《ASTM E997-2012 red 9375 Standard Test Method for Structural Performance of Glass in Exterior Windows Curtain Walls and Doors Under the Influence of Uniform Static Loads by Destruct.pdf》由会员分享,可在线阅读,更多相关《ASTM E997-2012 red 9375 Standard Test Method for Structural Performance of Glass in Exterior Windows Curtain Walls and Doors Under the Influence of Uniform Static Loads by Destruct.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:E99711 Designation: E997 12Standard Test Method forStructural Performance of Glass in Exterior Windows,Curtain Walls, and Doors Under the Influence of UniformStatic Loads by Destructive Methods1This standard is issued under the fixed designation E997; the number immediately following the
2、 designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is a pro
3、cedure to determine if the probability of breakage of glass specimens tested is significantly greaterthan, significantly less than, or not significantly different than the specified probability of breakage when exposed to a specifieddesign load. It is not intended to be a design standard for determi
4、ning the load resistance of glass. Practice E1300 shall be usedfor this purpose.1.2 This test method describes apparatus and procedures to select and apply a proof load to glass specimens, to determine thenumber of glass specimens to be tested, and to evaluate statistically the probability of breaka
5、ge.This test method may be conductedusing the standard test frame specified herein or a test frame of the users design.1.3 Proper use of this test method requires a knowledge of the principles of pressure measurement and an understanding ofrecommended glazing practices.1.4 The values stated in inch-
6、pound units are to be regarded as standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulator
7、ylimitations prior to use. Specific precautionary statements are given in Section 7.1This test method is under the jurisdiction of ASTM Committee E06 on Performance of Buildings and is the direct responsibility of E06.51 on Performance of Windows,Doors, Skylights and Curtain Walls.Current edition ap
8、proved Nov.April 15, 2011.2012. Published December 2011.May 2012. Originally approved in 1984. Last previous edition approved in 2009 asE99701(2009).E997 11. DOI: 10.1520/E0997-112.1This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of wh
9、at changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered th
10、e official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2. Referenced Documents2.1 ASTM Standards:2E631 Terminology of Building ConstructionsE1300 Practice for Determining Load Resistance of Glass in Buildings3. Terminolog
11、y3.1 Definitions:3.1.13.1.1 For definitions of general terms related to building construction used in this test method refer to Terminology E631.3.2 Definitions of Terms Specific to This Standard:3.2.1 coeffcient of variation, nratio of the standard deviation of the breakage load to the mean breakag
12、e load.3.1.23.2.2 equivalent design load, nthe specified uniform design load converted to specified duration (see 4.2).3.1.33.2.3 glass specimen, nthe glass to be tested, for example, a single pane, an insulating glass unit, laminated glass, etc. (doesnot include test frame).3.1.43.2.4 glass specime
13、n breakage, nthe fracture or cracking of any glass component of a glass specimen.3.1.53.2.5 negative load, nan outward-acting load that results in the indoor side of a glass specimen being the high-pressure side.3.1.63.2.6 positive load, nan inward-acting load that results in the outdoor side of a g
14、lass specimen being the high-pressure side.3.1.73.2.7 probability of breakage, nthe probability that a glass specimen will break when tested at a given load. General industrypractice is to express the probability of breakage as lites per 1000 lites.3.1.83.2.8 proof load, na magnitude of uniform load
15、 at which glass specimens shall be tested.3.1.93.2.9 proof load factor, a, nthe constant which, when multiplied by the design load, determines the proof load.3.1.103.2.10 specifying authority, nprofessional(s) responsible for determining and furnishing information required to perform thetest.4. Summ
16、ary of Test Method4.1 This test method consists of individually glazing glass specimens in a test frame that is mounted into or against one faceof a test chamber and supplying air to, or exhausting air from, the test chamber so that each glass specimen is exposed to a specifiedduration proof load. L
17、oad-time records shall be kept for each glass specimen. Each glass specimen break shall be recorded.4.2 After testing the required number of glass specimens, it is determined if the probability of breakage is significantly less than,significantly greater than, or not significantly different than the
18、 specified probability of breakage.5. Significance and Use5.1 Glass specimens to be tested shall be mounted in a standard test frame with four sides supported, or in a test frame designedto represent specific glazing conditions.5.1.1 Astandard test frame shall be used when it is desired to evaluate
19、the probability of breakage of glass specimens with edgesupport conditions held constant.5.1.2 A test frame designed to represent a specific glazing condition shall be used when it is desired to evaluate the probabilityof breakage of glass specimens in the specified glazing system.5.2 Loads on glass
20、 in windows, curtain walls, and doors may vary greatly in magnitude, direction, and duration.Any load (wind,snow, etc.) that can be transformed into a 60-sspecific duration equivalent uniform design load can be considered. Loadtransformation techniques are addressed in the literature (1, 2, 3).35.3
21、The strength of glass varies with many different factors including surface condition, load duration, geometry, relativehumidity, and temperature (4). A thorough understanding of those strength variations is required to interpret results of this testmethod.2For referencedASTM standards, visit theASTM
22、 website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3The boldface numbers in parentheses refer to a list of references at the end of this standard.E997 1226.
23、Apparatus6.1 The description of apparatus is general in nature. Any equipment capable of performing the test procedure within theallowable tolerances is permitted.6.2 Major Components:6.2.1 Test Frame, in which glass specimens are mounted for testing. The test frame shall provide either standardized
24、 supportconditions or specified support conditions. Specifications of standardized support conditions are presented in Annex A1.6.2.2 Test Chamber, sealed, with an opening in which or against which the test frame is installed. At least one static pressuretap shall be provided to measure the test cha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME9972012RED9375STANDARDTESTMETHODFORSTRUCTURALPERFORMANCEOFGLASSINEXTERIORWINDOWSCURTAINWALLSANDDOORSUNDERTHEINFLUENCEOFUNIFORMSTATICLOADSBYDESTRUCTPDF

链接地址:http://www.mydoc123.com/p-533930.html