《ASTM F3150-2015 Standard Specification for HEPA Filtration System Performance of Residential and Commercial Vacuum Cleaners《住宅和商业真空清洁剂的HEPA过滤系统性能的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM F3150-2015 Standard Specification for HEPA Filtration System Performance of Residential and Commercial Vacuum Cleaners《住宅和商业真空清洁剂的HEPA过滤系统性能的标准规格》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F3150 15Standard Specification forHEPA Filtration System Performance of Residential andCommercial Vacuum Cleaners1This standard is issued under the fixed designation F3150; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification defines industry acceptable test meth-ods and approaches for evaluating residential
3、and commercialvacuum cleaner filtration systems to HEPA filtration perfor-mance levels.1.2 This specification defines the minimum filtration effi-ciency requirements for achieving HEPA performance forfiltration systems of residential and commercial vacuum clean-ers.1.3 This specification applies onl
4、y to residential and com-mercial vacuum cleaning products that are used in non-criticalapplications. Non-critical applications refers to applicationsnot requiring the removal of hazardous dust as defined per IEC60335-2-69.1.4 This standard does not purport to address all of thesafety concerns, if an
5、y, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F1977 Test Method for Determining Initial, Fractio
6、nal, Fil-tration Efficiency of a Vacuum Cleaner SystemF2608 Test Method for Determining the Change in RoomAir Particulate Counts as a Result of the Vacuum CleaningProcessF395 Terminology Relating to Vacuum Cleaners2.2 European Standards:3EN 18225 High Efficiency Air Filters (EPA, HEPA, andULPA) Part
7、 5: Determining the Efficiency of FilterElements2.3 IEST Standards:4IEST-RP-CC0001.5 HEPA and ULPA filtersIEST-RP-CC0007.2 Testing ULPA FiltersIEST-RP-CC0034 HEPA and ULPA Filter Leak Tests2.4 IEC Standard:5IEC 60335269, Edition 4.0 Particular Requirements forWet and Dry Vacuum Cleaners for Commerci
8、al use,Clause 3.1043. Terminology3.1 Definitions:3.1.1 commercial vacuum cleanera vacuum cleaner suit-able for the heavy duty and sometimes continuous cleaningtasks encountered in establishments such as hotels, motels,office buildings, churches, clubs, etc.3.1.2 filtration systemrefers to the filtra
9、tion efficiencyperformance of the vacuum cleaners dust capturing systemminus any motor emissions. Motor emissions are not includedin determining filtration system efficiency performance sincemotor emissions are generated independently of the cleaningprocess and are not a part of the dust and debris
10、being removedfrom the floor surface. Motor emissions are addressed underTest Method F2608.3.1.3 HEPA (High Effciency Particulate Air)refers to alevel of filtration performance in terms of particulate efficien-cies.3.1.4 residential vacuum cleanera vacuum cleaner suit-able for the normal cleaning tas
11、ks encountered in residencesand family households, in contrast to a commercial vacuumcleaner.4. Sampling4.1 A minimum of three units of the same model vacuumcleaner selected at random in accordance with good statisticalpractice shall constitute the population sample.1This specification is under the
12、jurisdiction of ASTM Committee F11 onVacuum Cleaners and is the direct responsibility of Subcommittee F11.23 onFiltration.Current edition approved Nov. 1, 2015. Published November 2015. DOI:10.1520/F3150-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer
13、 Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from British Standards Institution (BSI), 389 Chiswick High Rd.,London W4 4AL, U.K., http:/.4Available from Institute of Environmental Sciences
14、 and Technology (IEST),Arlington Place One, 2340 S. Arlington Heights Rd., Suite 100, Arlington Heights,IL 60005-4516, http:/www.iest.org.5Available from International Electrotechnical Commission (IEC), 3, rue deVaremb, P.O. Box 131, CH-1211 Geneva 20, Switzerland, http:/www.iec.ch.Copyright ASTM In
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF31502015STANDARDSPECIFICATIONFORHEPAFILTRATIONSYSTEMPERFORMANCEOFRESIDENTIALANDCOMMERCIALVACUUMCLEANERS

链接地址:http://www.mydoc123.com/p-540089.html