BS 6898-1987 Specification for glass centrifuge tubes for general laboratory use《实验室通用玻璃离心试管规范》.pdf
《BS 6898-1987 Specification for glass centrifuge tubes for general laboratory use《实验室通用玻璃离心试管规范》.pdf》由会员分享,可在线阅读,更多相关《BS 6898-1987 Specification for glass centrifuge tubes for general laboratory use《实验室通用玻璃离心试管规范》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 6898:1987 Specification for Glass centrifuge tubes for general laboratory use UDC 542.2.7:541.18.043.3:542.1BS6898:1987 This British Standard, having been prepared under the directionof the Laboratory Apparatus Standards Committee,was published underthe authority of the BoardofBS
2、I and comes intoeffecton 30 October 1987 BSI 11-1999 The following BSI references relate to the work on this standard: Committee reference LBC/25 Draft for comment 86/52987 DC ISBN 0 580 16185 4 Committees responsible for this British Standard The preparation of this British Standard was entrusted b
3、y the Laboratory Apparatus Standards Committee (LBC/-) to Technical Committee LBC/25, upon which the following bodies were represented: Association of Scientific, Technical and Managerial Staffs British Laboratory Ware Association CLEAPSE Chemical Industries Association Department of Health and Soci
4、al Security Glass Manufacturers Federation Institute of Medical Laboratory Sciences Institute of Science Technology Royal Society of Chemistry Amendments issued since publication Amd. No. Date of issue CommentsBS6898:1987 BSI 11-1999 i Contents Page Committees responsible Inside front cover Foreword
5、 ii 1 Scope 1 2 Definition 1 3 Designation 1 4 Sizes 1 5 Material 1 6 Dimensions 1 7 Details of construction 2 8 Inscriptions 2 9 Package labelling 2 Figure 1 Dimensions of tubes 3 Table 1 Dimensions for tubes 1 Table 2 Dimensions for the cone of conical bottom tubes 1 Publications referred to Insid
6、e back coverBS6898:1987 ii BSI 11-1999 Foreword This British Standard has been prepared under the direction of the Laboratory Apparatus Standards Committee and deals with a product not previously covered by a British Standard. The standard has been prepared to provide a limited range of glass centri
7、fuge tubes, with either rounded or conical bottoms, for general laboratory use. The requirements in this standard are designed to provide tubes that: a) for swing-out head centrifuges, are strong enough to withstand the forces of an acceleration of up to35000m/s 2 , i.e.3500times the acceleration du
8、e to the earths gravity; b) for fixed angle head rotor centrifuges, will withstand up to30000m/s 2 , in regular use. NOTECertain tougher glasses are capable of withstanding the forces of an acceleration in excess of these values. The tubes have been designed with sufficient ullage space to permit th
9、eir use in centrifuges with swing-out heads. Centrifuge manufacturers recommendations should be followed when the tubes identified in this standard are used in fixed angle headed centrifuges. Requirements for laboratory centrifuges are specified in BS4402. WARNING. Particular attention should be pai
10、d to the use of correct size of shield/bucket and cushion profile. Failure to observe these details will considerably reduce safe working limits. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct ap
11、plication. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 to 4, an inside back cover and a back cover. This standard has been updated (see copyright da
12、te) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS6898:1987 BSI 11-1999 1 1 Scope This British Standard specifies requirements for a limited range of two types of glass centrifuge tubes for general laboratory use. The two types sp
13、ecified are: a) graduated or ungraduated glass centrifuge tubes with a rounded bottom; b) graduated or ungraduated glass centrifuge tubes with a conical bottom. NOTE 1The two types are shown in Figure 1. The nominal volumes covered are 6mL, 9mL, 13mL, 25 mLand40mL (seeclause3). NOTE 2The nominal vol
14、umes indicated are those representative of the actual volume below the fill line.Traditionally these were referred to as5mL,10mL,15mL,25mL and50mL. The glass centrifuge tubes specified in this British Standard are suitable for use with solutions of apparent density up to1.2g/mLat20 C and are designe
15、d to withstand the forces due to an acceleration of35000m/s 2 . NOTE 3The titles of the publications referred to in this standard are listed on the inside back cover. 2 Definition For the purposes of this British Standard the following definition applies. nominal volume volume below the upper line s
16、ee8.1 c) above which the tube should not be filled 3 Designation The tubes shall be designated by their nominal volume in millilitres. 4 Sizes The requirements of this British Standard shall apply to the series of glass centrifuge tubes given in Table 1. 5 Material The glass centrifuge tubes shall b
17、e made from colourless medium wall thickness borosilicate glass3.3complying with BS2598-1, or from soda-lime-silica glass or other glass of at least equivalent strength. NOTEThe tubes should be as free as possible from visible defects and reasonably free from internal stress. 6 Dimensions 6.1 Actual
18、 volume The actual volume shall be 10%of the nominal volume. The nominal volume shall be indicated as specified in8.1 b) and as shown in Figure 1. 6.2 Length The length, h 1 , shall be as given in Table 1. 6.3 External diameter The external diameter and the tolerance on the external diameter shall b
19、e as given in Table 1 and in BS5895. Table 1 Dimensions for tubes 6.4 Wall thickness The wall thickness and the tolerance on the wall thickness shall be as given in BS5895for the corresponding medium wall tubing. 6.5 Height of cone In the case of the conical bottom glass centrifuge tubes, the nomina
20、l height, h 3 , of the cone from the base shall be as given in Table 2. Table 2 Dimensions for the cone of conical bottom tubes 6.6 Apex of the cone In the case of the conical bottom glass centrifuge tubes, the apex of the cone shall be not less than0.2times the internal radius, r, of the tube, as s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS68981987SPECIFICATIONFORGLASSCENTRIFUGETUBESFORGENERALLABORATORYUSE 实验室 通用 玻璃 离心 试管 规范 PDF

链接地址:http://www.mydoc123.com/p-546351.html