BS ISO 5550-2006 Caseins and caseinates - Determination of moisture content (Reference method)《酪蛋白和酪蛋白酸盐 水含量的测定(参照法)》.pdf
《BS ISO 5550-2006 Caseins and caseinates - Determination of moisture content (Reference method)《酪蛋白和酪蛋白酸盐 水含量的测定(参照法)》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 5550-2006 Caseins and caseinates - Determination of moisture content (Reference method)《酪蛋白和酪蛋白酸盐 水含量的测定(参照法)》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58moisture content (Reference method)ICS 67.100.99Caseins and caseinates Determination of BRITISH STA
2、NDARDBS ISO 5550:2006BS ISO 5550:2006This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 November 2006 BSI 2006ISBN 0 580 49632 5Amendments issued since publicationAmd. No. Date Commentscontract. Users are responsible for its correct applicati
3、on.Compliance with a British Standard cannot confer immunity from legal obligations.National forewordThis British Standard was published by BSI. It is the UK implementation of ISO 5550:2006. It supersedes BS 6248-8:1982 which is withdrawn.The UK participation in its preparation was entrusted to Tech
4、nical Committee AW/5, Chemical analysis of milk and milk products. A list of organizations represented on AW/5 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a Reference numbersISO 5550:2006(E)IDF 78:2006(E)INTERNATIONAL STAND
5、ARD ISO5550IDF78Second edition2006-10-01Caseins and caseinates Determination of moisture content (Reference method) Casines et casinates Dtermination de la teneur en humidit (Mthode de rfrence) BS ISO 5550:2006ii iiiContents Page Foreword iv Foreword. v 1 Scope . 1 2 Terms and definitions. 1 3 Princ
6、iple. 1 4 Apparatus 1 5 Sampling 2 6 Preparation of test sample. 2 7 Procedure 2 7.1 Preparation of the dish. 2 7.2 Test portion . 2 7.3 Determination 2 8 Calculation and expression of results 3 8.1 Calculation. 3 8.2 Expression of results . 3 9 Precision 3 9.1 Interlaboratory tests . 3 9.2 Repeatab
7、ility 3 9.3 Reproducibility 4 10 Test report . 4 Annex A (informative) Interlaboratory tests 5 Annex B (informative) Influence of the size of the casein grains on precision figures 7 Bibliography . 8 BS ISO 5550:2006iv Foreword ISO (the International Organization for Standardization) is a worldwide
8、federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that c
9、ommittee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in acco
10、rdance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requi
11、res approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 5550IDF 78 was prepared by Tec
12、hnical Committee ISO/TC 34, Food products, Subcommittee SC 5, Milk and milk products, and the International Dairy Federation (IDF). It is being published jointly by ISO and IDF. This edition of ISO 5550IDF 78 cancels and replaces ISO 5550:1978, which has been technically revised. BS ISO 5550:2006vFo
13、reword IDF (the International Dairy Federation) is a worldwide federation of the dairy sector with a National Committee in every member country. Every National Committee has the right to be represented on the IDF Standing Committees carrying out the technical work. IDF collaborates with ISO in the d
14、evelopment of standard methods of analysis and sampling for milk and milk products. Draft International Standards adopted by the Action Teams and Standing Committees are circulated to the National Committees for voting. Publication as an International Standard requires approval by at least 50 % of t
15、he IDF National Committees casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. IDF shall not be held responsible for identifying any or all such patent rights. ISO 5550IDF 78 was prepared by the International Dairy Fed
16、eration (IDF) and Technical Committee ISO/TC 34, Food products, Subcommittee SC 5, Milk and milk products. It is being published jointly by IDF and ISO. All work was carried out by the Joint ISO-IDF Action Team Water, of the Standing Committee on Main components in milk, under the aegis of its proje
17、ct leader, Mrs M. Nicolas (FR). This edition of ISO 5550IDF 78 cancels and replaces IDF 78C:1991, which has been technically revised. BS ISO 5550:2006blank1Caseins and caseinates Determination of moisture content (Reference method) 1 Scope This International Standard specifies the reference method f
18、or the determination of the moisture content of all types of caseins and caseinates. 2 Terms and definitions For the purpose of this document, the following terms and definitions apply. 2.1 moisture content loss of mass determined by the procedure described in this International Standard NOTE The mo
19、isture content is expressed as a mass fraction in percent. 3 Principle A test portion is dried at 102 C 2 C then weighed to determine its loss of mass. 4 Apparatus Usual laboratory equipment and, in particular, the following. 4.1 Analytical balance, capable of weighing to the nearest 1 mg, with a re
20、adability of 0,1 mg. 4.2 Drying oven, well ventilated, capable of being maintained at a temperature of 102 C 2 C throughout the working space. 4.3 Flat bottomed dish, made of a material that is non-corrodible under the conditions of the test (e.g. a glass dish with ground-glass cover, or aluminium o
21、r stainless-steel dish), of diameter at least 65 mm (preferably 75 mm) and depth of at least 25 mm, equipped with a tight-fitting lid which can be readily removed. 4.4 Desiccator, containing an effective desiccant (e.g. freshly dried silica gel), with hygrometric indicator. 4.5 Grinding device, for
22、grinding the laboratory sample (if necessary, see 6.4), without development of undue heat and without loss or absorption of moisture. A hammer-mill shall not be used. 4.6 Test sieve, wire cloth, of diameter 200 mm and nominal size of aperture 500 m, with receiver. BS ISO 5550:20062 5 Sampling A repr
23、esentative sample should have been sent to the laboratory. It should not have been damaged or changed during transport or storage. Sampling is not part of the method specified in this International Standard. A recommended sampling method is given in ISO 707IDF 50. Store the sample in such a way that
24、 deterioration and change in composition are prevented. 6 Preparation of test sample 6.1 Thoroughly mix the test sample by repeatedly shaking and inverting the container (if necessary, after having transferred all test sample to an airtight container of sufficient capacity to allow this operation to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO55502006CASEINSANDCASEINATESDETERMINATIONOFMOISTURECONTENTREFERENCEMETHOD 蛋白 盐水 含量 测定 参照 PDF

链接地址:http://www.mydoc123.com/p-587515.html