DLA A-A-59215 C-2012 LEADS STORAGE-BATTERY.pdf
《DLA A-A-59215 C-2012 LEADS STORAGE-BATTERY.pdf》由会员分享,可在线阅读,更多相关《DLA A-A-59215 C-2012 LEADS STORAGE-BATTERY.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to DLA Aviation, VEB, 8000 Jefferson Davis Highway, Richmond, VA 23297-5616 or e-mailed to STDZNMGTdla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST
2、database at https:/assist.dla.mil FSC 6150 INCH-POUND A-A-59215C 11 September 2012 SUPERSEDING A-A-59215B 01 May 2007 COMMERCIAL ITEM DESCRIPTION LEADS, STORAGE-BATTERY The General Services Administration has authorized the use of this commercial item description for all federal agencies. 1. SCOPE.
3、This commercial item description (CID) covers low tension cables used for connections between storage batteries and other electrical equipment. The insulated leads are used for connections between the battery and equipment where heavy amperage 6-, 12-, and 24-volt (V) ungrounded circuits interconnec
4、t. The uninsulated leads and straps are used for bonding and grounding connections. 2. CLASSIFICATION. The leads shall be of the following types, classes, and styles as specified (see 7.3(b). Type I - Ground lead, uninsulated strap, flat woven or braided Style 1 - Battery to ground Style 2 - Ground
5、to ground (bonding strap) Type II - Battery lead, insulated (rope strand, concentric lay, or bunched) Class A - Extra-flexible rope strand Class B - Stranded concentric lay or bunched Style 1 - Rope lay, concentric lay, or bunched with generator lead Style 2 - Rope lay, concentric lay, or bunched wi
6、th lugs Style 3 - Rope lay, concentric lay, or bunched with straight universal post terminals Style 4 - Rope lay, concentric lay, or bunched with angle universal post terminals Style 5 - Rope lay, concentric lay, or bunched with side terminal and lug Style 6 - Rope lay, concentric lay, or bunched wi
7、th side terminals Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59215C 2 3. SALIENT CHARACTERISTICS 3.1 Standard commercial product. The storage battery leads shall, as a minimum, be in accordance with the requirements of this CID and shall be
8、the manufacturers standard commercial product. Additional or better features which are not specifically prohibited by this CID but which are a part of the manufacturers standard commercial product shall be included in the storage battery leads being furnished. 3.2 Materials. The storage battery lead
9、s shall consist of a specified length (see 7.3(c) of low tension cable defined as a center to center distance between terminal holes (cable length) which is terminated at each end with a post terminal lug as specified. 3.3 Design. Insulator boots or caps shall be provided for type I, style 1 leads a
10、nd provide an additional margin of safety during installation and servicing of the battery cable connections. Type II, class A or B leads, styles 1 through 6 shall be provided with insulator boots or caps to prevent inadvertent contact with energized conductors. Material used for construction of the
11、 cable or lead insulation shall be consistent with standard commercial practice. 3.3.1 Type I. Type I ground leads are uninsulated flat strips and shall be composed of braided copper conductors and plated to resist corrosion. 3.3.1.1 Type I, style 1. Type I, style 1 ground leads shall be plated to r
12、esist corrosion and shall have a post terminal (see 3.3.5.1) on one end and a terminal lug (see 3.3.5.3) on the other end. The style 1 lead is used for connection from the battery to ground. 3.3.1.2 Type I, style 2. Type I, style 2 ground leads shall be uncoated and have a terminal lug (see 3.3.5.3)
13、 on each end for use from engine to ground. 3.3.2 Type II. Type II insulated leads shall be general purpose, insulated, braidless, and classified as extra flexible rope strand construction (class A), bunched, or stranded concentric lay (class B). 3.3.2.1 Type II, class A. Type II, class A insulated
14、extra flexible rope strand leads are used for connection between the battery and the starter, the battery and the solenoid, the starter and the solenoid, or the battery and the ground. 3.3.2.2 Type II, class B. Type II, class B insulated strand concentric lay or bunched leads are used for connection
15、 between the battery and the starter, the battery and the solenoid, the starter and the solenoid, or the battery and the ground. 3.3.3 Cable style. Type II, class A or B cable designs shall be designated by the cable styles. 3.3.3.1 Type II, class A or B, style 1. Type II, class A or B, style 1 lead
16、s shall be an insulated generator lead attached to a universal post terminal (see 3.3.5.1). The other end of the lead shall be fitted with a terminal lug (see 3.3.5.3). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59215C 3 3.3.3.2 Type II, cla
17、ss A or B, style 2. Type II, class A or B, style 2 leads shall have a terminal lug (see 3.3.5.3) on each end. This style lead is used for connection between the solenoid and starter and similar applications. 3.3.3.3 Type II, class A or B, style 3. Type II, class A or B, style 3 leads shall have stra
18、ight-neck post terminals (see 3.3.5.1) on each end. The post terminals used shall be the universal type fitting either a negative or positive battery post. This style lead is used as a connector when arranging batteries in series or parallel combinations. 3.3.3.4 Type II, class A or B, style 4. Type
19、 II, class A or B, style 4 leads shall have angle type post terminals (see 3.3.5.1). The post terminals used on these leads shall be the universal type arranged 180 degrees with respect to each other. This style lead is used as a connector when arranging batteries in series or parallel combinations.
20、 3.3.3.5 Type II, class A or B, style 5. Type II, class A or B, style 5 leads shall have a side terminal with an integral bolt (see 3.3.5.2) on one end and a lug (see 3.3.5.3) on the other end. This style lead is used for connection between a side terminal battery and the starter or between the batt
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA59215C2012LEADSSTORAGEBATTERYPDF