DLA MIL-DTL-27190 C-2006 INDICATOR PRESSURE AGU-3 A HYDRAULIC 0-4 000 PSI《0-4 000 PSI液压力AGU-3 A指示器》.pdf
《DLA MIL-DTL-27190 C-2006 INDICATOR PRESSURE AGU-3 A HYDRAULIC 0-4 000 PSI《0-4 000 PSI液压力AGU-3 A指示器》.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-27190 C-2006 INDICATOR PRESSURE AGU-3 A HYDRAULIC 0-4 000 PSI《0-4 000 PSI液压力AGU-3 A指示器》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to Defense Supply Center Richmond, ATTN: DSCR-VEB, 8000 Jefferson Davis Highway, Richmond, VA 23297-5616 or e-mailed to STDZNMGTdla.mil. Since contact information can change, you may want to verify the currency of this address
2、information using the ASSIST database at http:/assist.daps.dla.mil. AMSC N/A FSC 6685 INCH-POUND MIL-DTL-27190C 19 December 2006 SUPERSEDING MIL-I-27190B 31 October 1967 DETAIL SPECIFICATION INDICATOR, PRESSURE AGU-3/A, HYDRAULIC, 0-4,000 PSI Inactive for new design after 24 March 1999. This specifi
3、cation is approved for use by all departments and agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one type of hermetically sealed, remote-indicating, synchro-type, integrally lighted, 0-4,000 pounds per square inch (psi) hydraulic pressure indicator, designated A
4、GU-3/A. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effor
5、t has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of the documents cited in sections 3 and 4 of this specification, whether or not they are listed. Provided by IHSNot for ResaleNo reproduction or networking permitted
6、without license from IHS-,-,-MIL-DTL-27190C 2 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are th
7、ose cited in the solicitation or contract (see 6.2). FEDERAL STANDARDS FED-STD-595 - Colors Used in Government Procurement (Color chips 37038 and 37875). DEPARTMENT OF DEFENSE SPECIFICATIONS MS3134 - Connector, Receptacle, Electric, Solder Type, Jam Nut Mounting, Push-Pull Coupling, Series 1 (Class
8、E, P, J and H). MS3137 - Connector, Plug, Electric, Solder Type, Push-Pull Coupling Series I (Class E, P and J). MIL-DTL-5541 - Chemical Conversion Coatings on Aluminum and Aluminum Alloys. MIL-S-7742 - Screw Threads, Standard, Optimum Selected Series: General Specification for. MIL-A-8625 - Anodic
9、Coatings for Aluminum and Aluminum Alloys. MIL-T-25307 - Transmitter, Pressure, Hydraulic, Type MJ-1. MIL-L-27160 - Lighting, Instrument, Integral, White General Specification for. MS33639 - Cases, Instrument, Clamp-Mounted, Aircraft. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-130 - Identification Mark
10、ing of U.S. Military Property. MIL-STD-461 - Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment. MIL-STD-810 - Environmental Engineering Considerations and Laboratory Tests. MIL-STD-889 - Dissimilar Metals. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDB
11、K-781 - Reliability Test Methods, Plans, and Environments for Engineering, Development, Qualification and Production. MIL-HDBK-831 - Preparation of Test Reports. (Copies of these documents are available at http:/assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue,
12、 Building 4D, Philadelphia, PA 19111-5094.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-27190C 3 2.2.2 Other government documents, drawings, and publications. The following other government documents, drawings, and publications form a par
13、t of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). STANDARDIZATION DOCUMENTS SD-6 - Provisions Governing Qualification. (Copies of these documents are available at http:/assist.daps.d
14、la.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are t
15、hose cited in the solicitation or contract (see 6.2). ASME INTERNATIONAL ASME Y14.100 - Engineering Drawing Practices. (Copies of these documents are available at http:/www.asme.org/ or from ASME International, Three Park Avenue, New York, NY 10016-5990.) SAE INTERNATIONAL SAE AS20708 - Synchros, Ge
16、neral Specification for. (Copies of these documents are available at http:/www.sae.org/ or from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001.) 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of th
17、is document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Qualification. Hydraulic pressure indicators furnished under this specification shall be products that are authorized by the
18、qualifying activity for listing on the applicable qualified products list before contract award (see 4.3 and 6.3). 3.2 Materials. 3.2.1 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent poss
19、ible provided that the material meets or exceeds the operational and maintenance requirements and promotes economically advantageous life cycle costs. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-27190C 4 3.2.2 Non-magnetic materials. Non-
20、magnetic materials shall be used for all parts of the indicator, except where magnetic materials are essential. 3.2.3 Non-ferrous materials. Non-ferrous materials shall be used for all parts of the indicator, except where ferrous materials are essential. 3.2.4 Metals. Metals shall be corrosion-resis
21、tant or suitably treated to resist corrosion due to fuels, salt spray, or atmospheric conditions likely to be met in storage or normal service. 3.2.5 Dissimilar metals. Unless suitably protected against electrolytic corrosion, dissimilar metals shall not be used in intimate contact with each other.
22、Dissimilar metals are defined in MIL-STD-889. 3.2.6 Toxic and corrosive fumes. The indicator shall be of such material and construction that when burned, fumes or gases that combine with the atmosphere to form acid or corrosive alkali will not be released. 3.2.7 Protective treatment. When materials
23、are used in the construction of the indicator that are subject to deterioration when exposed to climatic and environmental conditions likely to occur during service usage, they shall be protected against such deterioration in a manner that will in no way prevent compliance with the requirements of t
24、his specification. The use of any protective coating that will crack, chip, or scale with age or extremes of climatic and environmental conditions shall be avoided. 3.3 Design and construction. The indicator shall be designed for use with the type MJ-1 transformer conforming to MIL-T-25307. 3.3.1 Ca
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL27190C2006INDICATORPRESSUREAGU3AHYDRAULIC04000PSI04000PSI 液压 AGU3A 指示器 PDF

链接地址:http://www.mydoc123.com/p-690296.html