1、Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to: STDZNMGTdla.mil or Defense Logistics Agency Aviation VEB, 8000 Jefferson Davis Highway, Richmond, VA 23297-5616. Since contact information can change, you m
2、ay want to verify the currency of this address information using the ASSIST database at https:/assist.daps.dla.mil/. AMSC N/A FSC 6830 INCH-POUND BB-H-1168D 15 November 2010 SUPERSEDING BB-H-1168C 3 August 2000 FEDERAL SPECIFICATION HELIUM, TECHNICAL The General Services Administration has authorize
3、d the use of this federal specification by all federal agencies. 1. SCOPE AND CLASSIFICATION 1.1 Scope. This specification covers two technical grades of gaseous helium (see 6.1). 1.2 Classification. The helium shall be of the following grades, as specified (see 6.2): Grade A - 99.995 percent helium
4、 Grade B - 97.5 percent helium 2. APPLICABLE DOCUMENTS 2.1 Government publications. The issues of the following documents, in effect on the date of invitation for bids or request for proposal, form a part of this specification to the extent specified herein. Federal Specification RR-C-901 - Cylinder
5、s, Compressed Gas: Seamless Shatterproof, High Pressure DOT 3AA Steel, and 3AL Aluminum Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BB-H-1168D 2 Federal Standard FED-STD-123 - Marking for Shipment (Civil Agencies) Commercial Item Description A-A-
6、59860 - Valves, Cylinder, Gas (for Compressed or Liquefied Gases) (Activities outside the federal government may obtain copies of federal specifications, standards, and commercial item descriptions as specified in the General Information section of the Index of Federal Specifications, Standards and
7、Commercial Item Descriptions. The index is for sale on a subscription basis from the General Services Administration, Federal Supply Service, Specification Section, East 470 LEnfant Plaza SW, Suite 8100, Washington, DC 20407.) (Single copies of this specification, and other federal specifications, s
8、tandards and commercial item descriptions required by activities outside the federal government for bidding purposes are available without charge from the General Services Administration, Federal Supply Service, Specification Section, East 470 LEnfant Plaza SW, Suite 8100, Washington, DC 20407.) (Fe
9、deral government activities may obtain copies of federal standardization documents and the Index of Federal Specifications, Standards and Commercial Item Descriptions from established distribution points in their agencies. Electronic copies may be obtained from https:/assist.daps.dla.mil/.) Military
10、 Standards MIL-STD-101 - Color Code for Pipelines and for Compressed Gas Cylinders MIL-STD-129 - Military Marking for Shipment and Storage MIL-STD-1411 - Inspection and Maintenance of Compressed Gas Cylinders (Copies of military standards required by contractors in connection with specific procureme
11、nt functions are available from the Standardization Document Order Desk, Building 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094. Electronic copies may be obtained from https:/assist.daps.dla.mil/.) Federal Regulations 43 CFR 3195 - Helium Contracts 49 CFR 171-181 - Hazardous Materials Regulati
12、ons Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BB-H-1168D 3 (The Code of Federal Regulations (CFR) is for sale on a subscription basis from the Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954. When indicated, reprints of
13、certain regulations may be obtained from the federal agency responsible for issuing them. Electronic copies may be obtained from http:/www.gpoaccess.gov/ecfr/.) 2.2 Other publications. The following documents form a part of this specification to the extent specified herein. Unless a specific issue i
14、s identified, the issue in effect on the date of invitation for bids or request for proposal shall apply. Bureau of Land Management (BLM) Information Circular (IC) 8367 - Computing Volume of Helium in Cylindrical Steel Containers at 10 to 10,000 psia Report of Investigations (RI) 7444 - An Improved
15、Method and Apparatus for Analysis of Impurities in Helium (The above circular and report were drafted by the Bureau of Mines (USBM), which has been absorbed by the BLM. Application for copies should be addressed to the Bureau of Land Management, Helium Operations Office, 801 South Fillmore Street, S
16、uite 500, Amarillo, TX 79101-3545.) Compressed Gas Association (CGA) CGA P-15 - Filling of Industrial and Medical Nonflammable Compressed Gas Cylinders (Application for copies should be addressed to the Compressed Gas Association, 4221 Walney Road, 5th Floor, Chantilly, VA 20151-2923. Electronic cop
17、ies may be obtained from http:/ 3. REQUIREMENTS 3.1 Material. Helium shall be Bureau of Land Management helium pursuant to 43 CFR 3195 (see 6.3). 3.2 Pressure. Each container shall be filled to the maximum pressure authorized by 49 CFR 171-181, when tested as specified in 4.5.1. The net content of h
18、elium shall be corrected to 70 F and 14.7 pounds per square inch absolute (psia) and reported in standard cubic feet as shown in IC 8367. 3.3 Leakage. Each container shall show no evidence of leakage when tested as specified in 4.5.2. 3.4 Helium (grade A). Grade A helium shall contain not greater th
19、en 50 parts per million (ppm) by volume aggregate impurities, when tested as specified in 4.5.3. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BB-H-1168D 4 3.5 Helium (grade B). Grade B helium shall exhibit non-flammability and buoyancy, when teste
20、d as specified in 4.5.4. 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the contractor is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contrac
21、t or order, the contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the government. The government reserves the right to perform any of the inspections set forth in the specification where such inspect
22、ions are deemed necessary to assure that supplies and services conform to prescribed requirements. 4.2 Points of inspection. When helium containers are filled from production plant systems or other storage facilities for delivery to destination by any mode of transportation, quality conformance insp
23、ection shall be conducted on the containers and their contents prior to leaving the site of filling or shipment. 4.3 Examination of preparation for delivery. The packing and marking of the cylinders shall be examined to determine compliance with the requirements of section 5. 4.3.1 Individual tests.
24、 Each container shall be tested for filling pressure and leakage as specified in 4.5.1 and 4.5.2. 4.3.2 Sampling tests. When applicable, helium shall be sampled and tested, as specified in 4.5.3 or 4.5.4. 4.3.2.1 Lots. When helium cylinders are filled, each group of cylinders charged on the same man
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLABBH1168D2010HELIUMTECHNICALPDF