1、Designation: F 2771 09Standard Test Method forDetermining the Luminance Curve of an ElectroluminescentLamp at Ambient Conditions1This standard is issued under the fixed designation F 2771; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method establishes the procedures for deter-mining the visible performance change, which i
3、s defined byluminance, color and cosmetic appearance of an electrolumi-nescent lamp during operation over an extended time.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro
4、-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F 1595 Practice for Viewing Conditions for Visual Inspec-tion of Membrane SwitchesF 2359 Test Method for Determining Color of a MembraneSwitch Backli
5、t with Diffuse Light SourceF 2360 Test Method for Determining Luminance of a Mem-brane Switch Backlit with Diffuse Light Source3. Terminology3.1 Definitions:3.1.1 luminance, nmeasure of the brightness or luminousintensity of light, usually expressed in units of candelas persquare metre (cd/m2) or fo
6、ot lamberts. 1 fL = 3.426 cd/m2.3.1.2 luminance curve, na graphical representation of thevariation of luminance with time (implicitly under unvaryingoperating conditions).3.1.3 electroluminescent lamp (EL lamp), nessentially acapacitor structure with phosphor and a dielectric sandwichedbetween elect
7、rodes, one of which is transparent to allow lightto escape. Application of an ac voltage across the electrodesgenerates a charging field within the phosphor, which causes itto emit light.3.1.4 time to half luminance (THL), nthe elapsed operat-ing time over which the luminance of a lamp maintained un
8、derconstant power conditions is reduced to 50 % of its initialvalue.3.1.5 membrane switch, na momentary switching device,in which at least one contact is on, or made of, a flexiblesubstrate.4. Summary of Test Method4.1 This test method includes an initial measurement of theluminance, color, and appe
9、arance of a lamp when poweredwith a specified voltage source. After initial characterization,the lamp is maintained under the same power conditions for anextended interval in a controlled environment designed tointerfere minimally with the operating characteristics of thelamp. The luminance, color a
10、nd appearance of the lamps undertest are measured and recorded at a predetermined schedulethroughout the test (initially the intervals are shorter to capturethe rapid rate of change and longer as the test progresses). Oneoutput of the measurement is to identify the time of operationby which the meas
11、ured luminance is reduced to half thatrecorded at the initial characterization.5. Significance and Use5.1 To provide a standardized test method that can be usedfor a valid comparison of luminance time curves, color changesand cosmetic changes between lamps of various designs,fabrication techniques,
12、and sources.6. Interferences6.1 HumidityPerformance characteristics can be skewedwith the change of humidity.6.2 TemperaturePerformance characteristics can beskewed with the change of temperature.6.3 PowerPerformance characteristics can be skewedwith variations in the voltage, frequency and waveform
13、 of thepower applied to the lamp.1This test method is under the jurisdiction of ASTM Committee F01 onElectronics and is the direct responsibility of Subcommittee F01.18 on MembraneSwitches.Current edition approved May 1, 2009. Published June 2009.2For referenced ASTM standards, visit the ASTM websit
14、e, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States
15、.7. Apparatus7.1 Power source capable of providing an appropriate acvoltage and frequency. For example, operation at 110 6 3VRMS, at 400 6 10 Hz, which is prevalent in the industry.Anydeviation shall be reported.7.2 Luminance measurement equipment as specified in TestMethod F 2360.7.3 Color measurem
16、ent equipment as specified in TestMethod F 2359.8. Hazards8.1 8.1 The procedure requires the verification of highvoltage ac power. Proper precautions against personal hazardsshould be followed.9. Preparation of Apparatus9.1 A location should be established in which the lamp canremain while powered f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF27712009STANDARDTESTMETHODFORDETERMININGTHELUMINANCECURVEOFANELECTROLUMINESCENTLAMPATAMBIENTCONDITIONSPDF

链接地址:http://www.mydoc123.com/p-539430.html