CEN TS 16450-2013 Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10 PM2 5)《环境空气 颗粒物浓度测量的自动测量系统(PM10 PM2 5)》.pdf
《CEN TS 16450-2013 Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10 PM2 5)《环境空气 颗粒物浓度测量的自动测量系统(PM10 PM2 5)》.pdf》由会员分享,可在线阅读,更多相关《CEN TS 16450-2013 Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10 PM2 5)《环境空气 颗粒物浓度测量的自动测量系统(PM10 PM2 5)》.pdf(50页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationPD CEN/TS 16450:2013Ambient air Automatedmeasuring systems forthe measurement of theconcentration of particulatematter (PM10; PM2,5)Copyright European Committee for Standardizati
2、on Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PD CEN/TS 16450:2013 PUBLISHED DOCUMENTNational forewordThis Published Document is the UK implementation ofCEN/TS 16450:2013.The UK participation in its preparation was entrust
3、ed to Technical Committee EH/2/3, Ambient atmospheres.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The Brit
4、ish Standards Institution 2013. Published by BSI Standards Limited 2013ISBN 978 0 580 78525 2 ICS 13.040.20 Compliance with a British Standard cannot confer immunity from legal obligations.This Published Document was published under the authority of the Standards Policy and Strategy Committee on 30
5、June 2013.Amendments issued since publicationDate T e x t a f f e c t e dCopyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PD CEN/TS 16450:2013TECHNICAL SPECIFICATION SPCIFICATION
6、TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 16450 May 2013 ICS 13.040.20 English Version Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5) Air ambiant - Systmes automatiss de mesurage de la concentration de matire particulaire (PM10
7、; PM2,5) Auenluft - Automatische Messeinrichtungen zur Bestimmung der Staubkonzentration (PM10; PM2,5) This Technical Specification (CEN/TS) was approved by CEN on 6 November 2012 for provisional application. The period of validity of this CEN/TS is limited initially to three years. After two years
8、the members of CEN will be requested to submit their comments, particularly on the question whether the CEN/TS can be converted into a European Standard. CEN members are required to announce the existence of this CEN/TS in the same way as for an EN and to make the CEN/TS available promptly at nation
9、al level in an appropriate form. It is permissible to keep conflicting national standards in force (in parallel to the CEN/TS) until the final decision about the possible conversion of the CEN/TS into an EN is reached. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croa
10、tia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and U
11、nited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. CEN/TS 16450
12、:2013: ECopyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PD CEN/TS 16450:2013CEN/TS 16450:2013 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 5 3 Terms and defini
13、tions .5 4 Symbols and abbreviated terms 9 5 Principle . 10 6 Sampling 11 7 Performance criteria and test procedures . 12 8 Field operation and ongoing quality control . 27 9 Data handling, validation and data reports 33 10 Expression of results . 34 11 Test reports and documentation . 35 Annex A (i
14、nformative) Examples of principles of AMS for monitoring of particulate matter . 36 Annex B (normative) Orthogonal regression algorithms . 39 Annex C (normative) Performing calibrations of the AMS . 41 Annex D (normative) Elements of type approval report . 42 Annex E (informative) Elements of suitab
15、ility evaluation report . 44 Annex F (informative) Relationship with EU Directives . 45 Bibliography . 46 Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PD CEN/TS 16450:2013CEN/
16、TS 16450:2013 (E) 3 Foreword This document (CEN/TS 16450:2013) has been prepared by Technical Committee CEN/TC 264 “Air quality”, the secretariat of which is held by DIN. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or
17、CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to announce this Technical Specification: Austria, Belgium, Bulgaria, Croatia, Cyprus, Cze
18、ch Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdo
19、m. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PD CEN/TS 16450:2013CEN/TS 16450:2013 (E) 4 1 Scope In order to be in compliance with EU Air Quality Directive requirements 1,
20、the reference methods given in the Directive for the measurement of mass concentrations of particulate matter are not commonly used for operation in routine monitoring networks. These networks usually apply automated continuous measurement systems (AMS), such as those based on the use of oscillating
21、 microbalances or -ray attenuation, and on in-situ optical methods. Such AMS are typically capable of producing 24-hour average measurement values over a measurement range up to 1 000 g/m3and 1-hour average measurement values up to 10 000 g/m3, if applicable, where the volume of air is the volume at
22、 ambient conditions near the inlet at the time of sampling. The 1-hour average values may be used for: direct information of the public; aggregation to produce daily or yearly average concentration values for regulatory reporting purposes. EU Air Quality Directive 2008/50/EC 1 allows the use of such
23、 systems after demonstration of equivalence with the reference method, i.e., after demonstration that these systems meet the Data Quality Objectives for continuous measurements. Guidelines for the demonstration of equivalence are given in Reference 2. This Technical Specification lays down the minim
24、um performance requirements and test procedures for the selection of appropriate AMS for particulate matter (type approval). This includes the evaluation of its equivalence with the reference method. Further, this Technical Specification describes minimum requirements for ongoing quality assurance q
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CENTS164502013AMBIENTAIRAUTOMATEDMEASURINGSYSTEMSFORTHEMEASUREMENTOFTHECONCENTRATIONOFPARTICULATEMATTERPM10PM25

链接地址:http://www.mydoc123.com/p-592646.html