CSA T568 1-1-2005 Commercial building telecommunications cabling standard Part 1 General requirements Addendum 1 Minimum 4-pair UTP and 4-pair ScTP patch cable bend radius (Firs.pdf
《CSA T568 1-1-2005 Commercial building telecommunications cabling standard Part 1 General requirements Addendum 1 Minimum 4-pair UTP and 4-pair ScTP patch cable bend radius (Firs.pdf》由会员分享,可在线阅读,更多相关《CSA T568 1-1-2005 Commercial building telecommunications cabling standard Part 1 General requirements Addendum 1 Minimum 4-pair UTP and 4-pair ScTP patch cable bend radius (Firs.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、 T568.1-1-05(ANSI/TIA/EIA-568-B.1-1-2001)Commercial building telecommunications cabling standard Part 1: General requirements Addendum 1 Minimum 4-pair UTP and 4-pair ScTP patch cable bend radius CSA Standard T568.1-1-05 (ANSI/TIA/EIA-568-B.1-1-2001) Commercial building telecommunications cabling st
2、andard Part 1: General requirements Addendum 1 Minimum 4-pair UTP and 4-pair ScTP patch cable bend radiusPublished in May 2005 by Canadian Standards Association A not-for-profit private sector organization 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N61-800-463-6727 416-747-4044
3、Visit our Online Store at www.ShopCSA.ca Commercial building telecommunications cabling standard Part 1: General requirements Addendum 1 Minimum T568.1-1-05 4-pair UTP and 4-pair ScTP patch cable bend radius CSA/2 Canadian Standards Association May 2005 T568.1-1-05 Commercial building telecommunicat
4、ions cabling standard Part 1: General requirements Addendum 1 Minimum 4-pair UTP and 4-pair ScTP patch cable bend radius CSA Preface This is the first edition of CSA T568.1-1, Commercial building telecommunications cabling standard Part 1: General requirements Addendum 1 Minimum 4-pair UTP and 4-pai
5、r ScTP patch cable bend radius. This Standard is an adoption of the identically titled ANSI/TIA/EIA (American National Standards Institute/Telecommunications Industry Association/Electronic Industries Alliance) Standard 568-B.1-1-2001 and is the product of the Telecommunications Industry Association
6、 TR-42 Technical Committee, which included a number of Canadian members in order to ensure that Canadian perspectives and requirements were addressed. It is written in SI (metric) units with yard/pound (imperial) units in parentheses. This Standard has been adopted with no technical deviations. Wher
7、e code requirements or regulations necessitate changes from US to Canadian references, they should be made by the user, as follows: (a) Throughout this Standard, replace the term “American” with “Canadian”, as applicable. (b) Throughout this Standard, replace the term “state” with “provincial or ter
8、ritorial”, as applicable. (c) Throughout this Standard, replace “NEC” with “CE Code, Part I” (Canadian Electrical Code), as applicable. In addition, (i) where reference is made to “conduit”, replace it with “conduit/EMT” (electrical metallic tubing) because, in accordance with the Canadian Electrica
9、l Code, Part I, EMT is not considered a type of conduit; and (ii) the definitions of the following terms are to be taken from the Canadian Electrical Code, Part I: “Bonding”, “Ground”, and “Raceway”. (d) Throughout this Standard, where reference is made to “FCC”, replace it with “CRTC” (Canadian Rad
10、io-television and Telecommunications Commission), or “Industry Canada”, as applicable. (e) The following Standard, published by the Canadian Standards Association, is an adoption of a TIA/EIA Standard. The requirements of this CSA Standard take precedence over the TIA/EIA Standard on which it is bas
11、ed; any reference in CSA T568.1-1 to the TIA/EIA Standard is to be replaced by a reference to the equivalent Canadian Standard: T568.1-05, Commercial building telecommunications cabling standard Part 1: General requirements. (f) Throughout this Standard, replace the term “Listed” with “Approved as a
12、pplied to electrical equipment”. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Telecommunications Wiring Systems, under the jurisdiction of the Strategic Steering Committee on Information and Communications Technology, and has been formally approved by the Techni
13、cal Committee. A list of the members of the Technical Committee is available upon request. Commercial building telecommunications cabling standard Part 1: General requirements Addendum 1 Minimum T568.1-1-05 4-pair UTP and 4-pair ScTP patch cable bend radius May 2005 Canadian Standards Association CS
14、A/3 May 2005 Canadian Standards Association 2005 All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher. TIA/EIA material is reprinted with permission. Inquiries regarding this CSA Standard should be addressed to Canadi
15、an Standards Association 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6 1-800-463-6727 416-747-4044 www.csa.ca ANSI/TIA/EIA-568-B.1-1-2001 Approved: July 31, 2001 TIA/EIA STANDARD Cm TIA/EIA-568-B.1-1 Commercial Building Telecommunications Cabling Standard Part 1: General Require
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAT568112005COMMERCIALBUILDINGTELECOMMUNICATIONSCABLINGSTANDARDPART1GENERALREQUIREMENTSADDENDUM1MINIMUM4PAIRUTPAND4PAIRSCTPPATCHCABLEBENDRADIUSFIRSPDF

链接地址:http://www.mydoc123.com/p-621633.html