《CSA PLUS A440H-2014 User guide to AAMA WDMA CSA 101 I S 2 A440 NAFS 2011 - North Fenestration Standard Specification for windows doors and skylights (First Edition).pdf》由会员分享,可在线阅读,更多相关《CSA PLUS A440H-2014 User guide to AAMA WDMA CSA 101 I S 2 A440 NAFS 2011 - North Fenestration Standard Specification for windows doors and skylights (First Edition).pdf(102页珍藏版)》请在麦多课文档分享上搜索。
1、Plus A440H-14User guide to AAMA/WDMA/ CSA 101/I.S.2/A440 NAFS 2011 North Fenestration Standard/ Specification for windows, doors, and skylightsTMA trade-mark of the Canadian Standards Association, operating as “CSA Group”Plus A440H-14User guide to AAMA/WDMA/ CSA 101/I.S.2/A440 NAFS 2011 North Fenest
2、ration Standard/Specification for windows, doors, and skylightsPublished in April 2014 by CSA GroupA not-for-profit private sector organization5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N61-800-463-6727 416-747-4044Visit our Online Store at shop.csa.caISBN 978-1-77139-606-6 2014
3、 CSA GroupAll rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher.To purchase standards and related publications, visit our Online Store at shop.csa.ca or call toll-free 1-800-463-6727 or 416-747-4044.April 2014 iiiConte
4、nts American Architectural Manufacturers Association Window (b) provide an explanation of circumstances surrounding the actual field condition; and American Architectural Manufacturers Association Window (b) water penetration resistance;(c) air leakage;(d) operating force (where appropriate); and(e)
5、 forced-entry resistance (where appropriate).Clause 9 also includes optional test methods to evaluate acoustical performance, impact performance, condensation resistance, and thermal transmittance.Clause 10 presents the material requirements applicable to all windows, doors, SSPs, TDDs, roof windows
6、, and unit skylights. These include requirements for glazing, sash, panel, leaf, and frame materials.Clause 11 presents the component requirements applicable to all windows, doors, SSPs, TDDs, roof windows, and unit skylights. These include requirements for hardware, fasteners, weatherstripping, ins
7、ect screens, reinforcing members, sealants, coatings and finishes, adhesives, integral ventilating systems/devices, between-glass shades, setting blocks, attachments, and preservatives.Clause 12 presents the specific product performance requirements appropriate to each type of window, door, SSP, TDD
8、, roof window, and unit skylight. These include requirements for test specimens, such as product tolerance and qualifying the test specimen for variations of design and assembly.Table 12.2 contains a summary of all performance requirements included in NAFS. These requirements are presented in tabula
9、r format for easy use by the specifier and include references to the applicable clauses of NAFS, organized by product type.Annex A provides contact information for the standards development organizations listed in NAFS Clause 2.0.2 Performance Classes and Grades0.2.1 GeneralNAFS defines requirements
10、 for four Performance Classes. The Performance Classes are designated R, LC, CW, and AW for windows, doors, and secondary storm products (SSPs). Unit skylights, roof windows, and TDDs are not identified with a Performance Class, but are treated in a way similar to Specialty Products. This classifica
11、tion system provides for several levels of performance. It is important to note that although general suggestions for use are specified in Items (a) to (d), product selection is always based on the performance requirements of the particular project and not solely on these suggestions. The Performanc
12、e Class ratings should be regarded as an indication of the level of performance, with the least stringent requirements established for the R Performance Class and the most stringent for the AW Performance Class. The following descriptions can be used as a general guide in helping to determine which
13、class is likely best suited for a particular application:(a) R: commonly used in one- and two-family dwellings.(b) LC: commonly used in low-rise and mid-rise multi-family dwellings and other buildings where larger sizes and higher loading requirements are expected.(c) CW: commonly used in low-rise a
14、nd mid-rise buildings where larger sizes, higher loading requirements, limits on deflection, and heavy use are expected.(d) AW: commonly used in high-rise and mid-rise buildings to meet increased loading requirements and limits on deflection, and in buildings where frequent and extreme use of the fe
15、nestration products is expected.Minimum Performance Grades (PG), design pressures (DP), structural test pressures (STP), and water penetration resistance test pressures for all Performance Classes are specified in NAFS Table 12.2.Document reorganizedNAFS Table 0.1 lists those Clauses, Tables, and Fi
16、gures in the 2008 edition of NAFS that have been moved to a different location in the 2011 edition of NAFS. It does not list Clauses, Tables, and Figures that have been renumbered but not relocated.User guide to AAMA/WDMA/CSA101/I.S.2/A440NAFS 2011 North Fenestration Standard/Specification for windo
17、ws, doors, and skylightsApril 2014 3 American Architectural Manufacturers Association Window whereas some commercial building applications have been known to successfully use R and/or LC Performance Class fenestration products.0.2.3 Performance Grade (PG) designationsTo qualify for a given Performan
18、ce Grade (PG), one or more representative specimens of the product need to pass all required performance tests for the following, in addition to all required auxiliary (durability) tests for the applicable product type and desired Performance Class:(a) operating force (if applicable);(b) air leakage
19、 resistance;(c) water penetration resistance;(d) uniform load deflection test;(e) uniform load structural test; and(f) forced-entry resistance (if applicable).Performance Grades (PG) are designated by a number following the type and class designation. For example, a Class R window designated Class R
20、-PG15 indicates a Performance Grade (PG) of 15. This incorporates the design pressure (DP) of 720 Pa or approximately 15 psf.0.2.4 Positive and negative design pressure (DP)0.2.4.1The uniform load structural test pressure (STP) is:(a) 150% of the design pressure (DP) for windows and doors, and for u
21、plift on unit skylights, roof windows, and TDDs; and(b) 200% of the design pressure (DP) for download on unit skylights, roof windows, and TDDs.For Canada, design pressure (DP) for vertical fenestration is to be interpreted as referring to specified wind load.Table 0.1 (Concluded)2008 edition 2011 e
22、dition Topics CommentsClause 5.3.6.8Figure 23Clause 5.3.7Figure 5.1Unit dead load test (greenhouse windows only)Moved to applicable Product SectionClause 5.3.6.10Table 19Clause 6.4.7Table 6.8Operation/cycling-slam test performance (side-hinged door systems only)Moved to applicable Product SectionCla
23、use 5.3.6.11 Clause 6.4.8 Vertical loading resistance (side-hinged door systems only)Moved to applicable Product SectionClause 7.8 Clause 4.6 Mullions Moved to General Requirements for all product typesClause 7.12.1 Clause 12.3.4.1 True divided lites (TDLs) Moved to applicable Product SectionClause
24、9Table 26Clause 5.3.4Table 5.8Alternative minimum test sizes (and Performance Grades PG) for Class R products (optional)Applies only to Performance Class RUser guide to AAMA/WDMA/CSA101/I.S.2/A440NAFS 2011 North Fenestration Standard/Specification for windows, doors, and skylightsApril 2014 7 Americ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAPLUSA440H2014USERGUIDETOAAMAWDMACSA101IS2A440NAFS2011NORTHFENESTRATIONSTANDARDSPECIFICATIONFORWINDOWSDOORSANDSKYLIGHTSFIRSTEDITIONPDF

链接地址:http://www.mydoc123.com/p-621596.html