1、AMSC N/A FSC 5930 INCH-POUND MIL-DTL-3786/2G 26 January 2011 SUPERSEDING MIL-DTL-3786/2F 19 November 2004 DETAIL SPECIFICATION SHEET SWITCH, ROTARY, OPEN CONSTRUCTION, AMPERE, STYLE SR02 Inactive for new design after 8 March 1999 This specification is approved for use by all Departments and Agencies
2、 of the Department of Defense. The requirements for acquiring the switch described herein shall consist of this specification sheet and MIL-DTL-3786. FIGURE 1. Style SR02 switch. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3786/2G 2 NOTES
3、: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .015 (0.38 mm). 4. The number of sections is optional. 5. Nonturn device as shown is not applicable to S construction switches. 6. Shaft-flat angle 90 is the angle
4、 between a line through the center of the shaft and center of the nonturn device and another line through the center of the shaft and perpendicular to the shaft flat. 7. Shaft shown in maximum counterclockwise position for switches with stop and with switch in position number 1 for switches without
5、stop. 8. For allowable variations, see MIL-DTL-3786 ordering data. 9. Front plate design optional provided it falls within the maximum O.D. of the section dimension referenced. FIGURE 1. Style SR02 switch - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without licen
6、se from IHS-,-,-MIL-DTL-3786/2G 3 FIGURE 2. Circuit diagrams viewed from front or knob end with switch in extreme counterclockwise position. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3786/2G 4 FIGURE 2. Circuit diagrams viewed from fron
7、t or knob end with switch in extreme counterclockwise position - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3786/2G 5 FIGURE 2. Circuit diagrams viewed from front or knob end with switch in extreme counterclockwise position -
8、Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3786/2G 6 FIGURE 2. Circuit diagrams viewed from front or knob end with switch in extreme counterclockwise position - Continued. Provided by IHSNot for ResaleNo reproduction or networ
9、king permitted without license from IHS-,-,-MIL-DTL-3786/2G 7 REQUIREMENTS: Dimensions and configurations: See figures 1 and 2. Angle of throw: 18, 22.5, 30, 36, 25.7, 45, 60, and 90. Terminals: The terminal tabs shall be bent at an angle of 60 15 degrees from the plane of the section. When flat ter
10、minals are required, the dimensions shall be as shown on figure 1. Rotational torque: The minimum and maximum values of torque determined for shaft rotation shall be within the limits specified in table I. TABLE I. Rotational-torque limits. Temperature Torque (pound-inch) Minimum Maximum Room 1.5 6
11、Minimum 1.5 8 Construction type: See table IV. Number of poles per deck: See table VI. Number of positions: See table VI. Life (rotational): The test loads for the applicable circuit conditions shall be as specified in table II. Each of the loads, specified for the applicable environmental condition
12、, shall be switched by at least one rotor contact of the switch. TABLE II. Electrical loads. Environmental condition Inductive load Resistive load Milliamperes Volts, dc Milliamperes Volts At atmospheric pressure 50 28 500 250 50 28 V dc 115 V rms 300 V rms At reduced barometric pressure - - 350 100
13、 28 V dc 115 V rms Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3786/2G 8 Dielectric withstanding voltage: The applicable test voltage specified in table III shall be applied between the general switch elements. TABLE III. Dielectric-test
14、voltages. Altitude Test voltage Volts, rms At atmospheric pressure 1,000 At reduced barometric pressure 400 Mounting hardware: Each switch shall be supplied with 1 each hexagon nut in accordance with MS25082-20 or equivalent, and one internal-tooth lockwasher in accordance with NASM35333-42 or equiv
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL37862G2011SWITCHROTARYOPENCONSTRUCTIONAMPERESTYLESR02PDF

链接地址:http://www.mydoc123.com/p-690656.html