CSA N290 8-2015 Technical specification requirements for nuclear power plant components (First Edition).pdf
《CSA N290 8-2015 Technical specification requirements for nuclear power plant components (First Edition).pdf》由会员分享,可在线阅读,更多相关《CSA N290 8-2015 Technical specification requirements for nuclear power plant components (First Edition).pdf(53页珍藏版)》请在麦多课文档分享上搜索。
1、N290.8-15Technical specification requirements fornuclear power plant componentsLegal Notice for StandardsCanadian Standards Association (operating as “CSA Group”) develops standards through a consensus standards development process approvedby the Standards Council of Canada. This process brings toge
2、ther volunteers representing varied viewpoints and interests to achieve consensusand develop a standard. Although CSA Group administers the process and establishes rules to promote fairness in achieving consensus, it doesnot independently test, evaluate, or verify the content of standards.Disclaimer
3、 and exclusion of liabilityThis document is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation,implied warranties or conditions concerning this documents fitness for a particular purpose or use, its merchantability, or its n
4、on-infringementof any third partys intellectual property rights. CSA Group does not warrant the accuracy, completeness, or currency of any of the informationpublished in this document. CSA Group makes no representations or warranties regarding this documents compliance with any applicablestatute, ru
5、le, or regulation.IN NO EVENT SHALL CSA GROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS,OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED,INCLUDING BUT NOT LIMITED TO SPECIAL
6、 OR CONSEQUENTIAL DAMAGES, LOST REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGEDDATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS,WHETHER BASED IN CONTRACT,TORT (INCLUDING NEGLIGENCE), OR ANY OTHERTHEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN
7、 IF CSA GROUPHAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA Group is not undertaking to render professional or other services for or on behalf of anyperson or entity or to perform any duty owed by any person
8、 or entity to another person or entity. The information in this document is directedto those who have the appropriate degree of experience to use and apply its contents, and CSA Group accepts no responsibility whatsoeverarising in any way from any and all use of or reliance on the information contai
9、ned in this document.CSA Group is a private not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power, nor does itundertake, to enforce compliance with the contents of the standards or other documents it publishes.Intellectual property rights and ownersh
10、ipAs between CSA Group and the users of this document (whether it be in printed or electronic form), CSA Group is the owner, or the authorizedlicensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and allinventions and tr
11、ade secrets that may be contained in this document, whether or not such inventions and trade secrets are protected bypatents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document mayviolate laws that protect CSA Groups and/or ot
12、hers intellectual property and may give rise to a right in CSA Group and/or others to seek legalredress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA Group reserves all intellectualproperty rights in this document.Patent rightsAttention is draw
13、n to the possibility that some of the elements of this standard may be the subject of patent rights. CSA Group shall not beheld responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity ofany such patent rights is entir
14、ely their own responsibility.Authorized use of this documentThis document is being provided by CSA Group for informational and non-commercial use only. The user of this document is authorized to doonly the following:If this document is in electronic form: load this document onto a computer for the s
15、ole purpose of reviewing it; search and browse this document; and print this document if it is in PDF format.Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA Group to have suchcopies, and only if this Legal Notice appears on each suc
16、h copy.In addition, users may not and may not permit others to alter this document in any way or remove this Legal Notice from the attached standard; sell this document without authorization from CSA Group; or make an electronic copy of this document.If you do not agree with any of the terms and con
17、ditions contained in this Legal Notice, you may not load or use this document or make anycopies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of this documentconstitutes your acceptance of the terms and conditions of this Legal Notice.Stand
18、ards Update ServiceN290.8-15November 2015Title: Technical specification requirements for nuclear power plant componentsTo register for e-mail notification about any updates to this publication go to shop.csa.ca click on CSA Update ServiceThe List ID that you will need to register for updates to this
19、 publication is 2423732.If you require assistance, please e-mail techsupportcsagroup.org or call 416-747-2233.Visit CSA Groups policy on privacy at www.csagroup.org/legal to find out how we protect yourpersonal information.ISBN 978-1-77139-948-7 2015 CSA GroupAll rights reserved. No part of this pub
20、lication may be reproduced in any form whatsoeverwithout the prior permission of the publisher.Published in November 2015 by CSA GroupA not-for-profit private sector organization178 Rexdale Boulevard,Toronto, Ontario, Canada M9W 1R3To purchase standards and related publications, visit our Online Sto
21、re at shop.csa.caor call toll-free 1-800-463-6727 or 416-747-4044.TMA trade-mar k of the Canadian S tandards Association, operating as “CSA Group”Technical specificationrequirements for nuclear powerplant componentsN290.8-15N290.8-15Technical specification requirements for nuclear power plant compon
22、entsNovember 2015 2015 CSA Group 1ContentsTechnical Committee on Reactor Control Systems, Safety Systems, and Instrumentation for NuclearPower Plants 3Subcommittee on Technical Specification Requirements for Nuclear Power Plant Components 6Preface 81 Scope 102 Reference publications 113 Definitions
23、and abbreviations 153.1 Definitions 153.2 Abbreviations 184 Preparation of technical specifications 184.1 Procurement 184.2 Catalogue component 194.3 Referenced Codes, Standards, and generic specifications 194.4 Component standardization 204.5 Supplier capability 204.6 Units 204.7 Supplier submissio
24、ns 204.8 Design 214.9 Component interaction 224.10 Free issue material and services 224.11 Operating organization supplied design 224.12 QA requirements 234.13 Documentation requirements 234.13.1 List of engineering documents 234.13.2 Documentation, drawings, and bills of materials 234.13.3 Installa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAN29082015TECHNICALSPECIFICATIONREQUIREMENTSFORNUCLEARPOWERPLANTCOMPONENTSFIRSTEDITIONPDF

链接地址:http://www.mydoc123.com/p-621525.html