ASTM G51-1995(2012) Standard Test Method for Measuring pH of Soil for Use in Corrosion Testing《测量腐蚀试验用土壤pH值的标准试验方法》.pdf
《ASTM G51-1995(2012) Standard Test Method for Measuring pH of Soil for Use in Corrosion Testing《测量腐蚀试验用土壤pH值的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM G51-1995(2012) Standard Test Method for Measuring pH of Soil for Use in Corrosion Testing《测量腐蚀试验用土壤pH值的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: G51 95 (Reapproved 2012)Standard Test Method forMeasuring pH of Soil for Use in Corrosion Testing1This standard is issued under the fixed designation G51; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a procedure for determining thepH of a soil in corrosion testing. The principle use of the testis
3、 to supplement soil resistivity measurements and therebyidentify conditions under which the corrosion of metals in soilmay be accentuated (see G5778(1984).1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard doe
4、s not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Stan
5、dards:2E177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodG57 Test Method for Field Measurement of Soil ResistivityUsing the Wenner Four-Electrode Method3. Significance and Use3.1 In
6、formation on pH of soil is used as an aid in evaluatingthe corrosivity of a soil environment. Some metals are moresensitive to the pH of their environment than others, andinformation on the stability of a metal as a function of pH andpotential is available in the literature.34. Apparatus4.1 pH Meter
7、sA portable, battery-powered pH meter isnecessary for field measurements. Most instruments can alsofunction as a high-impedance voltmeter. An LCD display ispreferred for its readability in a bright, outdoor environment.4.2 Calomel and Glass Electrodes:4.2.1 Use a saturated calomel reference electrod
8、e or itsequivalent in the pH determination. A few crystals of solidpotassium chloride should always be present within the cham-ber surrounding the calomel to assure that the solution issaturated under the conditions of use. The design of theelectrode must permit the formation of a fresh liquid junct
9、ionbetween the solution of potassium chloride and the buffer ortest soil for each test and allow traces of soil to be readilyremoved by washing.4.2.2 A glass electrode of rugged construction is required.The performance of the glass electrode is satisfactory if itfurnishes the correct pH value (60.1
10、pH unit) for standardbuffered solutions.4.2.3 A combination electrode consisting of a saturatedcalomel reference electrode and a glass electrode (4.2.1 and4.2.2) combined as a single electrode is acceptable. However,the requirements outlined above are equally applicable to theelectrodes used in this
11、 combination unit.4.3 Subsurface ProbeWhen pH measurements below thesurface of the soil are required, it is necessary to use a probe ofsuitable length which will allow measurements to be made atthe depth of interest. This probe consists of a glass electrode ora combination electrode in a rubber hous
12、ing at the end of aplastic tube. One type of probe is illustrated in Fig. 1.4.4 Soil ThermometerSome pH electrodes have tempera-ture compensation built in as part of the pH electrode, but mostdo not (see manufacturers specifications). A thermometer ofrugged construction is required for soil use, and
13、 a stainlesssteel sheathed thermometer is preferred. Metal sheathed ther-mometers come in different lengths, and a length appropriatefor the depth of interest should be chosen.1This test method is under the jurisdiction of ASTM Committee G01 onCorrosion of Metals and is the direct responsibility of
14、Subcommittee G01.10 onCorrosion in Soils.Current edition approved May 1, 2012. Published June 2012. Originallyapproved in 1977. Last previous edition approved in 2005 as G5195(2005). DOI:10.1520/G0051-95R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer
15、 Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Pourbaix, M., Atlas of Electrochemical Equilibria in Aqueous Solutions,Pergamon Press, 1966.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box
16、C700, West Conshohocken, PA 19428-2959, United States.5. Reagents and Materials5.1 During the calibration procedure for the pH meter,standard buffered solutions of known pH are necessary. Thesesolutions, or tablets to make up these solutions, can bepurchased from chemical supply companies or pH equi
17、pmentmanufacturers.6. Sampling6.1 By the nature of the measurement, pH is determined fora small volume of soil at each reading, and it is important thatat least three measurements at different locations be made anda simple average calculated. The regions of interest, surface,subsurface, or both, whe
18、re applicable, must be sampled.7. Calibration and Standardization7.1 Test for LinearityPrior to field use, or periodicallywhen used extensively in the field, test the apparatus forlinearity of response. This procedure is as follows:7.1.1 Turn on the instrument, allow to warm up thoroughly,and bring
19、to electrical balance in accordance with the manu-facturers instructions. Before use, clean and rinse the glass andcalomel electrodes in distilled water.47.1.2 At least two standard buffered pH solutions that spanthe soil pH to be measured are required. From practicalexperience standard solutions of
20、 pH 4, 7, and 8 are recom-mended. For the test, the temperature of these solutions shallnot differ from each other by more than 5C. A laboratorythermometer can be used for these measurements.7.1.3 Adjust the temperature compensating dial on the pHmeter to the standard solution temperature.7.1.4 Imme
21、rse the electrodes in a small volume of the firstknown standard solution. Now adjust the pH meter to read thisknown pH.7.1.5 Remove the electrodes from the first standard solution,and rinse in distilled water. Immerse the electrodes in thesecond known standard solution and read the pH value. Judgeth
22、e system to be operating satisfactorily if the reading obtainedfor the second standard agrees within 60.1 unit of the assignedpH.7.2 Calibration of pH MeterCalibrate the pH meter im-mediately before use. If a series of measurements are to bemade, repeat the calibration procedure at intervals of abou
23、t 30min. Perform the pH meter calibration as follows:7.2.1 Use a standard pH solution in the range of the pH ofthe soil to be tested, if such information is known beforehand.Otherwise, begin with a standard solution having a pH of 7.Stabilize the temperature of the solution so that it matches thetem
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMG5119952012STANDARDTESTMETHODFORMEASURINGPHOFSOILFORUSEINCORROSIONTESTING 测量 腐蚀 试验 土壤 PH 标准 方法 PDF

链接地址:http://www.mydoc123.com/p-540650.html