DLA A-A-50688-1990 SENTRY BUILDING MOBILE《移动岗亭》.pdf
《DLA A-A-50688-1990 SENTRY BUILDING MOBILE《移动岗亭》.pdf》由会员分享,可在线阅读,更多相关《DLA A-A-50688-1990 SENTRY BUILDING MOBILE《移动岗亭》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、E Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data which may improve this document should be sent to: Defense Construction Supply Center P.O. Box 3990, ATTN: DCSC-SSM, Columbus, Ohio I 43216-5000. 21 Mar 90 COMMERCIAL ITEM DESCRIPTION SENTRY BUILDING, MO
2、BILE The General Services Administration has authorized the u8e of this comercial item description. Abstract. This commercial item description delineates a mobile sent;ry building used as a sentry shelter and as a portable re- viewing 8tand. Salient Characterl8tics. Sentry building shall be a traile
3、r mounted unit, constructed to conform to Department of Transportation (DOT) Fedenal Motor Carrier Safety Regulation= and Vehicle Safety Standards. Building shall be constructed to have a 6.0 Ft. minimum external width, 5.0 Ft. minimurn external length, and a 6.5 Ft. minimum internal height. Buildin
4、g to include an external platform, 6.0 Ft. nominal width by 3.0 Ft. nominal length. Building and plat- form shall be mounted on a welded steel frame, 8.0 Ft. minimum external width by 8.0 Ft. minimum external length. Frame shall be equipped with a single axle, pneumatic tires, 2 inch ball hitch with
5、 safety chain=, 4 corner Jacks for leveling, swing down step, hand rails, and running lights. Building shall be of metal construction with all interior sur- face8 to be insulated to a minimum rating of R11 and canopy to extend no less than 3 inches beyond walls. Entrance shall be a fully weather str
6、ipped door with a 18 by 16 inch minimum glass window in the door. All windows shall be clear tempered safety glass 118 inch minimum thickness. Window6 shall be installed in 3 or 4 wall8 with a minimum of 4,863 square inches of window area. Windows on opposing sides shall be sliding type equipped wit
7、h screens. Lacks and hardware shall be installed. AMSC N/A FSC 5410 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. y* Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Complete unit shall be wired in accordance with t
8、he National Electric Code and contain a 100 AMP 12 circuit breaker box, duplex outlet and fluorescent light fixture. Heating and cooling shall be provided by a llOV/12OV, 5,000 BTU minimum heater and a llOV/lSOV, 6,000 BTU minimum cooler. Heater/Cooler combination unit is acceptable. Interior shall
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA506881990SENTRYBUILDINGMOBILE 移动 岗亭 PDF