DIN EN ISO 14189-2016 Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration (ISO 14189 2013) German version EN ISO 14189 2016《水质 产气荚膜梭菌的枚举 使用膜过滤.pdf
《DIN EN ISO 14189-2016 Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration (ISO 14189 2013) German version EN ISO 14189 2016《水质 产气荚膜梭菌的枚举 使用膜过滤.pdf》由会员分享,可在线阅读,更多相关《DIN EN ISO 14189-2016 Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration (ISO 14189 2013) German version EN ISO 14189 2016《水质 产气荚膜梭菌的枚举 使用膜过滤.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、November 2016 English price group 12No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 07.100.20!%v#“2588300www.din.de
2、DIN EN ISO 14189Water quality Enumeration of Clostridium perfringens Method using membrane filtration (ISO 14189:2013);English version EN ISO 14189:2016,English translation of DIN EN ISO 14189:2016-11Wasserbeschaffenheit Zhlung von Clostridium perfringens Verfahren mittels Membranfiltration (ISO 141
3、89:2013);Englische Fassung EN ISO 14189:2016,Englische bersetzung von DIN EN ISO 14189:2016-11Qualit de leau Dnombrement de Clostridium perfringens Mthode de filtration sur membrane (ISO 14189:2013);Version anglaise EN ISO 14189:2016,Traduction anglaise de DIN EN ISO 14189:2016-11www.beuth.deDocumen
4、t comprises 21 pagesDTranslation by DIN-Sprachendienst.In case of doubt, the German-language original shall be considered authoritative.11.16 DIN EN ISO 14189:2016-11 2 A comma is used as the decimal marker. National foreword The text of ISO 14189:2013 has been prepared by Technical Committee ISO/TC
5、 147 “Water quality” and has been taken over as EN ISO 14189:2016 by Technical Committee CEN/TC 230 “Water analysis” (Secretariat: DIN, Germany). The responsible German body involved in its preparation was DIN-Normenausschuss Wasserwesen (DIN Standards Committee Water Practice), Working Committee NA
6、 119-01-03-03 UA Mikrobiologie of NA 119-01-03 AA Wasseruntersuchung. Designation of the method: Enumeration of Clostridium perfringens Method using membrane filtration (K 24): Method DIN EN ISO 14189 K 24 For the national implementation of this standard in Germany, the following should be noted: Th
7、e 4thparagraph of normative Annex A.3 “Acid phosphatase reagent” deviates from the original literature 1 according to which the buffer solution should be made up as follows: “Prepare the acetate buffer by dissolving 0,3 ml glacial acetic acid (CAS-No.: 64-19-7) and 0,4 g sodium acetate (CAS No.: 127
8、-09-3) in deionized water and make up to 100 ml. Alternatively use a commercially available product.” The acid phosphatase reagent contains a toxic and carcinogenic substance (Fast Blue B Salt). It is complicated to prepare and has a short storage life. Therefore, on recommendation of Working Commit
9、tee NA 119-01-03-03 UA Mikrobiologie, an alternative detection procedure for acid phosphatase should be taken into account. This includes anaerobic subculturing of the colonies to be tested on m-CP-agar for (21 3) h at (36 2) C and subsequent steaming with ammonium hydroxide for 20 s to 30 s. If col
10、onies that were initially dark yellow turn rose to red, acid phosphatase shall be deemed to be verified. The DIN Standards corresponding to the International Standards referred to in this document are as follows: ISO 3696 DIN ISO 3696 ISO 5725-2 DIN ISO 5725-2 ISO 8199 DIN EN ISO 8199 ISO 19458 DIN
11、EN ISO 19458 ISO/TR 13843 DIN V ENV ISO 13843 ISO/TS 11133-1 DIN ISO/TS 11133-1 ISO/IEC Guide 2 DIN EN 45020 DIN EN ISO 14189:2016-11 3 Expert assistance and specialized laboratories will be required to perform the analyses described in this standard. Existing safety requirements are to be observed.
12、 Depending on the objective of the analysis, a check shall be made on a case-by-case basis as to whether and to what extent additional conditions will have to be specified. This standard has been prepared by DIN-Normenausschuss Wasserwesen (DIN Standards Committee Water Practice) in collaboration wi
13、th the Wasserchemische Gesellschaft - Fachgruppe in der Gesellschaft Deutscher Chemiker (Water Chemistry Society - Division of the German Chemical Society). It is part of the series Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlammuntersuchung (German standard methods for the examination
14、 of water, waste water and sludge): Enumeration of Clostridium perfringens Method using membrane filtration (K 24). Standard methods published as DIN Standards are obtainable from Beuth Verlag GmbH, either individually or grouped in volumes. The standard methods included in the loose-leaf publicatio
15、n entitled Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlammuntersuchung will continue to be published by Beuth Verlag GmbH and Wiley-VCH Verlag GmbH b) all details necessary for the complete identification of the sample;c) the number of colonies presumptive C. perfringens (optional, dep
16、ending on the purpose of the investigation);d) the number of colonies confirmed as C. perfringens;e) information, if the result represents the total number of C. perfringens (vegetative cells and spores) or spores only;f) any particular occurrence(s) observed during the analysis and any operation(s)
17、 not specified in this method, which may have affected the results.11 Quality assuranceThe laboratory shall have a clearly defined quality control system to ensure that the apparatus, reagents and techniques are suitable for the test. The use of positive controls, negative controls and blanks is par
18、t of the test.Media quality control is described in ISO/TS 11133-1. For quantitative process quality control a suspension of C. perfringens is used for this purpose. Select the volume filtered to contain between 10 cfu to 80 cfu and treat the control like a sample. Compare recovery to that on a non-
19、selective agar such as blood agar. Alternatively to the suspension of C. perfringens use reference materials.NOTE Since the medium should be used as fresh as possible it is acceptable to perform media and process control for samples simultaneously in parallel with the analysis of the samples.Include
20、 a blank control in each batch of analyses. Filter 100 ml of sterile water or another appropriate diluent according to ISO 8199 and continue to treat it like a sample but without pasteurization. No colonies should be visible after incubation.Include an appropriate control for correct anaerobic condi
21、tions (e.g. anaerobic indicator strip) whenever anaerobic incubation is performed (anaerobic jar or anaerobic incubator).For the confirmation step performed by acid phosphatase test include known positive and negative control strains.At least one of the C. perfringens strains given in Table 1 shall
22、be used as a positive control for media control and the confirmation test.10EN ISO 14189:2016 (E) DIN EN ISO 14189:2016-11 Bacillus subtilis WDCM 00003 shall be used as a negative control for assessing TSC medium and anaerobic conditions.Clostridium bifermentans WDCM 00079 shall be used as negative
23、control for the confirmation test.Table 1 Performance testing of Tryptose sulfite cycloserine agar (TSC agar) by comparing with a non-selective reference mediumFunction Incubation Control strainsaReference mediaMethod of controlCriteria Characteristic reac-tionsProductivity (21 3) h / (44 1) C anaer
24、obicClostridium perfrin-gens WDCM 00007; C. perfringens WDCM 00080; C. perfringens WDCM 00174TSA or blood agarQuantitative PR 0,5 Black coloniesSelectivity (21 3) h / (44 1) C anaerobicBacillus subtilis WDCM 00003 Qualitative Total inhibition (0)aRefer to the reference strain catalogue available on
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINENISO141892016WATERQUALITYENUMERATIONOFCLOSTRIDIUMPERFRINGENSMETHODUSINGMEMBRANEFILTRATIONISO141892013GERMANVERSIONENISO141892016

链接地址:http://www.mydoc123.com/p-679560.html