DLA DSCC-DWG-04044 REV C-2010 WIRE ELECTRICAL COMPOSITE POLYTETRAFLUOROETHYLENE POLYIMIDE INSULATED NORMAL WEIGHT NICKEL COATED HIGH STRENGTH OR ULTRA HIGH STRENGTH COPPER ALLOY 26.pdf
《DLA DSCC-DWG-04044 REV C-2010 WIRE ELECTRICAL COMPOSITE POLYTETRAFLUOROETHYLENE POLYIMIDE INSULATED NORMAL WEIGHT NICKEL COATED HIGH STRENGTH OR ULTRA HIGH STRENGTH COPPER ALLOY 26.pdf》由会员分享,可在线阅读,更多相关《DLA DSCC-DWG-04044 REV C-2010 WIRE ELECTRICAL COMPOSITE POLYTETRAFLUOROETHYLENE POLYIMIDE INSULATED NORMAL WEIGHT NICKEL COATED HIGH STRENGTH OR ULTRA HIGH STRENGTH COPPER ALLOY 26.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、REVISIONS LTR DESCRIPTION DATE APPROVED A Modifications to agree with SAE AS22759/90. Editorial changes throughout. 06/30/07 Lee Suroweic B Added approved supplier. Editorial changes throughout. 1 March 2009 Abdo Abdouni C Added approved supplier. 8 September 2010 Abdo Abdouni Prepared in accordance
2、 with ASME Y14.100 Selected item drawing REV PAGE REV STATUS OF PAGES REV C B B B B B B B C PAGE 1 2 3 4 5 6 7 8 9 PMIC PREPARED BY DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OHIO 43218-3990 William Carpenter Original date of drawing 12 July 2004 CHECKED BY TITLE Lee Surowiec WIRE, ELECTRICAL, COMPOS
3、ITE, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, NORMAL WEIGHT, NICKEL COATED, HIGH STRENGTH OR ULTRA HIGH STRENGTH COPPER ALLOY, 260C, 600 VOLT APPROVED BY Richard L. Taylor SIZE CAGE CODE DWG. NO. 04044 A 037Z3 REV C PAGE 1 OF 9 AMSC N/A 6145-E097-008 CURRENT DESIGN ACTIVITY CAGE CODE 037Z3 HAS C
4、HANGED NAMES TO: DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 04044 REV B PAGE 2 FP Fluorocarbon Polymer, modifi
5、ed Polytetrafluoroethylene (PTFE) FIGURE 1. General configuration. 1 SCOPE 1.1 Scope. This drawing covers the performance characteristics for a composite wire using a seamless polytetrafluoroethylene/ hydrolysis resistant polyimide tape wrap insulation system, with a light weight stranded conductor.
6、 1.2 Part or Identifying Number (PIN). The complete PIN should be as specified on the requirements drawing and constructed using the following format: 04044 - 20 - 9 1.2.1 Alloy conductor. The size 26 conductor should be ultra high strength copper alloy. The breaking strength should be 21.5 lbs. (mi
7、n.) and the conductor elongation 6.0% (min.). All other gauge sizes should be high strength copper alloy in accordance with SAE AS22759. Wire size (see table I) DSCC drawing number Insulation color designator (see table I) CONDUCTOR, STRANDED, SMALL DIAMETER, NICKEL COATED, HIGH STRENGTH OR ULTRA HI
8、GH STRENGTH COPPER ALLOY FP / POLYIMIDE / FP TAPE FP TAPE Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 04044 REV B PAGE 3 TABLE I. Details of construction AWG c
9、onductors. PIN Wire size (AWG) Conductor Finished wire Stranding (number of strands X gauge (AWG) of strands) Diameter (in.) Resistance at 20C ohms/1000ft (max) Diameter (in.) Weight lb/1000ft. (max) Min Max Min Max 04044-26-* 26 19 X 38 .0175 .0204 58.4 .033 .037 1.55 04044-24-* 24 19 X 36 .0225 .0
10、254 30.1 .038 .042 2.15 04044-22-* 22 19 X 34 .0285 .0314 18.6 .043 .047 3.00 04044-20-* 20 19 X 32 .0365 .0404 11.4 .051 .055 4.55 * The asterisks in the PIN column of table I should be replaced by color code designators (see 1.2.2). Example: 04044-26-93 is white with an orange stripe. 1.2.2 Color.
