1、Designation: E977 05 (Reapproved 2010)Standard Practice forThermoelectric Sorting of Electrically Conductive Materials1This standard is issued under the fixed designation E977; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the procedure for sorting materialsusing the thermoelectric method, which is based on theSe
3、ebeck effect. The procedure relates to the use of direct- andcomparator-type thermoelectric instruments for distinguishingvariations in materials which affect the thermoelectric proper-ties of those materials.1.2 While the practice is most commonly applied to thesorting of metals, it may be applied
4、to other electricallyconductive materials.1.3 Thermoelectric sorting may also be applied to thesorting of materials on the basis of plating thickness, casedepth, and hardness.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibi
5、lity of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Descriptions of Terms:2.1.1 acceptance limitsthe thermoelectric response thatestablishes the group into which the material
6、 being examinedbelongs.2.1.2 comparative instrumentationa system that useselectrode assemblies (probes), associated electronics, andknown standards to measure a thermoelectric response from anelectrically-conductive material. This response is comparedwith that of the reference standard.2.1.3 direct
7、instrumentationa system that specificallymeasures and displays the voltage (or an arbitrary unit)generated between the electrodes when they are at differenttemperatures and in contact with the material.2.1.4 electrodethe conductors used in thermoelectric sort-ing instruments used to generate the See
8、beck effect with thematerial under test.2.1.5 Seebeck effectthe thermoelectric electromotive force(emf) produced in a circuit connecting two dissimilar conduc-tors at two points of different temperatures. The magnitude ofthis emf is a function of the chemistry of the materials, surfacemetallurgical
9、structure, and the temperature at the junctions.See Fig. 1.3. Summary of Practice3.1 The two techniques that are primarily used in thermo-electric sorting are direct and comparative instrumentation. Inthe direct instruments, equipment is standardized by placingmaterials with known chemistry and meta
10、llurgical structure inthe test system. The value of the thermoelectric voltage (orarbitrary unit) is read on the scale of an indicator. In thecomparative instruments, the thermoelectric response of thetest piece is compared with that of a known standard(s) and theresponse indicates whether the piece
11、 is within the acceptancelimits.3.1.1 Both kinds of instrumentation require comparing thepieces to be examined with the known standard(s). Two ormore samples representing the acceptance limits may berequired.3.1.2 Direct Thermoelectric Instrumentationa knownstandard(s) is inserted in the system and
12、the controls of theinstrument are adjusted to obtain a voltage (or arbitrary unit)reading(s). The process is then continued by inserting thepieces to be sorted into the system, and observing the instru-ment reading(s).3.1.3 Comparative InstrumentationKnown standards rep-resenting the acceptance limi
13、ts are inserted into the system.The instrument controls are adjusted for appropriate response.The process is then continued by inserting the pieces to besorted in the system, and observing the instrument response.3.2 In both instruments, the range of the instrument re-sponse must be adjusted during
14、standardization so that anyanticipated deviation from the known standard(s) will berecognized as within the required acceptance limits.3.3 The examination process may consist of manual inser-tion of one piece after another into the system, or an automatedfeeding and classifying mechanism may be empl
15、oyed.4. Application4.1 Thermoelectric techniques provide a method for sortinglarge quantities of conductive materials. The ability to accom-plish satisfactorily these types of separations is dependent upon1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and i
16、s the direct responsibility of Subcommittee E07.10 onSpecialized NDT Methods.Current edition approved June 1, 2010. Published November 2010. Originallyapproved in 1984. Last previous edition approved in 2005 as E977 - 05. DOI:10.1520/E0977-05R10.1Copyright ASTM International, 100 Barr Harbor Drive,
17、PO Box C700, West Conshohocken, PA 19428-2959, United States.the relation of the thermoelectric voltages with regard tocomposition, condition, structure, and processing.4.2 Comparative instrumentation is used when high-sensitivity testing is required. The advantage of this method isthat it reduces i
18、nternal or external disturbances such astemperature variations of the material or probes, or both.4.3 The success of an attempted sort will be affected byinstrument factors such as electrode composition, electrodetemperature differential, and electrode contact.4.4 The degree of reliability of instru
19、ment readings will beaffected greatly by the coupling between the electrodes and thepart and the accuracy with which the temperature is heldconstant during the measuring period. The surface of thematerials and of both electrodes must be kept free of anyinsulating materials such as surface oxide, dir
20、t, paint, or otherforeign material.5. Interference5.1 The specific influence of the following variables must beconsidered for proper interpretation of the results obtained:5.1.1 A correlation shall be established so that if thethermoelectric properties of the various groups overlap, auxil-iary metho
21、ds are used for supplementary examination.5.1.2 In sorting materials, a temperature differential must beused that will result in a well-defined separation of thethermoelectric properties.5.1.3 Contaminates that will electrically insulate materialbeing examined, such as rust, grease, oil, mill scale;
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME977200520108125STANDARDPRACTICEFORTHERMOELECTRICSORTINGOFELECTRICALLYCONDUCTIVEMATERIALS 传导 材料 热电

链接地址:http://www.mydoc123.com/p-533894.html