BS EN 12152-2002 Curtain walling - Air permeability - Performance requirements and classification《幕墙 透气率 性能要求和分类》.pdf
《BS EN 12152-2002 Curtain walling - Air permeability - Performance requirements and classification《幕墙 透气率 性能要求和分类》.pdf》由会员分享,可在线阅读,更多相关《BS EN 12152-2002 Curtain walling - Air permeability - Performance requirements and classification《幕墙 透气率 性能要求和分类》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 12152:2002 Curtain walling Air permeability Performance requirements and classification The European Standard EN 12152:2002 has the status of a British Standard ICS 91.060.10 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBS EN 12152:2002 This British St
2、andard, having been prepared under the direction of the Building and Civil Engineering Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 26 March 2002 BSI 26 March 2002 ISBN 0 580 39416 6 National foreword This British Standard
3、is the official English language version of EN 12152:2002. The UK participation in its preparation was entrusted by Technical Committee B/538, Doors, windows, shutters, hardware and curtain walling, to Subcommittee B/538/6, Curtain walling, which has the responsibility to: A list of organizations re
4、presented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Corre
5、spondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does no
6、t of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promul
7、gate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 10, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publicat
8、ion Amd. No. Date CommentsEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM EN12152 February2002 ICS91.060.10 Englishversion CurtainwallingAirpermeabilityPerformancerequirements andclassification FaadesrideauxPermabilitlairExigencesde performanceetclassification VorhangfassadenLuftdurchlssigkeit Leistu
9、ngsanforderungenundKlassifizierung ThisEuropeanStandardwasapprovedbyCENon9November2001. CENmembersareboundtocomplywiththeCEN/CENELECInternalRegulationswhichstipulatetheconditionsforgivingthisEurope an Standardthestatusofanationalstandardwithoutanyalteration.Uptodatelistsandbibliographicalreferencesc
10、oncernings uchnational standardsmaybeobtainedonapplicationtotheManagementCentreortoanyCENmember. ThisEuropeanStandardexistsinthreeofficialversions(English,French,German).Aversioninanyotherlanguagemadebytra nslation undertheresponsibilityofaCENmemberintoitsownlanguageandnotifiedtotheManagementCentreh
11、asthesamestatusasthe official versions. CENmembersarethenationalstandardsbodiesofAustria,Belgium,CzechRepublic,Denmark,Finland,France,Germany,Greece, Iceland,Ireland,Italy,Luxembourg,Malta,Netherlands,Norway,Portugal,Spain,Sweden,SwitzerlandandUnitedKingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMIT
12、EUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2002CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.EN12152:2002EEN12152:2002(E) 2 Contents page Foreword3 1 Scope .4 2 Normativereferences .4 3 Termsand
13、definitions .4 4 Requirements .5 5 Testmethod6 6 Classification 6 Bibliography.10EN12152:2002(E) 3 Foreword ThisdocumentEN12152:2002hasbeenpreparedbyTechnicalCommitteeCEN/TC33“Doors,windows, shutters,buildinghardwareandcurtainwalling”,thesecretariatofwhichisheldbyAFNOR. ThisEuropeanStandardshallbegi
14、venthestatusofanationalstandard,eitherbypublicationofan identicaltextorbyendorsement,atthelatestbyAugust2002,andconflictingnationalstandardsshallbe withdrawnatthelatestbyAugust2002. ThisEuropeanStandardispartofaseriesofEuropeanStandardsdedicatedtocurtainwallingproducts andderivesfromperformancerequi
15、rements. ThisEuropeanStandardformspartofaseriesofcurtainwallingstandardsasspecifiedintheProduct StandardprEN13830. AccordingtotheCEN/CENELECInternalRegulations,thenationalstandardsorganizationsofthefollowing countriesareboundtoimplementthisEuropeanStandard:Austria,Belgium,CzechRepublic,Denmark, Finl
16、and,France,Germany,Greece,Iceland,Ireland,Italy,Luxembourg,Malta,Netherlands,Norway, Portugal,Spain,Sweden,SwitzerlandandtheUnitedKingdom.EN12152:2002(E) 4 1 Scope ThisEuropeanStandardspecifiesrequirementsandclassificationofairpermeabilityofbothfixedand openablepartsofcurtainwalling,underpositiveand
17、negativestaticairpressure. NOTEThisEuropeanStandardappliestocurtainwallingasspecifiedinprEN13830. 2 Normativereferences ThisEuropeanStandardincorporatesbydatedorundatedreference,provisionsfromotherpublications. Thesenormativereferencesarecitedattheappropriateplacesinthetext,andthepublicationsarelist
18、ed hereafter.Fordatedreferences,subsequentamendmentstoorrevisionsofanyofthesepublicationsapply tothisEuropeanStandardonlywhenincorporatedinitbyamendmentorrevision.Forundatedreferences thelatesteditionofthepublicationreferredtoapplies(includingamendments). EN12153, CurtainwallingAirpermeabilityTestme
19、thod. EN12207, WindowsanddoorsAirpermeabilityClassification. prEN13119, CurtainwallingTerminology. prEN13830, CurtainwallingProductStandard. ENV199124, Eurocode1:BasisofdesignandactionsonstructuresPart24:Actionsonstructures Windaction. 3 Termsanddefinitions ForthepurposesofthisEuropeanStandard,thete
20、rmsanddefinitionsgiveninprEN13119togetherwith thefollowingapply: 3.1 testpressure differentialairpressurebetweenthetwofacesofthetestspecimen,expressedinPascals(Pa) 3.2 positivepressure whentheouterfaceissubjectedtohigherairpressurethantheinnerface 3.3 negativepressure whentheouterfaceissubjectedtolo
21、werairpressurethantheinnerface 3.4 airpermeability passageofairthroughthecurtainwallingwhensubjectedtopositiveornegativeairpressure Thevolumebeingexpressedasarateincubicmetresperhour(m 3 /h),thisratebeingrelatedtotheoverall areaofthecurtainwalling.Alternatively,theratecanberelatedtothemetrelengthofj
22、oint.EN12152:2002(E) 5 3.5 fixedjoint alljointsexceptopenablejointsofthecurtainwalling(seeFigure3) 3.6 fixedjointlength sumofthelengthofallfixedjointswithinthecurtainwallingmeasuredalongthelineoftheairseal/barrier. Whereawindowisincludedwithinthecurtainwalling,thelengthoftheperimeterjointshallbeincl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN121522002CURTAINWALLINGAIRPERMEABILITYPERFORMANCEREQUIREMENTSANDCLASSIFICATION 幕墙 透气 率性 要求 分类 PDF

链接地址:http://www.mydoc123.com/p-570103.html