《ASTM F3139-2015 Standard Test Method for Analysis of Tin-Based Solder Alloys for Minor and Trace Elements Using Inductively Coupled Plasma Atomic Emission Spectrometry《采用感应耦合等离子体发射.pdf》由会员分享,可在线阅读,更多相关《ASTM F3139-2015 Standard Test Method for Analysis of Tin-Based Solder Alloys for Minor and Trace Elements Using Inductively Coupled Plasma Atomic Emission Spectrometry《采用感应耦合等离子体发射.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F3139 15Standard Test Method forAnalysis of Tin-Based Solder Alloys for Minor and TraceElements Using Inductively Coupled Plasma AtomicEmission Spectrometry1This standard is issued under the fixed designation F3139; the number immediately following the designation indicates the year ofo
2、riginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers procedures for the analysis oftin-ba
3、sed solder alloys for minor and trace elements usinginductively-coupled plasma atomic emission spectrometry(ICP-AES) instrumentation.1.2 These test procedures were validated for the analytesand mass fractions listed below.Element Validated Mass FractionRange, mg/kgLead 115 to 965Cadmium 25 to 60Merc
4、ury 5 to 530Antimony 85 to 1330Bismuth 80 to 210Arsenic 95 to 360Silver 4000 to 42100Cobalt 0.5 to 60Iron 15to115Chromium 0.5 to 1.5Copper 3000 to 30600Indium 25 to 115Nickel 5 to 150Phosphorus 10 to 110Selenium 1 to 30Zinc 2 to 160Aluminum 1 to 31.3 The procedures appear in the following order:Proc
5、edure SectionInternal Standardization 8Calibration Solution Preparations 9Preparation of Sample and Validation Solutions 10Calibration 11Analysis Procedure 121.4 The values stated in SI units are to be regarded as thestandard. Any other values are for information only.1.5 This standard does not purp
6、ort to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D11
7、29 Terminology Relating to WaterE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE416 Practice for Planning and Safe Operation of a Spec-trochemical Laboratory (Withdrawn 2005)3E691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE14
8、79 Practice for Describing and Specifying Inductively-Coupled Plasma Atomic Emission Spectrometers3. Terminology3.1 DefinitionsFor definitions of other terms used in thistest method, refer to Terminology D1129.3.2 Acronyms:3.2.1 ACS, nAmerican Chemical Society3.2.2 ICP-AES, ninductively-coupled plas
9、ma atomicemission spectrometry3.2.3 PE, npolyethylene3.2.4 SI, nLe Systme International dUnits, Interna-tional System of Units3.3 Definitions of Terms Specific to This Standard:3.3.1 calibration blank, na volume of water containingthe same acid matrix as found in the calibration standards.3.3.2 cali
10、bration standards, na series of known standardsolutions used to calibrate an instrument.3.3.3 check standard, nstandard used to verify properinstrument calibration.1This test method is under the jurisdiction of ASTM Committee F40 onDeclarable Substances in Materials and is the direct responsibility
11、of SubcommitteeF40.01 on Test Methods.Current edition approved May 1, 2015. Published July 2015. DOI: 10.1520/F3139-152For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer t
12、o the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.3.4 instrument linear range, nrange where i
13、nstrumentresponse and accuracy remain within typically 5 to 10 % ofknown values.3.3.5 internal standard, npure element(s) added in knownamount(s) to a solution to be used to improve instrumentaccuracy.3.3.6 reference material solution, nsolution standard withknown certified mass fraction(s), typical
14、ly commercially avail-able.3.3.7 sample introduction system, nplasma torch, mixingchamber and nebulizer used to deliver solutions to the plasmafor analysis.3.3.8 validation sample, na solder alloy sample that hasbeen certified or well characterized for mass fractions ofanalytes present, and can be u
15、sed to validate the method.4. Significance and Use4.1 Tin-based solder alloys are commonly used to manufac-ture electrical and electronic goods. The elements lead,cadmium, mercury, antimony and bismuth are often declarablesubstances in solder materials. This test method provides ameans of determinin
16、g the listed declarable substances, as wellas other minor and trace constituents, in tin-based solder alloys.4.2 Two methods of dissolving tin-based solder alloys aregiven in this standard. The first method uses open-vesselhydrofluoric and nitric acid room temperature digestions; thesecond method em
17、ploys closed-vessel nitric and hydrofluoricacid microwave digestions, both for use only with ICP-AESinstruments equipped with a hydrofluoric acid resistant sampleintroduction system.4.3 The method of preparing calibration solutions uses 1000mg/kg single element reference material solutions, and uses
18、matching concentrated acids for both the calibration solutionsand the sample solutions.4.4 This test method is intended for use by laboratoriesexperienced with the set-up, calibration and analysis ofsamples using ICP-AES.5. Reagents5.1 Purity of ReagentsReagent grade chemicals, at aminimum, shall be
19、 used in all tests. Unless otherwise indicated,all reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.4Other grades equiva-lent or better than the ACS grade reagents may also be used.5.2 Purit
20、y of WaterUnless otherwise indicated, referencesto water shall be understood to mean high purity water, thatwhen produced, measures at minimum 18 Megohm cm-1resistivity.5.3 Concentrated AcidsWhen acids are specified by nameor chemical formula only, it should be understood that concen-trated reagents
21、 of the following mass fractions are intended:Concentrated AcidNominal MassFractionHydrofluoric acid, HF 48 %Nitric acid, HNO369 %5.4 Single Element Reference Material SolutionsAllsingle element solutions used in this method must haveassigned mass fraction values in mg/kg units as opposed tomg/L uni
22、ts. It is possible to derive mg/kg values from mg/Lassigned values through determination of standard solutiondensity and subsequent calculation of mg/kg unit values.5.4.1 The method of preparing calibration solutions uses1000 mg/kg single element reference material solutions of Pb,Cd, Hg, Sb, Bi, As
23、, Ag, Co, Fe, Cr, Cu, In, Ni, P, Se, Zn, Al,Ge, and Tl. A single element reference material solution of Scat 1000 mg/kg is required for use as an internal standard.5.4.2 It is not important that the assigned value of thereference material solutions be exactly 1000 mg/kg; forexample, the assigned val
24、ue may be 1001 mg/kg or 997 mg/kg.6. Equipment6.1 Inductively Coupled Plasma-Atomic Emission Spec-trometry System (ICP-AES)Many makes and models ofICP-AES instruments are available on the market. See PracticeE1479 for a general description of ICP-AES instrumentation.The specific instrumentation used
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF31392015STANDARDTESTMETHODFORANALYSISOFTINBASEDSOLDERALLOYSFORMINORANDTRACEELEMENTSUSINGINDUCTIVELYCOUPLEDPLASMAATOMICEMISSIONSPECTROMETRY

链接地址:http://www.mydoc123.com/p-540076.html