1、AMSC N/A FSC 8130 MIL-DTL-3241F 6 January 2010 SUPERSEDING MIL-R-3241E 9 July 1985 DETAIL SPECIFICATION REELS, CABLE (REELS DR-5( ), DR-7( ), DR-B( ), RC-453( )/G, RL-159( )/U) INACTIVE FOR NEW DESIGN AFTER 25 FEBRUARY 1998 This specification is approved for use by all Departments and Agencies of th
2、e Department of Defense. 1. SCOPE 1.1 SCOPE. This specification covers five types of steel reels for use in storing and transporting field wire and cable, designated as reels DR-5( ), DR-7( ), DR-8( ), RC-453( )/G and RL-159( )/U (see 6.4). 2. APPLI CABLE DOCUMENTS 2. 1 General. The documents listed
3、 in this section are specified in section 3, 4, or 5 of this standard. This section does not include documents cited in other section of this standard or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users ar
4、e cautioned that they must meet all specified requirements of documents cited in section3, 4, or 5 of this standard, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this sp
5、ecification to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-C-10578 - Corrosion Removing and Metal Conditioning Compound (Phosphoric Acid Base) MIL-W-12332 - Welding, R
6、esistance, Spot, Seam, and Projection, for Fabricating Assemblies of Low- Carbon Steel MIL-DTL-14072 - Finishes for Ground Based Electronic Equipment MIL-DTL-53039 - Coatings, Aliphatic Polyurethane, Single Component, Chemical Agent Resistant Comments, suggestions, or questions on this document shou
7、ld be addressed to Defense Supply Center Philadelphia (DSCP), ATTN: DSCP-NASA, 700 Robbins Avenue, Philadelphia, PA 19111-5096 or e-mail to dscpg however, final acceptance and shipment will be withheld until the group C reinspection results have shown that the corrective action was effective (see 6.
8、3). 4.3.2.4 Reinspection of conforming group C sample units. Unless otherwise specified, sample units which have been subjected to and passed group C inspection may be accepted on contract, provided that they are resubjected to and pass group A inspection after repair of all visible damage. 4.4 Work
9、manship. The reels shall be given a thorough visual and mechanical inspection to ascertain that the material, construction, and welding are in accordance with applicable requirements (see 3.12). 4.5 Test for fit on axle. Reels DR-5( ), DR-7( ), RC-453( )/G and RL-159( )/U shall be tested with an axl
10、e 1-1/32 inch +0 -1/64 by 1-1/32 inch +0 -1/64 to insure compliance with 3.4. Reel DR-8( ) shall be tested with an axle 11/32 inch +0 -1/64 by the 11/32 inch +0 -1/64 to insure compliance w1th 3.4. 4.6 Alignment tests. 4.6.1 Reel head. The requirements of 3.5 shall be met for reels DR-5( ), DR-7( ),
11、 RC-453( )/G and RL-159( )/U when axle, 1-1/32 inch +0 -1/64 by 1-1/32 inch +0 -1/64 is inserted through the center of reels. The same shall apply for reel DR-8( ) except that the axle size shall be 11/32 inch +0 -1/64 by 11/32 inch +0 -1/64. 4.6.2 Plate alignment on reel RC-453( )/G. The requiremen
12、ts of 3.5.1 shall be met using the drum as a reference. 4.7 Vibration test. The reels shall be subjected to the test of 4.7.1 through 4.7.4. During vibration the unlit shall be clamped in its normal operating position on a vibration table that can be controlled to within 10 percent of specified freq
13、uencies and amplitudes. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MILDTL3241F 8 4.7.1 Direction of vibration. The reels shall be vibrated successively, over the specified ranges of applied frequencies, in three mutually perpendicular directions
14、 parallel to the edges of the reels. 4.7.2 Rate of change of vibration frequency. The frequency of the applied vibration shall be varied uniformly at a rate of approximately one Hz per minute. 4.7.3 Amplitude and frequency of applied vibration. The amplitude (one-half of the total excursion) of the
15、vibration table and the frequency range shall be in accordance with the following: Frequency of vibration (hz) Amplitude of vibration (in) 10 to 33 Horizontal 0.020 Vertical 0.030 4 7.4 Duration of test. The reels shall be vibrated for at least six hours, two hours in each of the three directions sp
16、ecified in 4.7.1. 4.7.5 At the conclusion of the tests, the reels shall be examined for compliance with 3.6. 4.8 Drop test. The drop test shall be performed on the reels specified in 4.8.1 prior to finishing. The reel loaded with wire or cable shall be conditioned in a temperature chamber at -40 deg
17、ree F for 24 hours prior to the drop test. The drop test shall be conducted immediately as soon as the reel is removed from the temperature chamber. If all the specified drops cannot be completed within 10 minutes after removal, immediately return the reel to the -40 degree F temperature chamber for
18、 1 hour before proceeding to the next 10 minute test period during which the reel may be dropped. After each 10 minute test period, immediately return the reel to the cold temperature chamber before proceeding to the next 10 minute test period until all the specified drops have been completed. 4.8.1
19、 Each type of reel shall be loaded with a weight of wire or cable comparable to its normal use with total weight as follows: DR-5( ) 125 pounds DR-7( ) 133 pounds DR-8( ) 15 pounds RC-453( )/G 150 pounds RL-159( )/U 50 pounds 4.8.2 The reel shall be lifted off the floor by use of a hoist, equipped w
20、ith a quick release device. When the bottom of the reel is 3-1/2 feet above the 2 inch fir platform backed by a concrete floor, It shall be released so as to drop squarely on the perifery of both heads. 4.8.3 The reel shall then be lifted as above, held until motionless, and dropped squarely on one
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL3241F2010REELSCABLEREELSDR5DR7DRBRC453GRL159UPDF

链接地址:http://www.mydoc123.com/p-690583.html