ASTM F2228-2013 Standard Test Method for Non-Destructive Detection of Leaks in Packaging Which Incorporates Porous Barrier Material by CO2 Tracer Gas Method《采用二氧化碳示踪气体法对多孔防渗透材料的包装泄.pdf
《ASTM F2228-2013 Standard Test Method for Non-Destructive Detection of Leaks in Packaging Which Incorporates Porous Barrier Material by CO2 Tracer Gas Method《采用二氧化碳示踪气体法对多孔防渗透材料的包装泄.pdf》由会员分享,可在线阅读,更多相关《ASTM F2228-2013 Standard Test Method for Non-Destructive Detection of Leaks in Packaging Which Incorporates Porous Barrier Material by CO2 Tracer Gas Method《采用二氧化碳示踪气体法对多孔防渗透材料的包装泄.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2228 02 (Reapproved 2007)F2228 13Standard Test Method forNon-Destructive Detection of Leaks in Medical PackagingWhich Incorporates Porous Barrier Material by CO2 TracerGas Method1This standard is issued under the fixed designation F2228; the number immediately following the designation
2、 indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This non-destructive test method dete
3、cts leaks in non-porous rigid thermoformed trays, as well as the seal between theporous lid and the tray. The test method detects channel leaks in packages as small as 100 m (0.004 in.) diameter in the seal aswell as 50 m (0.002 in.) diameter pinholes, or equivalently sized cracks in the tray, subje
4、ct to trace gas concentration in thepackage, package design and manufacturing tolerances.NOTE 1This test method does not claim to challenge the porous (breathable) lidding material. Any defects that may exist in the porous portion ofthe package will not be detected by this test method.1.2 The values
5、 stated in SI units are to be regarded as standard units. Values in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and
6、 health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D996 Terminology of Packaging and Distribution EnvironmentsF17 Terminology Relating to Flexible Barrier PackagingF1327 Terminology Relating to Barrier Materials for Medi
7、cal Packaging (Withdrawn 2007)33. Terminology3.1 General Term DefinitionsFor definitions used in this standard, see Terminologies D996, F17, and F1327.3.2 Definitions of Terms Specific to This Standard:3.2.1 basal flowtransverse transport of trace gas across the seal due to gas flow within the plane
8、 of the porous barrier materialas well as flow between the porous barrier and the temporary gasketing. This is an expected property of the porous barrier materialand does not represent a leak. Experimentally, this flow may be thought of as noise, which will always be present, to some degree,during t
9、esting and must be accounted for.3.2.2 trace gasa compound selected solely for use to identify leakage flow.4. Summary of Test Method4.1 This test method utilizes CO2 sensing techniques in the detection of a CO2 trace gas to quantify leaks in medical packaging,which incorporates porous barrier mater
10、ial. This test method provides a qualitative (accept/reject) inspection method to evaluatepackages for pinhole, crack and channel leaks. Further information on the “Leak Test Theory” may be found in Annex A1.1 This test method is under the jurisdiction of ASTM Committee F02 on Flexible Barrier Packa
11、ging and is the direct responsibility of Subcommittee F02.40 on PackageIntegrity.Current edition approved April 1, 2007Aug. 1, 2013. Published May 2007September 2013. Originally approved in 2002. Last previous edition approved in 20022007 asF2228 02.F2228 02(2007). DOI: 10.1520/F2228-02R07.10.1520/F
12、2228-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standa
13、rd is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recomm
14、ends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Significance
15、 and Use5.1 Harmful biological or particulate contaminants may enter the package through incomplete seals or imperfections such aspinholes or cracks in the trays.5.2 After initial instrument set-up and calibration, the operations of individual tests and test results do not need operatorinterpretatio
16、n. The non-destructive nature of the test may be important when testing high value added products.5.3 Leak test results that exceed the permissible threshold setting are indicated by audible or visual signal responses, or both,or by other means.5.4 This non-destructive test method may be performed i
17、n either laboratory or production environments. This testing may beundertaken on either a 100 % or a statistical sampling basis. This test method, in single instrument use and current implementation,may not be fast enough to work on a production packaging line, but is well suited for statistical tes
18、ting as well as packagedevelopmental design work.6. Apparatus6.1 Non-destructive Trace Gas Leak Detection Apparatus ApparatusThe apparatus test fixture consists of three majorelements and is shown in Fig. 1.6.2 Sealing MembraneThe purpose of the sealing membrane is to seal off the tracer gas transmi
19、ssion, normal to the porouslid surface. However, the membrane does not completely control the transmission of tracer gas basal flow in the transversedirection.6.3 Control PackagesPackages with calibrated capillary channel leaks as well as packages with calibrated pinholes in the trayconstructed for
20、instrument calibration as well as for test procedure verification.6.4 Test FixtureApparatus, which must be designed to ensure detection of a calibrated leak.7. Preparation of Apparatus7.1 The test apparatus is to be started, warmed-up, and made ready according to the manufacturers specifications. Th
21、einstrument must be operated in an environment as described in the instruments user manual.8. Reagents and Materials8.1 CO2 Trace Gas Cylinder and Regulator A cylinder of “Commercial” or “Bone Dry” grade carbon dioxide with aminimum of 206.84 kPa (30 psi) pressure is required for calibration and tes
22、ting.FIG. 1 Schematic of Test Fixture and Test PackageF2228 1328.2 Sealing MembraneThe temporary sealing membrane must exhibit the correct pliability and tackiness in order to form agas-tight bond with the porous lidding materials during the testing process, and must release at the end of the test w
23、ithout damagingthe porous lid or the edge seal.8.3 Sealing Membrane-induced Damage During the process of membrane selection for a specific package design andconfiguration, inspect the packages for the following indications of membrane-induced damage after the membrane is removedfrom the package:8.3.
24、1 Sticky residue remaining on the porous barrier material at the end of the test cycle.8.3.2 Fibers from the porous barrier material remaining on the sealing membrane at the end of the test cycle.8.3.3 Visible changes to the texture or structure of the porous lidding material at the end of the test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF22282013STANDARDTESTMETHODFORNONDESTRUCTIVEDETECTIONOFLEAKSINPACKAGINGWHICHINCORPORATESPOROUSBARRIERMATERIALBYCO2TRACERGASMETHOD

链接地址:http://www.mydoc123.com/p-538117.html