1、Designation: F1802 04 (Reapproved 2010)An American National StandardStandard Test Method forPerformance Testing of Excess Flow Valves1This standard is issued under the fixed designation F1802; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a standardized method todetermine the performance of excess flow valves
3、(EFVs)designed to limit flow or stop flow in thermoplastic natural gasservice lines.21.2 All tests are intended to be performed using air as thetest fluid. Unless otherwise stated, all flow rates are reported instandard cubic feet per hour of 0.6 relative density natural gas.1.3 The test method reco
4、gnizes two types of EFV. One type,an excess flow valve-bypass (EFVB), allows a small amount ofgas to bleed through (bypass) after it has tripped, usually as ameans of automatically resetting the device. The second type,an excess flow valve-non bypass (EFVNB), is intended to tripshut forming an essen
5、tially gas tight seal.1.4 The performance characteristics covered in this testmethod include flow at trip point, pressure drop across theEFV, bypass flow rate of the EFVB or leak rate through theEFVNB after trip, and verification that the EFV can be reset.1.4.1 Gas distribution systems may contain c
6、ondensates andparticulates such as organic matter, sand, dirt, and iron com-pounds. Field experience has shown that the operating charac-teristics of some EFVs may be affected by accumulations ofthese materials. The tests of Section 11 were developed toprovide a simple, inexpensive, reproducible tes
7、t that quantifiesthe effect, if any, of a uniform coating of kerosene and ofkerosene contaminated with a specified amount of ferric oxidepowder on an EFVs operating characteristics.1.5 Excess flow valves covered by this test method willnormally have the following characteristics: a pressure ratingof
8、 up to 125 psig (0.86 MPa); a trip flow of between 200 and2500 ft3/h (5.66 and 70.8 m3/h) at 10 psig (0.07 MPa); aminimum temperature rating of 0F(18C), and a maximumtemperature rating of 100F (38C).1.6 The EFVs covered by this test method shall be con-structed to fit piping systems no smaller than1
9、2 CTS and nolarger than 114 IPS, including both pipe and tubing sizes.1.7 Tests will be performed at 67 6 10F (19.4 6 5.5C).Alternative optional test temperatures are 100 6 10F (37.7 65.5C) and 0 6 10F (18 6 5.5C). All flow rates must becorrected to standard conditions.1.8 This test method was writt
10、en for EFVs installed inthermoplastic piping systems. However, it is expected that thetest method may also be used for similar devices in otherpiping systems.1.9 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI uni
11、ts that are provided for information onlyand are not considered standard.1.10 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine
12、 the applica-bility of regulatory limitations prior to use. For specificprecautions, see Section 8.2. Referenced Documents2.1 ASTM Standards:3D1600 Terminology for Abbreviated Terms Relating toPlasticsF412 Terminology Relating to Plastic Piping Systems2.2 ANSI Standard:B31.8 Gas Transmission and Dis
13、tribution Piping Systems42.3 Federal Specification:DOT Part 192 Title 49 Code of Federal Regulations51This test method is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.40 on TestMethods.Current edition approved Aug. 1, 2010
14、. Published November 2010. Originallyapproved in 1995 as PS 1395. Last previous edition approved in 2004 asF180404. DOI: 10.1520/F1802-04R10.2This contamination test procedure may be utilized to determine the effect, ifany, of contaminants from a specific gas distribution system on the operationalch
15、aracteristics of an EFV under consideration for use in that system. Condensates,oils and particulates removed from that distribution system could be substituted forkerosene and iron oxide. Results obtained from using reagents or contaminants otherthan those specified in this test method must not be
16、used in comparison with resultsobtained using the reagents specified in this test method.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summ
17、ary page onthe ASTM website.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.Available from American National StandardsInstitute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.5Available from Superintendent of Docum
18、ents, U.S. Government PrintingOffice, 732 N. Capitol Street, NW, Washington, DC 20402.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3. Terminology3.1 Definitions:3.1.1 GeneralDefinitions are in accordance with Termi-nology F412, un
19、less otherwise specified. Abbreviations are inaccordance with Terminology D1600.3.1.2 The gas industry terminology used in this test methodis in accordance with ANSI B31.8 or DOT Part 192 Title 49,unless otherwise indicated.3.2 Definitions of Terms Specific to This Standard:3.2.1 bypass flow, nthe f
20、low through an EFVB after it hasbeen activated or tripped.3.2.2 excess flow valve (EFV), na device installed in anatural gas service line having the ability to automatically stopor limit the flow of gas in the event that the flow in the serviceline exceeds a predetermined level.3.2.2.1 excess flow v
21、alve-bypass (EFVB), nan EFV de-signed to limit the flow of gas upon closure to a smallpredetermined level. The EFVBs reset automatically, once theservice line downstream is made gas tight and pressure isequalized across the valve.3.2.2.2 excess flow valve-non bypass (EFVNB), nan EFVwhich is designed
22、 to stop the flow of gas upon closure. TheEFVNBs must be manually reset.3.2.3 leak rate, nthe flow of test fluid passing through anEFVNB after it has been activated or tripped.3.2.4 Piezometer ring, na device installed at a pressuremeasurement point in a flowing gas stream intended toeliminate the e
23、ffect of the flowing gas on the measurementdevice. See Appendix X1.3.2.5 pipe, nrefers to both pipe and tubing.3.2.6 standard conditions, nfor gas flow conversion, 0.6relative density natural gas at 14.7 psia (0.1 MPa) and 60F(16.6 C).3.2.7 trip, nactivation of the mechanism of an EFV tostop or limi
24、t the flow of natural gas in the service line.3.2.8 trip flow, nthe flow passing through an EFV re-quired to cause its activation to stop or limit flow.4. Summary of Test Method4.1 For all tests, air is intended to be the test fluid. All flowsare given in cubic feet per hour of 0.6 relative density
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 1人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF180220042010STANDARDTESTMETHODFORPERFORMANCETESTINGOFEXCESSFLOWVALVES 溢流 性能 测试 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-535702.html