BS EN 50464-2-2-2007 Three-phase oil-immersed distribution transformers 50 Hz from 50 kVA to 2500 kVA with highest voltage for equipment not exceeding 36 kV Distribution transformeo.pdf
《BS EN 50464-2-2-2007 Three-phase oil-immersed distribution transformers 50 Hz from 50 kVA to 2500 kVA with highest voltage for equipment not exceeding 36 kV Distribution transformeo.pdf》由会员分享,可在线阅读,更多相关《BS EN 50464-2-2-2007 Three-phase oil-immersed distribution transformers 50 Hz from 50 kVA to 2500 kVA with highest voltage for equipment not exceeding 36 kV Distribution transformeo.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV
2、 Part 2-2: Distribution transformers with cable boxes on the high-voltage and/or low-voltage side Cable boxes type 1 for use on distribution transformers meeting the requirements of EN 50464-2-1The European Standard EN 50464-2-2:2007 has the status of a British StandardICS 29.180Three-phase oil-imme
3、rsed distribution BRITISH STANDARDBS EN 50464-2-2:2007BS EN 50464-2-2:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 August 2007 BSI 2007ISBN 978 0 580 57699 7Amendments issued since publicationAmd. No. Date Commentscontract. Users ar
4、e responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations. National forewordThis British Standard is the UK implementation of EN 50464-2-2:2007. It supersedes BS 7821-2.2:1998 which is withdrawn.The UK participation in its preparation
5、was entrusted to Technical Committee PEL/14, Power transformers.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a EUROPEAN STANDARD EN 50464-2-2NORME EUROPENNE EUROPISCHE NO
6、RM April 2007 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any m
7、eans reserved worldwide for CENELEC members. Ref. No. EN 50464-2-2:2007 E ICS 29.180 Supersedes HD 428.2.2 S1:1997English version Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 2-2: Distribution transfo
8、rmers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes type 1 for use on distribution transformers meeting the requirements of EN 50464-2-1 Transformateurs triphass de distribution immergs dans lhuile, 50 Hz, de 50 kVA 2 500 kVA, de tension la plus leve pour le matriel ne d
9、passant pas 36 kV - Partie 2-2: Transformateurs de distributionraccords par botes cble ct haute tension et/ou ct basse tension - Botes cbles de type 1 pour utilisation sur transformateurs de distribution conformes aux exigences de la EN 50464-2-1 lgefllte Drehstrom-Verteilungstransformatoren 50 Hz,
10、50 kVA bis 2 500 kVA, mit einer hchsten Spannung fr Betriebsmittel bis 36 kV - Teil 2-2: Verteilungstransformatoren mit Kabelanschlussksten auf der Ober- und/oder Unterspannungsseite - Kabelanschlussksten Typ 1 fr Verteilungstransformatoren nach EN 50464-2-1 This European Standard was approved by CE
11、NELEC on 2006-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national stand
12、ards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and noti
13、fied to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuani
14、a, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 50464-2-2:2007 2 Foreword The text of the Harmonization Document HD 428.2.2 S1:1997, prepared by the Technical Committee CENELEC TC 14, Power transforme
15、rs, was submitted to the formal vote for conversion into a European Standard and was approved by CENELEC as EN 50464-2-2 on 2006-12-01. The following date was fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement
16、 (dop) 2007-12-01 The EN 50464 series consists of the following parts, under the general title “Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV”: Part 1 General requirements Part 2-1 Distribution transformers w
17、ith cable boxes on the high-voltage and/or low-voltage side General requirements Part 2-2 Distribution transformers with cable boxes on the high-voltage and/or low-voltage side Cable boxes type 1 for use on distribution transformers meeting the requirements of EN 50464-2-1 Part 2-3 Distribution tran
18、sformers with cable boxes on the high-voltage and/or low-voltage side Cable boxes type 2 for use on distribution transformers meeting the requirements of EN 50464-2-1 Part 3 Determination of the power rating of a transformer loaded with non-sinusoidal currents Part 4 Requirements and tests concernin
19、g pressurised corrugated tanks 3 EN 50464-2-2:2007 Contents 1 Scope4 2 Normative references4 3 Definitions4 4 Electrical requirements and clearances 5 4.1 General. 5 4.2 High voltage enclosures 7 4.3 Low voltage boxes 8 5 Design considerations.7 5.1 General. 8 5.2 Terminal nuts and stems . 8 5.3 Pro
20、vision for glanding cables. 8 5.4 Termination of cables within enclosure 8 6 Testing 7 6.1 Type tests . 9 6.2 Routine tests. 9 7 Earthing of cable boxes 8 Figure Figure 1 Clearance distances .5 Table Table 1 Three phase cable box, Type 1.6 EN 50464-2-2:2007 4 1 Scope This European Standard specifies
21、 the requirements for cable boxes, Type 1, in which the cable cores are terminated. The cable boxes are suitable for use on transformers defined in EN 50464-2-1, “Distribution Transformers with Cable Boxes“, for side mounted or cover mounted use. The cable boxes are suitable for operation indoors an
22、d outdoors under environmental conditions specified in EN 50464-1. Important design and construction requirements of the cable boxes are given. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cit
23、ed applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50180 Bushings above 1 kV up to 36 kV and from 250 A to 3,15 kA for liquid filled transformers EN 50181 1997 Plug-in type bushings above 1 kV up to 36 kV and from 250 A to 1,25 kA
24、 for equipment other than liquid filled transformers EN 50336 2002 Bushings for transformers and reactor cable boxes not exceeding 36 kV EN 50386 2002 Bushings up to 1 kV and from 250 A to 5 kA, for liquid filled transformers EN 50387 2002 Busbar bushings up to 1 kV and from 1,25 kA to 5 kA, for liq
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN50464222007THREEPHASEOILIMMERSEDDISTRIBUTIONTRANSFORMERS50HZFROM50KVATO2500KVAWITHHIGHESTVOLTAGEFOREQUIPMENTNOTEXCEEDING36KVDISTRIBUTIONTRANSFORMEOPDF

链接地址:http://www.mydoc123.com/p-574951.html