc, anodes and grids (1) in parallel, vary Ecl for Ib = 45 mA dc (total, both sections). These test conditions exceed the absolute maximum ratings and operation shall be limited to 5 minutes maximum “ony time followed by an “off“ tim
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF11596B1998ELECTRONTUBEPOWERTYPE8116 电源 8116 电子管 PDF

链接地址:http://www.mydoc123.com/p-692003.html