《ASTM G61-1986(2009) Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements for Localized Corrosion Susceptibility of Iron- Nickel- or Cobalt-Based All.pdf》由会员分享,可在线阅读,更多相关《ASTM G61-1986(2009) Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements for Localized Corrosion Susceptibility of Iron- Nickel- or Cobalt-Based All.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: G 61 86 (Reapproved 2009)Standard Test Method forConducting Cyclic Potentiodynamic PolarizationMeasurements for Localized Corrosion Susceptibility ofIron-, Nickel-, or Cobalt-Based Alloys1This standard is issued under the fixed designation G 61; the number immediately following the desi
2、gnation indicates the year of originaladoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a procedur
3、e for conductingcyclic potentiodynamic polarization measurements to deter-mine relative susceptibility to localized corrosion (pitting andcrevice corrosion) for iron-, nickel-, or cobalt-based alloys in achloride environment. This test method also describes anexperimental procedure which can be used
4、 to check onesexperimental technique and instrumentation.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresp
5、onsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterG3 Practice for ConventionsApplicable to Electrochemi
6、calMeasurements in Corrosion TestingG5 Reference Test Method for Making Potentiostatic andPotentiodynamic Anodic Polarization Measurements2.2 ASTM Adjuncts:Standard Samples (set of two)33. Significance and Use3.1 An indication of the susceptibility to initiation of local-ized corrosion in this test
7、method is given by the potential atwhich the anodic current increases rapidly. The more noble thispotential, obtained at a fixed scan rate in this test, the lesssusceptible is the alloy to initiation of localized corrosion. Theresults of this test are not intended to correlate in a quantitativemanne
8、r with the rate of propagation that one might observe inservice when localized corrosion occurs.3.2 In general, once initiated, localized corrosion can propa-gate at some potential more electropositive than that at whichthe hysteresis loop is completed. In this test method, thepotential at which the
9、 hysteresis loop is completed is deter-mined at a fixed scan rate. In these cases, the more electrop-ositive the potential at which the hysteresis loop is completedthe less likely it is that localized corrosion will occur.3.3 If followed, this test method will provide cyclic poten-tiodynamic anodic
10、polarization measurements that will repro-duce data developed at other times in other laboratories usingthis test method for the two specified alloys discussed in 3.4.The procedure is used for iron-, nickel-, or cobalt-based alloysin a chloride environment.3.4 A standard potentiodynamic polarization
11、 plot is in-cluded. These reference data are based on the results from fivedifferent laboratories that followed the standard procedure,using specific alloys of Type 304 stainless steel, UNS S30400and Alloy C-276, UNS N10276.3Curves are included whichhave been constructed using statistical analysis t
12、o indicate theacceptable range of polarization curves.3.5 The availability of a standard test method, standardmaterial, and standard plots should make it easy for aninvestigator to check his techniques to evaluate susceptibilityto localized corrosion.4. Apparatus4.1 The polarization cell should be s
13、imilar to the onedescribed in Reference Test Method G5. Other polarizationcells may be equally suitable.4.1.1 The cell should have a capacity of about 1 L andshould have suitable necks or seals to permit the introductionof electrodes, gas inlet and outlet tubes, and a thermometer.The Luggin probe-sa
14、lt bridge separates the bulk solution fromthe saturated calomel reference electrode. The probe tip shouldbe adjustable so that it can be brought into close proximity withthe working electrode.1This test method is under the jurisdiction of ASTM Committee G01 onCorrosion of Metals and is the direct re
15、sponsibility of Subcommittee G01.11 onElectrochemical Measurements in Corrosion Testing.Current edition approved May 1, 2009. Published May 2009. Originallyapproved in 1986. Last previous edition approved in 2003 as G 6186(2003)1.2For referenced ASTM standards, visit the ASTM website, www.astm.org,
16、orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from ASTM International Headquarters. Order Adjunct No.ADJG0061. Original adjunct produced before 1995.1Copyright ASTM I
17、nternational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2 Specimen Holder:4.2.1 Specimens should be mounted in a suitable holderdesigned for flat strip, exposing 1 cm2to the test solution (Fig.1). Such specimen holders have been described in the litera-tur
18、e.4It is important that the circular TFE-fluorocarbon gasketbe drilled and machined flat in order to minimize crevices.4.3 Potentiostat (Note 1)A potentiostat that will maintainan electrode potential within 1 mV of a preset value over awide range of applied currents should be used. For the type ands
19、ize of standard specimen supplied, the potentiostat shouldhave a potential range of 1.0 to +1.6 V and an anodic currentoutput range of 1.0 to 105A. Most commercial potentiostatsmeet the specific requirements for these types of measure-ments.NOTE 1These instrumental requirements are based upon values
20、 typi-cal of the instruments in the five laboratories that have provided the dataused in determining the standard polarization plot.4.4 Potential-Measuring Instruments (Note 1)Thepotential-measuring circuit should have a high input imped-ance on the order of 1011to 1014V to minimize current drawnfro
21、m the system during measurements. Instruments shouldhave sufficient sensitivity and accuracy to detect a change inpotential of 61 mV, usually included in commercial poten-tiostats. An output as a voltage is preferred for recordingpurposes.4.5 Current-Measuring Instruments (Note 1)An instru-ment that
22、 is capable of measuring a current accurately to within1 % of the absolute value over a current range between 1.0 and105Ashould be used. Many commercial units have a build-ininstrument with an output as a voltage, which is preferred forrecording purposes. For the purpose of the present test alogarit
23、hmic output is desirable.4.6 Anodic Polarization CircuitAscanning potentiostat isused for potentiodynamic measurements. Potential and currentare plotted continuously using an X-Y recorder and a logarith-mic converter (contained in the potentiostat or incorporatedinto the circuit) for the current. Co
24、mmercially available unitsare suitable.4.7 Electrodes:4.7.1 The standard Type 304 stainless steel (UNS S30400)and Alloy C-276 (UNS N10276) should be machined into flat0.625-in. (14-mm) diameter disks. The chemical compositionsof the alloys used in the round robin are listed in Table 1.4.7.2 Counter
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMG6119862009STANDARDTESTMETHODFORCONDUCTINGCYCLICPOTENTIODYNAMICPOLARIZATIONMEASUREMENTSFORLOCALIZEDCORROSIONSUSCEPTIBILITYOFIRONNICKELORCOBALTBASEDALLPDF

链接地址:http://www.mydoc123.com/p-540671.html