BS EN 50216-5-2002 Power transformer and reactor fittings - Liquid level pressure and flow indicators pressure relief devices and dehydrating breathers《电力变压器和反应堆配件 液位、压力装置和流量指示计》.pdf
《BS EN 50216-5-2002 Power transformer and reactor fittings - Liquid level pressure and flow indicators pressure relief devices and dehydrating breathers《电力变压器和反应堆配件 液位、压力装置和流量指示计》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50216-5-2002 Power transformer and reactor fittings - Liquid level pressure and flow indicators pressure relief devices and dehydrating breathers《电力变压器和反应堆配件 液位、压力装置和流量指示计》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 50216-5:2002Incorporating Amendments Nos. 1, 2 and 3Power transformer and reactor fittings Part 5: Liquid level, pressure and flow indicators, pressure relief devices and dehydrating breathersThe European Standard EN 50216-5:2002, with the incorporation of amendments A1:2002, A
2、2:2005 and A3:2006, has the status of a British StandardICS 29.180g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 50216-5:2002This British Sta
3、ndard, having been prepared under the direction of the Electrotechnical Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 12 April 2002 BSI 2006ISBN 0 580 39502 2National forewordThis British Standard was published by BSI. It is
4、 the UK implementation of EN 50216-5:2002, incorporating amendments A1:2002, A2:2005 and A3:2006.The start and finish of text introduced or altered by amendment is indicated in the text by tags !“. Tags indicating changes to CENELEC text carry the number of the CENELEC amendment. For example, text a
5、ltered by CENELEC amandment A1 is indicated in the text by !“.The UK participation in its preparation was entrusted to Technical Committee PEL/14, Power transformers.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to
6、 include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot of itself confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date Comments14727 4 November 2003 See national foreword16296
7、30 June 2006 See national foreword16806 29 December 2006 See national forewordEUROPEAN STANDARD EN 50216-5 January 2002 NORME EUROPENNE +A1 December 2002 EUROPISCHE NORM +A2 May 2005 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europ
8、isches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2002 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50216-5:2002 ICS 29.180 English version Power transformer and reactor fitt
9、ings Part 5: Liquid level, pressure and flow indicators, pressure relief devices and dehydrating breathers Accessoires pour transformateurs de puissance et bobines dinductance Partie 5: Indicateurs de niveau de liquide isolant, manomtres et indicateurs de circulation de liquide isolant, limiteurs de
10、 pression et asscheurs dair Zubehr fr Transformatoren und Drosselspulen Teil 5: Flssigkeitsstandanzeiger, Druckanzeigeeinrichtungen und Durchflussmesser, Druckentlastungsventile und Luftentfeuchter This European Standard was approved by CENELEC on 2001-09-25. CENELEC members are bound to comply with
11、 the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat
12、 or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the off
13、icial versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slove
14、nia, Spain, Sweden, Switzerland and United Kingdom. October 2006 +A3 Foreword This European Standard was prepared by the Technical Committee CENELEC TC 14, Power transformers. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50216-5 on 2001-09-2-25. The follow
15、ing dates were fixed: - latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2002-10-01 - latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2004-10-01 EN EN 50216-5 is
16、 to be read in conjunction with EN EN 50216-1. Foreword to amendment A1 This amendment was prepared by the Technical Committee CENELEC TC 14, Power transformers. The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as amendment A1 to EN 50216-5:2002 on 2
17、002-11-01. The following dates were fixed: - latest date by which the amendment has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2003-11-01 - latest date by which the national standards conflicting with the amendment have to be withdraw
18、n (dow) 2005-11-01 Foreword to amendment A2 This amendment to the European Standard EN 50216-5:2002 was prepared by the Technical Committee CENELEC TC 14, Power transformers. The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as amendment A2 to EN 5021
19、6-5:2002 on 2004-12-01. The following dates were fixed: - latest date by which the amendment has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2005-12-01 - latest date by which the national standards conflicting with the amendment have t
20、o be withdrawn (dow) 2007-12-01 EN 50216-5:2002 as well as this amendment are to be read in conjunction with EN 50216-1:2002. EN 50216-5:2002 2 Foreword to amendment A3 This amendment to the European Standard EN 50216-5:2002 was prepared by the Technical Committee CENELEC TC 14, Power transformers.
21、The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as amendment A3 to EN 50216-5:2002 on 2006-09-01. This amendment supersedes EN 50216-5:2002/A1:2002. The following dates were fixed: latest date by which the amendment has to be implementedat national
22、level by publication of an identical national standard or by endorsement (dop) 2007-09-01 latest date by which the national standards conflicting with the amendment have to be withdrawn (dow) 2009-09-01 _ EN 50216-5:2002 3 Contents Page 1 Scope5 2 Normative references 5 3 Direct reading dial type li
23、quid level indicators5 3.1 General .5 3.2 Electrical characteristics of switch 6 3.3 Tests 6 4 Liquid pressure gauges - Differential pressure gauges .7 4.1 General .7 4.2 Electrical characteristics of switch 7 4.3 Tests 8 5 Liquid flow indicators8 5.1 General 8 5.2 Electrical characteristics of swit
24、ch 9 5.3 Tests 10 6 Pressure relief devices 10 6.1 General 10 6.2 Operating limits 6.3 Dimensions 6.4 Operating performance 13 6.5 Manufacturing features 13 6.6 Tests 14 7 Dehydrating breathers. 14 7.1 General 14 7.2 Selection criteria 15 7.3 Fixing arrangement and overall dimensions 15 7.4 Breather
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN5021652002POWERTRANSFORMERANDREACTORFITTINGSLIQUIDLEVELPRESSUREANDFLOWINDICATORSPRESSURERELIEFDEVICESANDDEHYDRATINGBREATHERS

链接地址:http://www.mydoc123.com/p-574663.html