《ASTM F505-1987(2011) Standard Practice for Comparative Evaluation of Imaging Properties of Liquid Electrostatic Toners《液体静电调色剂成像特性的比较评定标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F505-1987(2011) Standard Practice for Comparative Evaluation of Imaging Properties of Liquid Electrostatic Toners《液体静电调色剂成像特性的比较评定标准操作规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F505 87 (Reapproved 2011)Standard Practice forComparative Evaluation of Imaging Properties of LiquidElectrostatic Toners1This standard is issued under the fixed designation F505; the number immediately following the designation indicates the year of originaladoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis practice is a pragmatic test for the consumer who may or may not have access to sophisticate
3、dlaboratory equipment.1. Scope1.1 This practice guides the consumer toward preparing atest for liquid toners used in copiers, which has significance totheir specific copying needs, and suggests ways in which testprints may be made and used for each evaluation.1.2 This practice does not include those
4、 procedures neces-sary for the evaluation of nonimpact printing toners, thosetoners used in the preparation of offset masters, or otherspecialty toners.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of thi
5、s standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. See Section 7 forspecific hazards statements.2. Referenced Documents2.1 ASTM Standards:2F335 Terminology Relating to Electrostatic ImagingF360 Practice for Image
6、Evaluation of Electrostatic Busi-ness CopiesF807 Practice for Determining Resolution Capability ofOffice CopiersF875 Test Method for Evaluation of LargeArea Density andBackground on Office Copiers3. Terminology3.1 DefinitionsFor definitions of terms relating to electro-static copying, see Terminolog
7、y F335.4. Summary of Practice4.1 This practice involves the comparative evaluation of oneor more toner supplies by rating subjectively a number ofsignificant characteristics of imaged copies made under con-trolled conditions on a liquid toner electrostatic copier.5. Significance of Use5.1 Subjective
8、 comparative evaluation of copies made fromthe same test originals can be used to determine the usefulnessof a given toner supply in a specific user application.6. Interferences6.1 Many copy systems are subject to variation due tofluctuation of line voltage. It is conceivable that such fluctua-tions
9、 may cause a normally useful system to give poor results.The manufacturer of the equipment should be consultedregarding the need for voltage-stabilizing devices which canusually be installed easily.6.2 Results from a copy system can vary depending uponthe length of time the system has been operating
10、. The first printafter a system has been shut down for a prolonged time periodcan be of different quality than subsequent prints made aftersome time of operation.6.3 Variations in copy system performance after continuouscopying over relatively long periods can occur (that is, severalhours or more).
11、It is recommended that the procedure berepeated if significant variation in copy system performanceoccurs.6.4 Variations in copy system performance can occur as aresult of copier adjustments (for example, before and afterservice calls).1This practice is under the jurisdiction of ASTM Committee F05 o
12、n BusinessImaging Products and is the direct responsibility of Subcommittee F05.04 onElectrostatic Imaging Products.Current edition approved Oct. 1, 2011. Published March 2012. Originallyapproved in 1977. Last previous edition approved in 2001 as F50587 (2006). DOI:10.1520/F0505-87R06.2For reference
13、d ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Con
14、shohocken, PA 19428-2959, United States.6.5 Excessively high or low relative humidity can also causevariation in performance not encountered under normal condi-tions.6.6 All tests should be conducted in the same copier, duringthe same relative time period and environmental conditions.6.7 Toner suppl
15、ies (including both toner and diluents) areoften purchasable from several sources and can affect results ofthe given copy system.6.8 Paper supplies can be purchased from several sourcesand also can affect results of a given copy system. The usershould use only the grade and weight of paper recommend
16、edby the copier manufacturer when evaluating one or more tonersupplies. All paper supplies utilized should be from the samemanufacturing source, and the user should try to use all papersupplies from the same production number (provided one islisted). Some inherent variability within the paper may af
17、fectimage quality evaluation as will certain unintentional paperdefects. Some variability may be encountered from one roll tothe next or from one package of sheets to a second package,and sometimes within a package.6.9 Variations in toner concentration strongly affect copyquality and should be minim
18、ized to the extent made availableby the mechanics of the copy system.6.10 Toners for these systems usually have a finite shelf life.The user should carefully follow the manufacturers recom-mendations on storage conditions and length of storage.7. Technical Hazards7.1 This practice is intended to ori
19、ent the user towardobserving meaningful and significant characteristics of imagedcopies obtained from a limited number of imaged copies. Itdoes not encompass those defects of which the user should beaware such as deterioration, abrasion or scratching, or otheradverse actions that could reduce the ef
20、fectiveness of theoperation of the copier with the test toner supplies. Themanufacturer of the test toner supplies should be consultedprior to the evaluation of the supplies in order to ascertain whatlong-term functional testing (including compatability resultswith the copier and current reference t
21、oner supplies used by theuser) has been performed by the test toner supplier on theparticular model copier the user possesses. The manufacturerof the copier should also be contacted prior to any test shouldany question of consequential damages to the copier beinvolved.7.2 Many toner copier manufactu
22、rers require that onlytrained service people should be permitted access to specificinternal copier components. Prior to any testing, the manufac-turer of the copier should be consulted as to which componentsor copier areas, or both (if any), the consumer may have accessto for visual evaluation of to
23、ner build-up. It may be necessaryfor the user to require the copier manufacturers servicepersonnel to perform all necessary component clean-up.Should this step be required, the user should be present toobserve and record all observations regarding this maintenancestep.8. Sampling8.1 Sampling is not
24、applicable to this practice.9. Procedure9.1 Before beginning this practice comparison, the manu-facturers instructions on the operation of the copier must beread, understood, and followed. The toner being evaluated isbest tested in a copy system at the site of its proposedinstallation under the line
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF50519872011STANDARDPRACTICEFORCOMPARATIVEEVALUATIONOFIMAGINGPROPERTIESOFLIQUIDELECTROSTATICTONERS

链接地址:http://www.mydoc123.com/p-536801.html