BS EN 61280-2-1-2010 Fibre optic communication subsystem test procedures - Digital systems - Receiver sensitivity and overload measurement《光纤通信子系统试验规程 数字系统 接收器灵敏度和过载测量》.pdf
《BS EN 61280-2-1-2010 Fibre optic communication subsystem test procedures - Digital systems - Receiver sensitivity and overload measurement《光纤通信子系统试验规程 数字系统 接收器灵敏度和过载测量》.pdf》由会员分享,可在线阅读,更多相关《BS EN 61280-2-1-2010 Fibre optic communication subsystem test procedures - Digital systems - Receiver sensitivity and overload measurement《光纤通信子系统试验规程 数字系统 接收器灵敏度和过载测量》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationFibre optic communication subsystem test proceduresPart 2-1: Digital systems Receiver sensitivity and overload measurementBS EN 61280-2-1:2010National forewordThis British Standa
2、rd is the UK implementation of EN 61280-2-1:2010. It isidentical to IEC 61280-2-1:2010. It supersedes BS EN 61280-2-1:1999 whichis withdrawn.The UK participation in its preparation was entrusted by Technical CommitteeGEL/86, Fibre optics, to Subcommittee GEL/86/3, Fibre optic systems andactive devic
3、es.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2010ISBN 978 0 580 62668 5ICS 33.180.01Compliance with a
4、British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 30 June 2010.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 61280-2-1:2010EUROPEAN STANDARD EN 6
5、1280-2-1 NORME EUROPENNE EUROPISCHE NORM May 2010 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2010 CENELEC - All rights of explo
6、itation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61280-2-1:2010 E ICS 33.180.01 Supersedes EN 61280-2-1:1999English version Fibre optic communication subsystem test procedures - Part 2-1: Digital systems - Receiver sensitivity and overload measurement (IEC 612
7、80-2-1:2010) Procdures dessai des sous-systmes de tlcommunications fibres optiques - Partie 2-1: Systmes numriques - Mesure de la sensibilit et de la surcharge dun rcepteur (CEI 61280-2-1:2010) Prfverfahren fr Lichtwellenleiter-Kommunikationsuntersysteme - Teil 2-1: Prfverfahren fr digitale Systeme
8、- Messung der Empfindlichkeitsschwelle und der maximalen Eingangsleistung von Empfngern (IEC 61280-2-1:2010) This European Standard was approved by CENELEC on 2010-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this Euro
9、pean Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (Eng
10、lish, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria,
11、 Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingd
12、om. EN 61280-2-1:2010 - 2 - Foreword The text of document 86C/881/CDV, future edition 2 of IEC 61280-2-1, prepared by SC 86C, Fibre optic systems and active devices, of IEC TC 86, Fibre optics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61280-2-1 on 2010-04-01.
13、This European Standard supersedes EN 61280-2-1:1999. The main changes with respect to EN 61280-2-1:1999 are listed below: revised to include the requirements associated with data communication equipment, regenerators and amplifiers; the term “jumper lead” has been replaced by “test cord”: a section
14、for definitions has been added; a section on measurement uncertainties has been added. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. Th
15、e following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-01-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2013-04-01 _ Endorsemen
16、t notice The text of the International Standard IEC 61280-2-1:2010 was approved by CENELEC as a European Standard without any modification. _ BS EN 61280-2-1:2010 2 61280-2-1 IEC:2010(E) CONTENTS 1 Scope and object5 2 Terms and definitions .5 3 Apparatus.6 3.1 General .6 3.2 BER test set 6 3.2.1 Dat
17、a generator 7 3.2.2 Error counter .7 3.3 Optical power meter 7 3.4 Variable optical attenuator.7 3.5 Optical splitter .7 3.6 Test cords .7 3.7 Optical transmit interface.7 4 Equipment under test (EUT) .8 5 Test procedure .8 5.1 Operating conditions and test environment8 5.2 Connector end-face cleani
18、ng.8 5.3 Measurement of input sensitivity .8 5.3.1 Optical input power calibration.10 5.3.2 BER or EBR determination10 5.4 Measurement of overload level11 5.4.1 Power level calibration.11 5.4.2 Overload level determination .12 5.4.3 Calculation of overload level12 6 Measurement uncertainties.13 7 Te
19、st results 13 7.1 Required information .13 7.2 Available information.13 Bibliography14 Figure 1 Optical fibre system .5 Figure 2 Setup for the measurement of input sensitivity of a receive terminal.9 Figure 3 Setup for the measurement of input sensitivity of an amplifier or regenerator .9 Figure 4 S
20、etup for the measurement of overload level for a receive terminal11 Figure 5 Setup for the measurement of overload level for an amplifier or regenerator 12 Table 1 Minimum monitoring time.10 BS EN 61280-2-1:201061280-2-1 IEC:2010(E) 5 FIBRE OPTIC COMMUNICATION SUBSYSTEM TEST PROCEDURES Part 2-1: Dig
21、ital systems Receiver sensitivity and overload measurement 1 Scope and object This part of IEC 61280 describes the test procedures applicable to digital fibre optic communication and data systems. The object of this test procedure is to measure the minimum and maximum optical powers required and all
22、owed at the optical input port of a fibre optic system to ensure its operation within specified limits. Another objective is to verify that the guaranteed error performance is obtained at the minimum and the maximum optical input powers specified by the terminal equipment manufacturer. Figure 1 show
23、s the typical elements associated with optical fibre systems. Optical amplifiers or regenerators may be used in long haul telecom systems, but are not usually associated with data transport systems such as Ethernet, etc. In bi-directional systems the transmitter and corresponding receiver are usuall
24、y co-located, as indicated by the dotted lines. This specification is concerned with the characteristics of the optical input interface of the receiver, amplifier or regenerator shown. Measurement PointOptical Fibre LinkSystemOutput OpticalReceiveInterfaceReceiveEquipmentSystemInput OpticalTransmitI
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN61280212010FIBREOPTICCOMMUNICATIONSUBSYSTEMTESTPROCEDURESDIGITALSYSTEMSRECEIVERSENSITIVITYANDOVERLOADMEASUREMENT

链接地址:http://www.mydoc123.com/p-577229.html