BS ISO 28057-2014 Dosimetry with solid thermoluminescence detectors for photon and electron radiations in radiotherapy《放射疗法中光子和电子辐射用固体热释光探测器的放射量测定》.pdf
《BS ISO 28057-2014 Dosimetry with solid thermoluminescence detectors for photon and electron radiations in radiotherapy《放射疗法中光子和电子辐射用固体热释光探测器的放射量测定》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 28057-2014 Dosimetry with solid thermoluminescence detectors for photon and electron radiations in radiotherapy《放射疗法中光子和电子辐射用固体热释光探测器的放射量测定》.pdf(52页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS ISO 28057:2014Dosimetry with solidthermoluminescence detectorsfor photon and electronradiations in radiotherapyBS ISO 28057:2014 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of ISO 28057:2014.The UK participation in its preparation was e
2、ntrusted to TechnicalCommittee NCE/2, Radiation protection and measurement.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapp
3、lication. The British Standards Institution 2014. Published by BSI StandardsLimited 2014ISBN 978 0 580 74397 9ICS 13.280Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committe
4、e on 31 March 2014.Amendments issued since publicationDate Text affectedBS ISO 28057:2014 ISO 2014Dosimetry with solid thermoluminescence detectors for photon and electron radiations in radiotherapyDosimtrie avec dtecteurs de thermolumiscence solides pour le photon et rayonnements dlectron en radiot
5、hrapieINTERNATIONAL STANDARDISO28057First edition2014-03-01Reference numberISO 28057:2014(E)BS ISO 28057:2014ISO 28057:2014(E)ii ISO 2014 All rights reservedCOPYRIGHT PROTECTED DOCUMENT ISO 2014All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized
6、 otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester.ISO copyright of
7、ficeCase postale 56 CH-1211 Geneva 20Tel. + 41 22 749 01 11Fax + 41 22 749 09 47E-mail copyrightiso.orgWeb www.iso.orgPublished in SwitzerlandBS ISO 28057:2014ISO 28057:2014(E) ISO 2014 All rights reserved iiiContents PageForeword ivIntroduction v1 Scope . 12 Normative references 13 Terms and defini
8、tions . 24 Rules for the TLD measurement procedure . 94.1 Principle of measurement . 94.2 Measured quantity . 94.3 Measurement cycle . 104.4 Measurement of the absorbed dose to water 124.5 Uncertainty of measurement of the absorbed dose .224.6 Reusability . 224.7 Stability check . 234.8 Staff 235 Re
9、quirements for the TLD system .235.1 General information 235.2 Completeness of the TLD system . 235.3 Requirements for TL detectors 265.4 Requirements for TL-indicating instruments .275.5 Requirements for auxiliary instruments (pre-irradiation annealing device) .325.6 Requirements for the entire TLD
10、 system 325.7 Requirements for the calibration irradiation device.355.8 Requirements for the accompanying papers .355.9 Acceptance tests . 35Bibliography .37BS ISO 28057:2014ISO 28057:2014(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standa
11、rds bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organ
12、izations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.The procedures used to develop this document and those intended for its f
13、urther maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2. www.iso.org/directive
14、sAttention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introd
15、uction and/or on the ISO list of patent declarations received. www.iso.org/patentsAny trade name used in this document is information given for the convenience of users and does not constitute an endorsement.The committee responsible for this document is ISO/TC 85, Nuclear energy, nuclear technologi
16、es, and radiological protection, Subcommittee SC 2, Radiological protection.For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the WTO principles in the Technical Barriers to Trade (TBT) see the fol
17、lowing URL: http:/www.iso.org/iso/home/standards_development/resources-for-technical-work/foreword.htmiv ISO 2014 All rights reservedBS ISO 28057:2014ISO 28057:2014(E)IntroductionThe thermoluminescence dosimetry (TLD) with lithium fluoride (LiF) detectors has several advantages, in particular: small
18、 volumes of the detectors; applicability to continuous and pulsed radiation; fair water equivalency of the detector material; few correction factors needed for absorbed dose determinations.The main disadvantage of thermoluminescence (TL) detectors is, however, that they have to be regenerated by a p
19、re-irradiation annealing procedure. Unfortunately, it is not possible to restore the former response of the detectors perfectly by this annealing. Provided, however, that all detectors of a production batch always undergo the same thermal treatment, one can at least determine the mean alteration of
20、the response of these detectors, with sufficiently small fluctuations of the individual values. From this mean alteration, a correction factor can be derived.The essential aim of this International Standard is to specify the procedures and to carry out corrections which allow one to achieve (1) a re
21、peatability of the indicated value within a fraction of a percent17and thus, (2) a total uncertainty of measurement (including the calibration steps tracing to the primary standards) of a few percent, as in ionization chamber dosimetry.1831256162The specifications in this International Standard comp
22、rise special terms used in TLD, rules for the measurement technique, and requirements for the measurement system. The defined requirements and the testing techniques can, in whole or in part, serve as a basis for stability checks and acceptance tests. The TLD procedures described in this Internation
23、al Standard can be used for photon radiation within the energy range from 20 keV to 50 MeV, including photon brachytherapy, and for electron radiation within the energy range from 4 MeV to 25 MeV, excluding beta radiation brachytherapy. In order to achieve the repeatability and total uncertainty sta
24、ted above, this International Standard is applicable in the dose range above 1 mGy. The upper limit of the minimum measuring range is in the order of magnitude of 10 Gy to 100 Gy. In clinical dosimetry, TL detectors are applied taking into account the requirements of high spatial resolution, i.e. in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO280572014DOSIMETRYWITHSOLIDTHERMOLUMINESCENCEDETECTORSFORPHOTONANDELECTRONRADIATIONSINRADIOTHERAPY

链接地址:http://www.mydoc123.com/p-586877.html