ASTM F2428-2004 Standard Guide for Selection and Use for Pelvic Ring Circumferential Compression Stabilization Devices (PRCCSD)《骨盆环状面压缩稳定设备的选择和使用的标准指南》.pdf
《ASTM F2428-2004 Standard Guide for Selection and Use for Pelvic Ring Circumferential Compression Stabilization Devices (PRCCSD)《骨盆环状面压缩稳定设备的选择和使用的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2428-2004 Standard Guide for Selection and Use for Pelvic Ring Circumferential Compression Stabilization Devices (PRCCSD)《骨盆环状面压缩稳定设备的选择和使用的标准指南》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2428 04Standard Guide forSelection and Use for Pelvic Ring CircumferentialCompression Stabilization Devices (PRCCSD)1This standard is issued under the fixed designation F 2428; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide establishes minimum standards for devicesdesignated here as pelvic ring circumferenti
3、al compressionstabilization devices(s) (PRCCSD), commonly known as pel-vic slings, belts, or binders. The PRCCSD is used as the initialpelvic ring stabilization device on patients suspected of havingsustained traumatic disruptions of the pelvic ring. It is usedduring patient transport by emergency p
4、ersonnel and beforedefinitive treatment.1.2 This guide addresses the recognized need to reduce andstabilize pelvic ring disruptions through the use of circumfer-ential compression devices.1.3 Peer-reviewed medical literature does describe specifictesting methods used to determine the range of effect
5、ivecompression force, efficacy in reduction, stability, and safetyfor a particular (PRCCSD). This guide, however, does notidentify specific testing methods as it is recognized suchmethods could vary according to device configuration andstudy design.1.4 This guide does not address individual quantita
6、tiveperformance standards for any particular device, but doesaddress general performance standards and good practicecharacteristics for all devices using circumferential compres-sion to reduce and stabilize disruptions of the pelvic ring.1.5 This standard does not purport to address all of thesafety
7、 concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to use.2. Terminology2.1 Definitions:2.1.1 circumferential compression force, ninfl
8、uence thatdeforms an object by shortening its circumference.2.1.2 compression force, ninfluence that deforms an ob-ject by making it smaller or shorter.2.1.3 controlled level of force, nforce confined withincertain defined limits.2.1.4 disruption of the pelvic ring, nany traumatic alter-ation of the
9、 normal anatomic relationships of the bony struc-tures forming the pelvic ring. Included in these disruptions arefractures, dislocations, subluxation, and diastasis.2.1.5 effective level of force, nthat range of quantifiedforce required by the particular pelvic ring circumferentialcompression stabil
10、ization device (PRCCSD) to reduce andstabilize disruptions of the pelvic ring in the 95thpercentile ofadult American males.22.1.6 immobilization, nlimitation of motion.2.1.7 pelvic ring, nnormal anatomic ring-shaped structureformed by three bones: two innominate bones (each made up ofthe ilium, isch
11、ium, and pubis) and the sacrum.2.1.8 reduction, nreturning anatomic structures to theirnormal anatomic position.2.1.9 retention system, nan adjunct to or an integral partof the primary platform that allows the patient to be securelyattached to that platform, used in whatever configuration andsize ne
12、cessary to accomplish the goal, while still allowingreasonable and necessary access to the patient.2.1.10 safe level of circumferential compression force,nthat range of quantified force producing a resultant effect inwhich no undue alteration of the normal anatomic relationshipof the pelvic ring occ
13、urs.2.1.11 stabilize, vmaintaining in a firm, constant, or fixedstate.2.1.12 spinal immobilization system, ndevice(s) that im-mobilize the spine and contiguous structures, the pelvis, andthe skull.3. Significance and Use3.1 The intent of this guide is to identify the generalperformance and good prac
14、tice standards that a pelvic ringcircumferential compression stabilization device (PRCCSD)should possess.3.2 Currently, a number of base platforms such as full-bodyspinal immobilization devices (long boards) are used to immo-bilize patients during transport and before definitive treatment.These plat
15、forms limit gross movements of the spine and pelvis1This guide is under the jurisdiction of ASTM Committee F30 on EmergencyMedical Services and is the direct responsibility of Subcommittee F30.01 on EMSEquipment.Current edition approved Oct. 1, 2004. Published October 2004.2The Handbook of Adult Ant
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF24282004STANDARDGUIDEFORSELECTIONANDUSEFORPELVICRINGCIRCUMFERENTIALCOMPRESSIONSTABILIZATIONDEVICESPRCCSD

链接地址:http://www.mydoc123.com/p-538679.html