《ASTM F1681-2007a Standard Test Method for Determining Current Carrying Capacity of a Conductor as Part of a Membrane Switch Circuit《测定薄膜开关线路元件导体载流量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1681-2007a Standard Test Method for Determining Current Carrying Capacity of a Conductor as Part of a Membrane Switch Circuit《测定薄膜开关线路元件导体载流量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1681 07aStandard Test Method forDetermining Current Carrying Capacity of a Conductor asPart of a Membrane Switch Circuit1This standard is issued under the fixed designation F 1681; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the currentcarrying capacity of a conductor as
3、part of a membrane switch.1.2 This test method may be used to test a circuit todestruction, that is, to determine its maximum current carryingcapacity, or it may be used to test the ability of a circuit towithstand a desired current level.1.3 This test method applies only to static conditions, anddo
4、es not apply to contact closure cycling of a membrane switchunder current load (test method forthcoming).1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and
5、 health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F 1578 Practice for Contact Closure Cycling of a Mem-brane SwitchF 1680 Test Method for Determining Circuit Resistance of aMembrane Switch3. Terminology3.1 Definitions
6、:3.1.1 conductor resistancethe measured electrical resis-tance through a circuit loop between two test points.3.1.2 DiscussionWhen a switch is included in that loop, itshall be 88closed” in accordance with Test Method F 1680.3.1.3 current carrying capacity (CCC)the maximum levelof electrical current
7、 that a circuit can conduct without sustain-ing damage.3.1.4 membrane switcha momentary switching device inwhich at least one contact is on, or made of, a flexiblesubstrate.3.1.5 power capacityelectrical power is defined ascurrent 3 voltage = V 3 I (watts).3.1.6 test pointstwo preselected conductive
8、 points in acircuit loop, possibly including a switch.4. Significance and Use4.1 Current carrying capacity is used by designers andmanufacturers of electronic interface circuitry to ensure thatthe membrane switch can reliably handle the loads occurring innormal use and under extreme circumstances. A
9、 thoroughunderstanding of CCC allows manufacturers to take it intoaccount when developing design rules for membrane switches.4.2 Failures due to exceeding the CCC of a circuit may takethe form of a significant change in conductor resistance,insulation breakdown (shorts), or conductor breakdown(opens
10、).4.3 Since a number of design parameters, such as tracewidth, ink film thickness, etc. affect the final test results, anyconclusions should only be applied to specific designs, ratherthan to a general combination of materials.4.4 Current carrying capacity tests may be destructive andunits that have
11、 been tested should be considered unreliable forfuture use.4.5 Current carrying capacity may be significantly differentfor static loads and dynamic (that is, cycling) loads. Failuremodes are also generally different.4.6 The use of a thermocouple to monitor the temperature ofthe UUT may be helpful to
12、 monitor the progress of the test.1This test method is under the jurisdiction of ASTM Committee F01 onElectronics and is the direct responsibility of Subcommittee F01.18 on MembraneSwitches.Current edition approved Dec. 1, 2007. Published December 2007. Originallyapproved in 1996. Last previous edit
13、ion approved in 2007 as F 168107.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM Internationa
14、l, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.7 Initial expected starting current should be calculated inadvance to prevent damage to test equipment.5. Interferences5.1 The following parameters may affect the results of thistest:5.1.1 Temperature,5.1.2 Rela
15、tive humidity, and5.1.3 Barometric pressure.6. Hazard6.1 The user must be aware of the operating range of theirequipment to prevent damage to the device from overloadduring testing. For example, the current should be adjustedstarting from a minimum setting, and a decade box should starton the highes
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF16812007ASTANDARDTESTMETHODFORDETERMININGCURRENTCARRYINGCAPACITYOFACONDUCTORASPARTOFAMEMBRANESWITCHCIRCUIT

链接地址:http://www.mydoc123.com/p-535394.html