11、 The wire insulation color should be indicated by the color designator (see 1.2) and as specified in the contract. The insulation color should be in accordance with MIL-STD-681, system 1, differentiation color coding chassis wiring (3 numbers maximum). For laser marked wires, color limits should be
12、in accordance with MIL-STD-104, class I, or in accordance with table V of this drawing. 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein
13、. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-104 - Limits for Electrical Insulation Color MIL-STD-681 - Identification Coding and Application of Hookup and Lead Wire MIL-STD-2223 - Test Methods fo
14、r Insulated Electric Wire (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Non-Government publications. The following documents form a part of this
15、document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. ASTM INTERNATIONAL ASTM B355 - Standard Specification for Nickel Coated Soft or Annealed Copper Wire ASTM B624 - Standard Specification for High Strengt
16、h, High Conductivity Copper Alloy Wire for Electronic Application ASTM D3032 - Standard Test Methods for Hookup Wire Insulation ASTM D4591 - Standard Test Method for Determining Temperatures and Heats of Transitions of Fluoropolymers by Differential Scanning Calorimetry (Copies of these documents ar
17、e available from http:/www.astm.org/ or ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, Pennsylvania, USA 19428-2959.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990
18、SIZE CAGE CODE DWG NO. A 037Z3 04044 REV B PAGE 4 NCSL INTERNATIONAL NCSL Z540.3 - General Requirements for Calibration of Measuring and Test Equipment (Copies of these documents are available from http:/www.ncsli.org or to National Conference of Standards Laboratories (NCSL), 2995 Wilderness Place,
19、 Suite 107, Boulder, CO 80301-5404.) SAE INTERNATIONAL SAE-AS4373 - Test Methods for Insulated Electric Wire SAE-AS22759 - Wire, Electrical, Fluoropolymer-Insulated, Copper or Copper Alloy SAE-AS22759/90 - Wire, Electrical, Polytetrafluoroethylene/polyimide Insulated, Normal Weight, Nickel Coated, H
20、igh Strength or Ultra High Strength Copper Alloy, 260C, 600 Volts (Copies of these documents are available from http:/www.sae.org/ or SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001). 3. REQUIREMENTS 3.1 DSCC requirements. Items described in this drawing shall meet the requireme
21、nts of SAE-AS22759 and SAE AS22759/90 except as specified herein. Any requirements included in this drawing shall be in addition to, or supersede those requirements included in SAE-AS22759 and SAE-AS22759/90. In case of conflict between the requirements in this drawing, SAE-AS22759, and SAE-AS22759/
22、90, the requirements of this drawing shall take precedence. 3.2 Design configuration. The design, construction, and physical dimensions shall be as specified in this drawing. 3.2.1 Design documentation. Design documentation shall be retained by the manufacturer and shall be available upon request fo
23、r review by the contracting activity, DSCC, or contractor. 3.3 Material. 3.3.1 Conductor. Conductors shall be made of high strength or ultra high strength copper-alloy in accordance with ASTM B624, paragraph 1.2.1, and table I of this drawing. All strands shall be free from lumps, kinks, splits, sca
24、rred or corroded surfaces and skin impurities. Strands shall be nickel coated. The nickel coating shall not be less than 50 microinches (1.27 m) when tested in accordance with ASTM B355. 3.3.2 Insulation. Insulation shall be polytetrafluoroethylene and polytetrafluoroethylene/polyimide tape in accor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLADSCCDWG04044REVC2010WIREELECTRICALCOMPOSITEPOLYTETRAFLUOROETHYLENEPOLYIMIDEINSULATEDNORMALWEIGHTNICKELCOATEDHIGHSTRENGTHORULTRAHIGHSTRENGTHCOPPERALLOY26PDF

链接地址:http://www.mydoc123.com/p-688590.html