ASTM F1115-2016 Standard Test Method for Determining the Carbon Dioxide Loss of Beverage Containers《测定饮料容器二氧化碳损失的标准试验方法》.pdf
《ASTM F1115-2016 Standard Test Method for Determining the Carbon Dioxide Loss of Beverage Containers《测定饮料容器二氧化碳损失的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1115-2016 Standard Test Method for Determining the Carbon Dioxide Loss of Beverage Containers《测定饮料容器二氧化碳损失的标准试验方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1115 16Standard Test Method forDetermining the Carbon Dioxide Loss of BeverageContainers1This standard is issued under the fixed designation F1115; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 The objective of this test method is to determine thecarbon dioxide (CO2) loss from plastic beverage containersafter a specifie
3、d period of storage time.1.2 Factors contributing to this pressure loss are volumeexpansion and the gas transport characteristics of the package,including permeation and leakage.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandar
4、d.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced
5、 Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent Water3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 automated CO2analyzeran electronic unit that willpierce the roll-on closure and automatically read pressure andtemperature and
6、calculate volume of gas (Procedure B). Thereare multiple manufacturers of these instruments.3.1.2 carbonation volumethe volume of CO2(at 0C, 1atm pressure) that is dissolved in the carbonated water, dividedby the volume of the liquid (based on water volume at 3.98Cequals 1.000 g/cm3). The conversion
7、 of pressure to carbonationvolumes should be made using a carbonation volumes table. Atable for carbonated water would not necessarily apply toliquids containing additional substances, such as carbonatedbeverages containing sugar.3.1.3 finishthe threaded part of the bottle which receivesthe cap.3.1.
8、4 initial pressurethe equilibrium pressure in the testbottles as measured at 24 h after filling with carbonated water.(The filled bottles are allowed to stand for 24 h to obtaintemperature equilibrium with the test environment and to allowtime for pressure adjustment and equilibration of the CO2inth
9、e headspace and liquid).3.1.5 manual pressure testera unit that manually piercesthe closure and measures container pressure; an attachedthermometer is then used to measure temperature (ProcedureB).3.1.6 pressure monitoring devicea pressure gage or trans-ducer assembly with support electronics for in
10、dicating internalpressure level of the bottle. This device is used with brassclosure fitting-equipped bottles.3.1.7 samplea set of bottles produced on the same equip-ment in a single run and using the same material and processconditions. Bottles should represent normal thickness distribu-tion.3.1.8
11、shelf lifethe number of weeks a sample set of bottlesretain a specified carbonation level, or a percent of the initiallevel.3.1.9 support ringa protrusion below the bottle finishwhich is used to support or stabilize the bottle during fillingand capping.3.1.10 temperature monitoring devicea thermocou
12、plewith support electronics (same equipment as described in7.2.2). A precision glass thermometer may be used, provided abottle filled with noncarbonated water is used as a control ineach sample set (Procedure A).3.2 For other terms used in this test method, refer toTerminology D1129.4. Summary of Te
13、st Method4.1 Test bottles are filled with carbonated water or beverageand, after closure application, are exposed to test environments1This test method is under the jurisdiction of ASTM Committee F02 on PrimaryBarrier Packaging and is the direct responsibility of Subcommittee F02.10 onPermeation.Cur
14、rent edition approved Oct. 1, 2016. Published XXXX 2016. Originallyapproved in 1987. Last previous edition approved in 2008 as F1115 95 (2008)1.DOI: 10.1520/F1115-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual B
15、ook of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1for specified time periods. By periodically measuring the initialand final carbon
16、ation levels in the container, the carbonationloss and carbonation transfer rate can be calculated.5. Significance and Use5.1 Two procedures, A and B, are outlined in this testmethod. Procedure A is used most often for development ofvarious beverage container designs to determine the functionalchara
17、cteristics of the package in regard to shelf life. ProcedureB is recommended for use in beverage filling operations as aquality control tool in maintaining the desired CO2fill pres-sure. A loss of CO2will affect product taste.5.1.1 Procedure A involves the use of sensitive pressure andtemperature mo
18、nitoring equipment where a high degree ofaccuracy is essential, for example, a micro-pressure transducerand thermocouple for measuring pressure and temperature ofthe package in a closed system. Alternatively, this proceduremay also use bottles closed with roll-on aluminum capscontaining rubber septu
19、ms. The septum is pierced with ahypodermic needle attached to a pressure transducer to obtainpressure readings. This procedure should be confined tolaboratories that are practiced in this type of analytical testing.5.1.2 Procedure B is more widely used when measuring thecarbonation level of the pack
20、age due to the simplicity of thetechnique. A simple Manual pressure assembly or an Auto-mated CO2Analyzer is utilized.6. Interferences6.1 The following conditions can interfere with the testresults:6.1.1 CO2leakage at closure due to defective bottle finish orimproper sealing of closure apparatus,6.1
21、.2 CO2leakage due to improper equipment set-up,6.1.3 Change in ambient temperature, upsetting the equilib-rium of the headspace and dissolved CO2gas,6.1.4 Measurement of pressure before the bottle and liquidhave reached ambient temperature,6.1.5 Inaccurate thermocouple device used for measuringthe l
22、iquid temperature,6.1.6 Excessive air in the bottle headspace or dissolved inthe liquid,6.1.7 Inaccurate or erratic pressure monitoring device,6.1.8 Ambient humidity in the test area,6.1.9 Age of bottles, and6.1.10 Excessive bottle-to-bottle variation in the materialdistribution, which may result in
23、 a wide variation from bottle tobottle within the sample population.7. Apparatus7.1 Procedures A and B:7.1.1 Bottle Stand, optional.7.1.2 Height Measuring Device, capable of measuring towithin 0.001 in. (optional).7.1.3 Top Loading Balance, capable of weighing to 2500 gwith an accuracy of 60.01 g (o
24、ptional).7.1.4 Outside Diameter Measuring Device, tape or similardevice (optional).7.1.5 Carbonated Water or Beverage Dispensing Equip-ment.7.1.6 Micrometer or Ultrasonic Thickness Gage, capable ofmeasuring to within 0.001 in. or less (optional).7.2 Procedure A:7.2.1 Machined Metal Cap (see Fig. 1).
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF11152016STANDARDTESTMETHODFORDETERMININGTHECARBONDIOXIDELOSSOFBEVERAGECONTAINERS 测定 饮料 容器 二氧化碳 损失

链接地址:http://www.mydoc123.com/p-534214.html