ASTM F2977-2013 Standard Test Method for Small Punch Testing of Polymeric Biomaterials Used in Surgical Implants《外科植入物用高分子生物材料的小型冲孔测试的标准试验方法》.pdf
《ASTM F2977-2013 Standard Test Method for Small Punch Testing of Polymeric Biomaterials Used in Surgical Implants《外科植入物用高分子生物材料的小型冲孔测试的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2977-2013 Standard Test Method for Small Punch Testing of Polymeric Biomaterials Used in Surgical Implants《外科植入物用高分子生物材料的小型冲孔测试的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2977 13Standard Test Method forSmall Punch Testing of Polymeric Biomaterials Used inSurgical Implants1This standard is issued under the fixed designation F2977; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of mechanicalbehavior of polymeric biomaterials by small punch testing o
3、fminiature disk specimens (0.5 mm in thickness and 6.4 mm indiameter). The test method has been established for character-izing surgical materials after ram extrusion or compressionmolding (1-3)2; for evaluating as-manufactured implants andsterilization method effects (4, 5); as well as for testing
4、ofimplants that have been retrieved (explanted) from the humanbody (6, 7).1.2 The results of the small punch test, namely the peakload, ultimate displacement, ultimate load, and work to failure,provide metrics of the yielding, ultimate strength, ductility, andtoughness under multiaxial loading condi
5、tions. Because themechanical behavior can be different when loaded underuniaxial and multiaxial loading conditions (8), the small punchtest provides a complementary mechanical testing technique tothe uniaxial tensile test. However, it should be noted that thesmall punch test results may not correlat
6、e with uniaxial tensiletest results.1.3 In addition to its use as a research tool in implantretrieval analysis, the small punch test can be used as alaboratory screening test to evaluate new materials withminimal material waste (1).1.4 The small punch test has been applied to other polymers,includin
7、g polymethyl methacrylate (PMMA) bone cement,polyacetal, and high density polyethylene (HDPE), ultra highmolecular weight polyethylene (UHMWPE), and polyethere-therketone (PEEK) (2, 3, 5, 10, 11). This standard outlinesgeneral guidelines for the small punch testing of implantablepolymers.1.5 This st
8、andard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1
9、 ASTM Standards:3D695 Test Method for Compressive Properties of RigidPlasticsD883 Terminology Relating to PlasticsE4 Practices for Force Verification of Testing MachinesE83 Practice for Verification and Classification of Exten-someter SystemsF1714 Guide for Gravimetric WearAssessment of ProstheticHi
10、p Designs in Simulator DevicesF1715 Guide for Wear Assessment of Prosthetic Knee De-signs in Simulator Devices (Withdrawn 2006)4F2003 Practice for Accelerated Aging of Ultra-High Mo-lecular Weight Polyethylene after Gamma Irradiation inAirF2102 Guide for Evaluating the Extent of Oxidation inUltra-Hi
11、gh-Molecular-Weight Polyethylene FabricatedForms Intended for Surgical Implants3. Terminology3.1 Definitions:3.1.1 small punch test, na test wherein the specimen is ofminiature size relative to conventional mechanical testspecimens, is disk-shaped, and is loaded axisymmetrically inbending by a hemis
12、pherical-head punch.NOTE 1The features of a typical small punch test load versusdisplacement curve for PEEK, UHMWPE, and PMMA bone cement areillustrated in Fig. 1(a-c) and Fig. 2.3.2 Definitions of Terms Specific to This Standard:3.2.1 peak load, nan initial local maximum in the loadversus displacem
13、ent curve (Fig. 2). In certain polymer formu-lations such as radiation crosslinked UHMWPE materials, theload versus displacement curve increases monotonically and a1This test method is under the jurisdiction of ASTM Committee F04 on Medicaland Surgical Materials and Devices and is the direct respons
14、ibility of SubcommitteeF04.15 on Material Test Methods.Current edition approved June 1, 2013. Published August 2013. DOI: 10.1520/F2977-13.2The boldface numbers in parentheses refer to the list of references at the end ofthis standard.3For referenced ASTM standards, visit the ASTM website, www.astm.
15、org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Har
16、bor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1shoulder, rather than an initial peak load, may be observed. Forbrittle materials, the load versus displacement behavior may becompletely linear, in which case no peak load would beobserved.3.2.2 ultimate load, nthe load at rupt
17、ure (failure) of thespecimen that is calculated at the first point before the breakingpoint in the curve where the root of the first derivative is equalto zero (Fig. 2).3.2.3 ultimate displacement, nthe displacement at rupture(failure) of the specimen (Fig. 2).3.2.4 work to failure, nthe area under
18、the load versusdisplacement curve (Fig. 2).4. Significance and Use4.1 Miniature specimen testing techniques are used to char-acterize the mechanical behavior of polymer stock materialsand surgical implants after manufacture, sterilization, shelfaging, radiation crosslinking, thermal treatment, fille
19、rincorporation, and implantation (1-3). Furthermore, experi-mental materials can be evaluated after accelerated aging,fatigue testing, and hip, knee, or spine wear simulation.Consequently, the small punch test makes it possible toexamine relationships between wear performance and me-chanical behavio
20、r. This test method can also be used to rank themechanical behavior relative to a reference control material.4.2 Small punch testing results may vary with specimenpreparation and with the speed and environment of testing.Consequently, where precise comparative results are desired,these factors must
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF29772013STANDARDTESTMETHODFORSMALLPUNCHTESTINGOFPOLYMERICBIOMATERIALSUSEDINSURGICALIMPLANTS 外科 植入

链接地址:http://www.mydoc123.com/p-539847.html