ASTM F2006-2000(2005) Standard Safety Specification for Window Fall Prevention Devices for Non-Emergency Escape (Egress) and Rescue (Ingress) Windows《非紧急出口和营救窗口用窗下落防护装置的标准安全规范》.pdf
《ASTM F2006-2000(2005) Standard Safety Specification for Window Fall Prevention Devices for Non-Emergency Escape (Egress) and Rescue (Ingress) Windows《非紧急出口和营救窗口用窗下落防护装置的标准安全规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2006-2000(2005) Standard Safety Specification for Window Fall Prevention Devices for Non-Emergency Escape (Egress) and Rescue (Ingress) Windows《非紧急出口和营救窗口用窗下落防护装置的标准安全规范》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2006 00 (Reapproved 2005)Standard Safety Specification forWindow Fall Prevention Devices for Non-Emergency Escape(Egress) and Rescue (Ingress) Windows1, 2This standard is issued under the fixed designation F 2006; the number immediately following the designation indicates the year ofo
2、riginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe consumer safety specification addresses window fall pre
3、vention devices that protect againstpotential falls by children age five and under from windows not designated for emergency escape orrescue in installations more than 75 ft (23 m) above ground level in multiple family dwellingbuildings. This specification does not apply to devices applied to window
4、s installed in one and twofamily dwellings.A special study3by the U.S. Consumer Product Safety Commission indicates that young childrenare at high risk of death and serious injury from window falls. Children age five and younger accountfor a higher percentage of window fall fatalities and injuries4.
5、Window fall prevention devices usually differ in purpose and application from security/burglar bars.The general purpose of a window fall prevention device is to prevent a child age five or younger fromfalling from a window. The general purpose of a security bar is to prevent unlawful entry through a
6、window. Generally window fall prevention devices and security bars are two separate devices.However, a security bar could be used as a fall prevention device if it meets the requirements of thisspecification.1. Scope1.1 This safety specification establishes requirements fordevices intended to addres
7、s the risk of injury and deathassociated with accidental falls from windows by children fiveyears old and younger.1.2 This safety specification applies only to window fallprevention devices that are to be used on windows that are notintended for escape (egress) and rescue (ingress).NOTE 1Provisional
8、 Safety Specification PS120 addresses window fallprevention devices (releasable) for windows intended for emergencyescape and rescue and any other window not covered by this speechifi-cation.1.3 This safety specification applies only to devices in-tended to be applied to windows installed at heights
9、 of morethan 75 ft5(23 m) above ground level in multiple familydwelling buildings. This safety specification is not intended toapply to windows below 75 ft (23 m) because all windowsbelow 75 ft (23 m) that are operable could be used as a possiblesecondary means of escape.61.4 This standard does not
10、purport to address all safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and to determine the applicability of regula-tory limitations prior to use.1.5 The values stated in inch-pound units are to
11、 be regardedas the standard. The SI values given in parentheses are forinformation only.2. Referenced Documents2.1 ASTM Standards:7PS 120 Specification for Window Fall Prevention Devices1This safety specification is under the jurisdiction of ASTM Committee F15 onConsumer Products and is the direct r
12、esponsibility of Subcommittee F15.38 onWindow Fall Prevention.Current edition approved Nov. 1, 2005. Published December 2005. Originallyapproved in 2000. Last previous edition approved in 2000 as F 2006 00.2This standard replaces former Provisonal Safety Specification PS 112.3U.S. Consumer Product S
13、afety Commission, special window falls studyconducted in 1991.4U.S. Consumer Product Safety Commission, special window falls studyconducted in 1991 and “Window Safety: Data and Patterns Related to EntrapmentsandAccidental Falls from Windows”, prepared byAnderson Corporation. (ResearchReport F15-1002
14、 available through ASTM.)51994 Uniform Building Code Handbook, Sec. 1807. (a) and 2000 InternationalBuilding CodeSection 403.1 (January 2000; Published Feb. 1, 2000) Specialprovisions for Group B and R1.6This is the intended application of the specification unless otherwise requiredby applicable bui
15、lding code.7For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Dri
16、ve, PO Box C700, West Conshohocken, PA 19428-2959, United States.with Emergency Escape (Egress) Release Mechanisms2.2 ANSI Standard:8ANSI Z97.1-1984 Safety Glazing Materials Used in Build-ings Safety Performance Specifications and Methods ofTest (Tempered Glass Impact Test)3. Terminology3.1 Definiti
17、ons of Terms:3.1.1 window, nan opening constructed in a wall or a roofto admit light or air or both to any enclosure.3.1.2 window falls, na fall from or out of a window.3.1.3 window fall prevention device, n a product installedinto an existing window opening, and in conjunction with theproperly func
18、tioning window unit, for the purpose of prevent-ing children five years old or younger from falling from or outof an open window.3.1.4 emergency escape (egress) and rescue (ingress) win-dow, na window intended for emergency escape (egress) andrescue (ingress) during an emergency situation such as fi
19、re, gasleak, etc., as defined by the prevailing applicable building andfire codes.4. General Requirements4.1 Window fall prevention devices shall be constructed soas to prohibit the free passage of a 4.0 in. (102 mm) diameterrigid sphere9at any point, during or after testing as specified inSection 8
20、, when the window fall prevention device is installedin accordance with the manufacturers instructions.4.2 The distance between window fall prevention devicestructural members or components after all testing is conductedshall not exceed 4.0 in. (102 mm) when a 60 lbf10(267 N)direct force is applied
21、in accordance with the test methodaccording to 8.2.4.3 Window fall prevention devices shall be free of sharpprojections and edges.4.4 Window fall prevention devices shall not interfere withthe design, operation, and function of the window, shall notalter the window in a manner that causes water or a
22、irinfiltration or both, and shall not violate light and ventilationrequirements of the applicable building code.4.5 Each window fall prevention device shall be sold withinstallation instructions and safety information included in thepackaging for each device.4.6 Installation instructions shall inclu
23、de the statement thata copy of the safety information shall be provided to the ownerof the building in which the device is installed and to theoccupant in the dwelling where the device is installed (or is tobe installed).4.7 Installation instructions and safety information shall beconspicuous.4.8 In
24、stallation instructions and safety information shallspecify maximum window opening width and height for whichthe window fall prevention device is intended.5. Installation Instructions5.1 Installation instructions shall specify that window fallprevention devices shall be installed in such manner that
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF200620002005STANDARDSAFETYSPECIFICATIONFORWINDOWFALLPREVENTIONDEVICESFORNONEMERGENCYESCAPEEGRESSANDRESCUEINGRESSWINDOWS

链接地址:http://www.mydoc123.com/p-536269.html