1、Designation: F1640 09F1640 16Standard Guide forSelection and Use of PackagingContact Materials for Foodsto Be Irradiated1This standard is issued under the fixed designation F1640; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis guide provides information on the selection and use of packagingcontact materials forpackaging intended
3、to hold food during irradiationtreatment with ionizing energy (gamma-rays,X-rays, accelerated electrons). In general, irradiation is used to reduce the incidence of spoilage andpathogenic microorganisms and parasites in foods, control sprouting of tubers and bulbs, and disinfestcommodities (see Guid
4、es F1355, F1356, F1736, and F1885). Packaging Food contact materials serveto protect the product from recontamination after irradiation and may be used to complement otherpreservation techniques to extend shelf life of the irradiated food. Molecules from food contactmaterials can migrate to the food
5、 when these materials are in contact with the food. Because of this,in many countries regulations are made to ensure food safety. The amended FDirradiation, but it does not address all regulatory issues associated with the selection and use ofpackaging materials for foods to be irradiated. It is the
6、 responsibility of the user of this guide to determine the pertinent regulatoryissues in each country where foods are to be irradiated and where irradiated foods are distributed.1.3 This guide does not address all of the food safety issues associated with the synergistic effects of irradiation and p
7、ackagingas food preservation techniques on the extension of shelf life or food quality. It is the responsibility of the user of this guide todetermine the critical food safety issues and to conduct appropriate product assessment tests to determine the compatibilitybetween the packaging application a
8、nd irradiation relative to changes in sensory attributes and shelf life.1.4 This guide does not address the use of irradiation as a processing aid for the production or sterilization of food packagingmaterials.1.5 The values stated in SI units are to be regarded as standard. No other units of measur
9、ement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimita
10、tions prior to use.1 This guide is under the jurisdiction of ASTM Committee E61 on Radiation Processing and is the direct responsibility of Subcommittee E61.05 on Food Irradiation.Current edition approved Feb. 1, 2009June 1, 2016. Published March 2009July 2016. Originally approved in 1995. Last prev
11、ious edition approved in 20032009 asF1640 03.F1640 09. DOI: 10.1520/F1640-09.10.1520/F1640-16.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically poss
12、ible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, We
13、st Conshohocken, PA 19428-2959. United States12. Referenced Documents2.1 ASTM Standards:2E170 Terminology Relating to Radiation Measurements and DosimetryE460 Practice for Determining Effect of Packaging on Food and Beverage Products During StorageE462 Test Method for Odor and Taste Transfer From Pa
14、ckaging Film (Withdrawn 1998)3F1355 Guide for Irradiation of Fresh Agricultural Produce as a Phytosanitary TreatmentF1356 Guide for Irradiation of Fresh, Frozen or Processed Meat and Poultry to Control Pathogens and Other MicroorganismsF1736 Guide for Irradiation of Finfish and Aquatic Invertebrates
15、 Used as Food to Control Pathogens and SpoilageMicroorganismsF1885 Guide for Irradiation of Dried Spices, Herbs, and Vegetable Seasonings to Control Pathogens and Other Microorganisms3. Terminology3.1 Definitions:3.1.1 absorbed dosedose (D)quantity of ionizingICRU-85a, 5.2.5 quotient of d radiation
16、by dm, where denergyimparted per unit mass of specified material. is the mean incremental energy imparted by ionizing radiation to matter of mass dm,The thusSID 5d/dmunit for absorbed dose is the gray (Gy), where one gray is equivalent to the absorption of 1 joule per kilogram of the specifiedmateri
17、al (1Gy = 1 J/kg).3.1.1.1 DiscussionA standard definitionThe SI unit of absorbed dose appears in Terminologyis the gray E170.(Gy), where 1 gray is equivalent to theabsorption of 1 joule per kilogram of the specified material (1 Gy=1 J/kg).3.1.2 absorbed-dose rateabsorbed dose rate (D)the absorbed do
18、se in a material per incremental time interval; ie., thequotient of ICRU-85a, 5.2.6quotient of ddDD by ddtt (D =where dD disD/dt). The SI unit for absorbed-dose rate is Gys theincrement of absorbed dose in the time-1. interval dt, thusD 5dD/dt3.1.2.1 DiscussionA standard definition of absorbed dose
19、appears in Terminology E170.(1) The SI unit is Gy-s1. However, the absorbed-dose rate is often specified in terms of its average value over longer timeintervals, for example, in units of Gymin1 or Gyh1.(2) In gamma industrial irradiators, dose rate may be significantly different at different locatio
20、ns.(3) In electron-beam irradiators with pulsed or scanned beam, there are two types of dose rate: average value over severalpulses (scans) and instantaneous value within a pulse (scan). These two values can be significantly different.3.1.3 anaerobic environmentan environment having a level of oxyge
21、n that will not support the growth of oxygen-requiringmicroorganisms.3.1.4 food contact material (also referred to as contact materialany material (not only packaging) that is expected to comeinto contact with food.3.1.4.1 DiscussionFood contact materials are either intended to be brought into conta
22、ct with food, are already in contact with food, or can reasonablybe brought into contact with food which could lead to the transfer of their constituents to the food under normal or foreseeableuse. Food contact materials can be constructed from a variety of materials like plastics, rubber, paper, co
23、atings, metal, etc. In manycases a combination is used; for example, a carton box for juices can include (from the inside to the outside): plastic layer,aluminum, paper, printing and top coating.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at s
24、erviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.F1640 1623.1.5 good manufacturing practice (GMP)procedures established and exerc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF16402016STANDARDGUIDEFORSELECTIONANDUSEOFCONTACTMATERIALSFORFOODSTOBEIRRADIATED 辐射 食品 接触 材料 选择 使用

链接地址:http://www.mydoc123.com/p-535303.html