ASTM F2324-2003(2009) Standard Test Method for Prerinse Spray Valves《预清洗喷雾器阀用标准试验方法》.pdf
《ASTM F2324-2003(2009) Standard Test Method for Prerinse Spray Valves《预清洗喷雾器阀用标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2324-2003(2009) Standard Test Method for Prerinse Spray Valves《预清洗喷雾器阀用标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2324 03 (Reapproved 2009)An American National StandardStandard Test Method forPrerinse Spray Valves1This standard is issued under the fixed designation F 2324; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the water consumption flow rateand cleanability of prerinse spray valves (here after refer
3、red toas spray valves). The food service operator can use thisevaluation to select a spray valve and understand its waterconsumption and cleaning effectiveness.1.2 The following procedures are included in this testmethod:1.2.1 Water consumption (see 10.2).1.2.2 Cleanability (see 10.3).1.3 The values
4、 stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This test method may involve hazardous materials,operations, and equipment. It does not address
5、 all of thepotential safety problems associated with its use. It is theresponsibility of the users of this test method to establishappropriate safety and health practices and determine theapplicability of regulatory limitations prior to its use.2. Referenced Documents2.1 NSF Documents:2NSF Listings
6、Food Equipment and Related Products, Com-ponents and Materials, NSF International3. Terminology3.1 Definitions:3.1.1 cleanabilitythe effectiveness of the prerinse sprayvalve to remove soil from the plate before it is placed in adishwashing machine.3.1.2 test methoda definitive procedure for the iden
7、tifica-tion, measurement, and evaluation of one or more qualities,characteristics, or properties of a material, product, system, orservice that produces a test result.3.1.3 uncertaintymeasure of systematic and precision er-rors in specified instrumentation or measure of repeatability ofa reported te
8、st result.3.2 Abbreviations:3.2.1 gpmgallons per minute.4. Summary of Test Method4.1 The flow rate of the spray valve is determined at themanufacturers specified water pressure to verify that the sprayvalve is operating at the manufacturers rated flow rate. If themeasured rate is not within 5 % of t
9、he rated flow rate, allfurther testing ceases and the manufacturer is contacted. Themanufacturer may make appropriate changes or adjustments tothe spray valve.4.2 The spray valves water flow rate is measured at 60 6 1psi (2.9 6 0.5 kPa) settings at a temperature of 120 6 4F (496 2C).4.3 The spray va
10、lves cleanability (effectiveness) is deter-mined at 60 6 1 psi (2.9 6 0.5 kPa), with a water temperatureof 120 6 4F (49 6 2C).5. Significance and Use5.1 The flow rate test is used to confirm that the spray valveis operating at the manufacturers rated flow rate at thespecified water pressure. This te
11、st would also assist theoperator in controlling the water and sewer consumption andreduce the water heating bills.5.2 The cleanability test is used to verify the spray valveseffectiveness at cleaning the plates before they are sent into thedishwashing machine.6. Apparatus6.1 Analytical Balance Scale
12、, or equivalent, for measuringthe weight of the plates and water container. It shall have aresolution of 0.01 lb (5 g) and an uncertainty of 0.01 lb (5 g).6.2 Calibrated Exposed Junction Thermocouple Probes,with a range from 50 to 200F (10 to 93C), with a resolutionof 0.2F (0.1C) and an uncertainty
13、of 1.0F (0.5C), formeasuring water line temperatures. Calibrated K-type 24-GA1This test method is under the jurisdiction of ASTM Committee F26 on FoodService Equipment and is the direct responsibility of Subcommittee F26.06 onProductivity and Energy Protocol.Current edition approved May 1, 2009. Pub
14、lished August 2009. Originallyapproved in 2003. Last previous edition approved in 2003 as F 2324 03.2Available from NSF International, P.O. Box 130140, 789 N. Dixboro Rd., AnnArbor, MI 48113-0140.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, Uni
15、ted States.thermocouple wire with stainless steel sheath and ceramicinsulation is the recommended choice for measuring the waterline temperatures. The thermocouple probe can be fed througha compression fitting so as to submerse exposed junction in thewater lines.6.3 Carboy, or equivalent container,
16、for measuring forweight of the water during the flow rate test. A 5-gal (19-L)carboy water bottle has been found to be suitable (the carboyis the standard water bottle that is used for water coolers).NOTE 1The 5-gal (19-L) carboy container is the preferred container.With a narrow opening, the carboy
17、 captures all the water during the test athigher water pressure which can result in excess splashing.6.4 Hot Water Temperature Control Valve, to maintain andlimit mixed hot water to the spray valve during testing. It shallhave a double throttling design to control both the hot and coldwater supply t
18、o the mixed outlet. The flow characteristics of thevalve shall have a resolution temperature control of 64F(62C) combined with low pressure drop check valves in boththe hot and cold water inlets to protect against cross flow.6.5 Measuring Spoons, used to portion out one level table-spoon of tomato s
19、auce on each plate for the cleanability test.6.6 Pressure Gage, for measuring pressure of water to thespray valve. The gage shall have a resolution of 0.5 psig (3.4kPa) and a maximum uncertainty of 1 % of the measured value.6.7 Spring-Style Pre-Rinse Unit, Deck-Mounted, with a36-in. (915-mm) flex ho
20、se which will have the testing samplespray valve attach at the end of the flex hose. See Fig. 1.6.8 Stopwatch, with a 0.1-s resolution.6.9 Temperature Sensor, for measuring water temperature inthe range from 50 to 200F (10 to 93C), with a resolution of0.5F (0.3C) and an uncertainty of 61F (0.5C).7.
21、Reagents and Materials7.1 Tomato Paste, shall be 100 % pure and shall have amoisture content of 70 6 2.5 %. Stabilize paste at roomtemperature (75 6 5F (24 6 3C).7.2 Gravimetric moisture analysis shall be performed asfollows: To determine moisture content, place a 1-lb sample ofthe test food on a dr
22、y, aluminum sheet pan and place the pan ina convection drying oven at a temperature of 220 6 5F for aperiod of 24 h. Weigh the sample before it is placed in the ovenand after it is removed and determine the percent moisturecontent based on the percent weight loss of the sample. Thesample must be spr
23、ead evenly over the surface of the sheet panin order for all of the moisture to evaporate during drying andit is permissible to spread the sample on top of baking paper inorder to protect the sheet pan and simplify cleanup.7.3 Tomato Sauce, shall be comprised of tomato paste andwater. Mix 6 oz (175
24、mL) tomato paste (see 7.1) with 10 oz(295 mL) of 75 6 5F (24 6 3C) water to form the tomatosauce. Stir until mixture becomes consistent.NOTE 2Testing at the Food Service Technology Center has found thata generic store brand such as “Safewayt” brand or “Albertsonst” brandtomato paste is the preferred
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF232420032009STANDARDTESTMETHODFORPRERINSESPRAYVALVES 清洗 喷雾器 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-538392.html