CAN CSA-E60598-2-3 AMD 2-2002 Amendment 2 Luminaires – Part 2-3 Particular requirements – Luminaires for road and street lighting (First Edition).pdf
《CAN CSA-E60598-2-3 AMD 2-2002 Amendment 2 Luminaires – Part 2-3 Particular requirements – Luminaires for road and street lighting (First Edition).pdf》由会员分享,可在线阅读,更多相关《CAN CSA-E60598-2-3 AMD 2-2002 Amendment 2 Luminaires – Part 2-3 Particular requirements – Luminaires for road and street lighting (First Edition).pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Amendment 2:2002 to National Standard of CanadaCAN/CSA-E60598-2-3-98Amendment 2:2000 to International Standard CEI/IEC 598-2-3:1993 has beenadopted without modification (IDT) as Amendment 2:2002 to CAN/CSA-E60598-2-3-98. This Amendment was reviewed by the CSA Technical Committee onInternational Stan
2、dards under the jurisdiction of the Strategic Resource Group andhas been formally approved by the Technical Committee.February 2002Modification 2:2002 la Norme nationale du CanadaCAN/CSA-E60598-2-3-98LAmendement 2:2000 la norme internationale CEI/IEC 598-2-3:1993 a tadopt sans modification (IDT) et
3、constitue la Modification 2:2002 la normeCAN/CSA-E60598-2-3-98. Cette modification a t revue par le Comittechnique CSA sur les normes internationales sous lautorit du Groupe surles ressources stratgiques et a t approuve par le Comit technique.Fvrier 2002Amendement 2 Luminaires Partie 2-3: Rgles part
4、iculires Luminaires dclairage public Amendment 2 Luminaires Part 2-3: Particular requirements Luminaires for road and street lighting Commission Electrotechnique Internationale International Electrotechnical Commission Pour prix, voir catalogue en vigueur For price, see current catalogue IEC 2000 Dr
5、oits de reproduction rservs Copyright - all rights reserved International Electrotechnical Commission 3, rue de Varemb Geneva, Switzerland Telefax: +41 22 919 0300 e-mail: inmailiec.ch IEC web site http:/www.iec.ch CODE PRIX PRICE CODE F60598-2-3 Amend. 2 IEC:2000 2 AVANT-PROPOS Le prsent amendement
6、 a t tabli par le sous-comit 34D: Luminaires, du comit dtudes 34 de la CEI: Lampes et quipements associs. Le texte de cet amendement est issu des documents suivants: FDIS Rapport de vote34D/600/FDIS 34D/610/RVD Le rapport de vote indiqu dans le tableau ci-dessus donne toute information sur le vote a
7、yant abouti lapprobation de cet amendement. Le comit a dcid que le contenu de la publication de base et de ses amendements ne sera pas modifi avant 2002-04. A cette date, la publication sera reconduite; supprime; remplace par une dition rvise, ou amende. _ Page 10 Remplacer le titre et le texte du p
8、aragraphe 3.6.3.1 par ce qui suit: 3.6.3.1 Essai de charge statique pour luminaires monts en crosse ou lextrmit des candlabres Le luminaire est install de telle faon que la surface la plus critique soit charge. La surface la plus critique est dtermine par le calcul de la valeur la plus leve du produ
9、it Cd S. o Cd est le coefficient de trane; S est laire de la surface charger (m2). Le coefficient de trane dpend de la forme de la surface. Pour les luminaires pour lesquels le Cd nest pas mesur, la valeur de 1,2 doit tre utilise. NOTE 1 Voir lannexe A pour la mesure de Cd. Les dispositifs de fixati
10、on doivent tre assujettis conformment aux recommandations du fabricant. Une charge constante uniformment rpartie est applique pendant 10 min sur la surface la plus critique. NOTE 2 Voir la figure 1 pour les mthodes de distribution gale de la charge. Lorsque des filets sont utiliss, ils peuvent tre r
11、emplis avec du sable, des billes de plomb ou des petites balles. 60598-2-3 Amend. 2 IEC:2000 3 FOREWORD This amendment has been prepared by subcommittee 34D: Luminaires, of IEC technical committee 34: Lamps and related equipment. The text of this amendment is based on the following documents: FDIS R
12、eport on voting 34D/600/FDIS 34D/610/RVD Full information on the voting for the approval of this amendment can be found in the report on voting indicated in the above table. The committee has decided that the contents of the base publication and its amendments will remain unchanged until 2002-04. At
13、 this date, the publication will be reconfirmed; withdrawn; replaced by a revised edition, or amended. _ Page 11 Replace the title and text of subclause 3.6.3.1 by the following: 3.6.3.1 Static load test for mast arm or post top mounted luminaires The luminaire is mounted in such a way that the most
14、 critical surface is loaded. The most critical surface is determined by calculating the highest value of Cd S where Cd is the drag coefficient; S is the area of the surface to be loaded (m2). The drag coefficient depends on the shape of the surface. For luminaires for which the Cd is not measured th
15、e value of 1,2 shall be taken. NOTE 1 See annex A for measurement of Cd. The means of attachment shall be secured in accordance with the manufacturers instructions. A constant evenly distributed load is applied for 10 min on the most critical surface. NOTE 2 See figure 1 for methods of equal distrib
16、ution of the load. In cases where bags are used, these can be filled with sand, lead shot or small balls. 60598-2-3 Amend. 2 IEC:2000 4 La charge doit tre gale F = 1/2 Rh S Cd V2(N) o Rh est gal 1,225 kg/m3(masse volumique de lair); V est la vitesse du vent (m/s). Les vitesses du vent prendre en com
17、pte en fonction des hauteurs des luminaires doivent tre V = 45 m/s (163 km/h) pour des hauteurs infrieures 8 m; V = 52 m/s (188 km/h) pour des hauteurs comprises entre 8 m et 15 m; V = 57 m/s (205 km/h) pour des hauteurs suprieures 15 m. NOTE Dans certains pays (le Japon, par exemple), la vitesse du
18、 vent est dtermine par des rglementations nationales. Le coefficient de trane est gal 1,2 (ou la valeur exacte mesure selon lannexe A). Aprs lessai, il ne doit y avoir aucun dfaut visible affectant la scurit, pas de dformation permanente de la fixation excdant une pente suprieure de 2 cm/m, et pas d
19、e rotation autour du point de fixation. 3.6.5 Remplacer la troisime phrase du troisime alina et tout le quatrime alina par ce qui suit: Moins de 5 min aprs la rupture, compter les morceaux dans un carr de 50 mm de ct localis approximativement au centre de la zone de plus grosse fracture, mais toujou
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CANCSAE6059823AMD22002AMENDMENT2LUMINAIRES PART23PARTICULARREQUIREMENTS LUMINAIRESFORROADANDSTREETLIGHTINGFIRSTEDITIONPDF

链接地址:http://www.mydoc123.com/p-589836.html