BS 6092-9-1981 Methods of sampling and test for sodium and potassium silicates for industrial use - Determination of iron content《工业用硅酸钠和硅酸钾取样和试验方法 第9部分 铁含量测定》.pdf
《BS 6092-9-1981 Methods of sampling and test for sodium and potassium silicates for industrial use - Determination of iron content《工业用硅酸钠和硅酸钾取样和试验方法 第9部分 铁含量测定》.pdf》由会员分享,可在线阅读,更多相关《BS 6092-9-1981 Methods of sampling and test for sodium and potassium silicates for industrial use - Determination of iron content《工业用硅酸钠和硅酸钾取样和试验方法 第9部分 铁含量测定》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 6092-9: 1981 ISO 3201:1975 Methods of Sampling and test for sodium and potassium silicates for industrial use Part 9: Determination of iron content ISO title: Sodium and potassium silicates for industrial use Determination of iron content 1,10-Phenanthroline photometric method NO
2、TEIt is recommended that this Part be read in conjunction with the information in the “Generalintroduction” published separately as BS6092-0. UDC 661.683/.684:546.32284 + 546.33284:543.42.062:546.72BS6092-9:1981 This British Standard, having been prepared under the directionof the Chemicals Standard
3、s Committee, was published under the authorityofthe Executive Boardand comes into effect on 27 February 1981 BSI 11-1999 The following BSI references relate to the work on this standard: Committee reference CIC/22 Draft for comment 73/55424 DC ISBN 0 580 12043 0 National foreword This Part of BS6092
4、 is identical with ISO3201 “Sodium and potassium silicates for industrial use Determination of iron content 1, 10-Phenanthroline photometric method”, published in1975 by the International Organization for Standardization (ISO). Terminology and conventions. The text of the International Standard has
5、been approved as suitable for publication as a British Standard without deviation. Some terminology and certain conventions are not identical with those used in British Standards; attention is especially drawn to the following. The comma has been used throughout as a decimal marker. In British Stand
6、ards it is current practice to use a full point on the baseline as the decimal marker. Where the words “International Standard” appear, referring to this standard, they should be read as “British Standard”. Additional information Water. Water complying with the requirements of clause4 is specified i
7、n BS3978 “Water for laboratory use”. In the revised edition of BS3984:1966 “Sodium silicates” the mass of the test portion (see6.1) and the volume of the test solution (see6.4.1) taken for colour development (see6.4.2) will be adjusted so as to fit the method to the specification limits. WARNING. Hy
8、droxylammonium chloride specified in4.2 is corrosive and irritant. Avoid contact with eyes and skin. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard
9、 does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 and 2, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporate
10、d. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date of issue CommentsBS6092-9:1981 BSI 11-1999 i Contents Page National foreword Inside front cover 1 Scope 1 2 Field of application 1 3 Principle 1 4 Reagents 1 5 Apparatus 1 6
11、Procedure 1 7 Expression of results 2 8 Test report 2 Publications referred to Inside back coverii blankBS6092-9:1981 BSI 11-1999 1 1 Scope This International Standard specifies a 1, 10-phenanthroline photometric method for the determination of iron content of sodium and potassium silicates for indu
12、strial use. 2 Field of application The method is applicable to products having iron contents greater than2mg/kg. 3 Principle Prior reduction of the trivalent iron by hydroxylammonium chloride. Formation of the divalent iron/1, 10-phenanthroline complex in a buffered medium. Photometric measurement o
13、f the coloured complex at a wavelength of about510nm. 4 Reagents During the analysis, use only reagents of recognized analytical reagent grade and only distilled water or water of equivalent purity. 4.1 Hydrochloric acid, approximately 2N solution. 4.2 Hydroxylammonium chloride (NH 2 OH.HCl), 100g/l
14、 solution. 4.3 Buffer solution, pH 4,9. Dissolve 272 g of sodium acetate trihydrate (CH 3 COONa.3H 2 O) in approximately 500ml of water. Add 240ml of glacial acetic acid approximately 1,05g/ml, 99 to 100% (m/m) or about17,4N to the solution, dilute to 1000ml and mix. 4.4 Bromine water, saturated at
15、room temperature. 4.5 1,10-Phenanthroline hydrochloride monohydrate (C 12 H 8 N 2 .HCl.H 2 O), 2,5g/l solution. This reagent may be replaced by 1, 10-phenanthroline monohydrate (C 12 H 8 N 2 .H 2 O), 2,5g/l solution. 4.6 Iron, standard solution corresponding to 0,200g of Fe per litre. Dissolve 1,404
16、3g of ammonium iron(II) sulphate hexahydrate (NH 4 ) 2 Fe(SO 4 ) 2 .6H 2 O, weighed to the nearest 0,0001g, in 200ml of water. Add 20ml of sulphuric acid, approximately 1,84g/ml, cool to room temperature, dilute to the mark in a 1000ml one-mark volumetric flask and mix. 4.7 Iron, standard solution c
17、orresponding to0,010g of Fe per litre. Transfer 25,0ml of the standard iron solution (4.6) to a500ml one-mark volumetric flask, dilute to the mark and mix. Prepare this solution at the time of use. 1 ml of this standard solution contains 0,010mg of Fe. 4.8 Methyl orange, 0,5g/l solution. 5 Apparatus
18、 Ordinary laboratory apparatus and: 5.1 Spectrophotometer or 5.2 Photoelectric absorptiometer, fitted with filters providing maximum transmission between500 and520nm. 5.3 Platinum crucible, with lid. Upper diameter about 30mm, height about 30mm. 6 Procedure 6.1 Test portion Weigh, to the nearest 0,0
19、1 g, in a weighing bottle fitted with a ground glass closure, a quantity of the test sample corresponding to approximately 5g of the anhydrous product. 6.2 Blank test Pour 25ml of water, a volume of the hydrochloric acid solution (4.1) 15ml in excess of that used to neutralize the test portion (see6
20、.4.1), 5drops of the methyl orange solution (4.8) and 5ml of the bromine water (4.4) (to decolorize the indicator) into a 600ml beaker. Boil for 5min, cool to room temperature and transfer quantitatively to a 250ml one-mark volumetric flask. Dilute to the mark, mix, and then proceed as specified in6
21、.4.2. 6.3 Preparation of the calibration curve 6.3.1 Preparation of the standard colorimetric solutions, relating to photometric measurements carried out with cells of 4cm or 5cm optical path length. Into a series of five 100ml one-mark volumetric flasks, transfer the quantities of the standard iron
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS609291981METHODSOFSAMPLINGANDTESTFORSODIUMANDPOTASSIUMSILICATESFORINDUSTRIALUSEDETERMINATIONOFIRONCONTENT

链接地址:http://www.mydoc123.com/p-545720.html