ASTM E738-2011 1875 Standard Test Method for Determination of Aluminum in Iron Ores and Related Materials by EDTA Complexometric Titrimetry《乙二胺四醋酸络合滴定法测定铁矿石及相关材料中铝含量的标准试验方法》.pdf
《ASTM E738-2011 1875 Standard Test Method for Determination of Aluminum in Iron Ores and Related Materials by EDTA Complexometric Titrimetry《乙二胺四醋酸络合滴定法测定铁矿石及相关材料中铝含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E738-2011 1875 Standard Test Method for Determination of Aluminum in Iron Ores and Related Materials by EDTA Complexometric Titrimetry《乙二胺四醋酸络合滴定法测定铁矿石及相关材料中铝含量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E738 11Standard Test Method forDetermination of Aluminum in Iron Ores and RelatedMaterials by EDTA Complexometric Titrimetry1This standard is issued under the fixed designation E738; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method2covers the determination of aluminumin iron ores, concentrates, and agglomer
3、ates in the composi-tional range from 0.25 % to 5 % aluminum.NOTE 1As used in this test method (except as related to the termrelative standard deviation), “percent” or “%” refers to mass fraction(wt/wt) of the form g/100g.1.2 The values stated in SI units are to be regarded asstandard. No other unit
4、s of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regul
5、atory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D1193 Specification for Reagent WaterE50 Practices for Apparatus, Reagents, and Safety Consid-erations for Chemical Analysis of Metals, Ores, andRelated MaterialsE135 Terminology Relating to Analytical Chemistry forMetals, Ore
6、s, and Related MaterialsE877 Practice for Sampling and Sample Preparation of IronOres and Related Materials for Determination of ChemicalCompositionE882 Guide for Accountability and Quality Control in theChemical Analysis Laboratory3. Terminology3.1 DefinitionsFor definitions of terms used in this t
7、estmethod, refer to Terminology E135.4. Summary of Test Method4.1 The sample is fused in a zirconium crucible with amixed flux of sodium carbonate and sodium peroxide. Thefused mass is dissolved in dilute HCL. The R2O3(Note 2)hydroxides are precipitated with ammonia and redissolved inHCL. Iron, tita
8、nium, and so forth, are removed with cupferronand chloroform. The aqueous phase is treated with H2NO3andHClO4and evaporated to dryness. After dissolving in diluteHCL, the solution is filtered, and the filtrate is treated with anexcess of ethylenediaminetetraacetic acid (EDTA). The excessEDTA is titr
9、ated with a standard zinc solution using xylenolorange indicator. Ammonium fluoride is added to release theEDTA bound to aluminum. This EDTA is then titrated withstandard zinc solution, and the percent aluminum is calculated.NOTE 2R2O3hydroxides are rare earth sesquioxides such as La2O3,Y2O3,Ce2O3,G
10、d2O3, and Eu2O3.5. Significance and Use5.1 This test method for the analysis of iron ore concentratesand agglomerates is primarily intended as a referee method totest for compliance with compositional specifications. It isassumed that all who use this test method will be trainedanalysts capable of p
11、erforming common laboratory proceduresskillfully and safely. It is expected that work will be performedin a properly equipped laboratory and that proper wastedisposal procedures will be followed. Appropriate qualitycontrol practices shall be followed, such as those described inGuide E882.6. Interfer
12、ences6.1 None of the elements normally found in iron oresinterfere with this test method.7. Apparatus7.1 Zirconium Crucible, 50-mL.1This test method is under the jurisdiction of ASTM Committee E01 onAnalytical Chemistry for Metals, Ores, and Related Materials and is the directresponsibility of Subco
13、mmittee E01.02 on Ores, Concentrates, and Related Metal-lurgical Materials.Current edition approved Sept. 1, 2011. Published September 2011. Originallyapproved in 1980. Last previous edition approved in 2005 as E738 00(2005). DOI:10.1520/E0738-11.2Bhargava, O. P., “Complexometric Determination of Al
14、uminum in Iron Ore,Sinter, Concentrates, and Agglomerates,” Talanta, Vol 26, 1979, pp. 146 to 148.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Docu
15、ment Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.8. Reagents and Materials8.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall
16、 reagents conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society wheresuch specifications are available.4Other grades may be used,provided it is first ascertained that the reagent is of sufficienthigh purity to permit its use without lessening the accur
17、acy ofthe determination.8.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water conformingto Type I or II of Specification D1193. Type III or IV may beused if they effect no measurable change in the blank orsample.8.3 Ammonium Chloride Solution (10
18、 g/L)Dissolve 10 gof ammonium chloride in water and dilute to 1 L. Add 2 drops(0.1 mL) of ammonium hydroxide per 100 mL of solution.8.4 Ammonium Fluoride SolutionDissolve 10 g of ammo-nium fluoride (NH4F) in 100 mL of water in a polyethylenebeaker. Prepare fresh each day.8.5 Cupferron Solution (60 g
19、/L)Dissolve6gofcupferronin 80 mL of cold water, dilute to 100 mL, and filter. Preparefresh as needed.8.6 Ethylenediaminetetraacetic Acid (EDTA) Solution(0.01 mol/L).8.7 Sodium Acetate Buffer SolutionDissolve 136 g ofsodium acetate trihydrate (CH3COONa3H2O) in about 600mL of water. Add 7 mL of glacia
20、l acetic acid and dilute to 1 L.Store in a polyethylene bottle.8.8 Sodium Carbonate.8.9 Sodium Hydroxide Solution A.8.9.1 Dissolve 100 g of sodium hydroxide (NaOH) in about100 mL of water. When dissolution is complete, cool, anddilute to 1 L. Store in a plastic bottle.8.10 Sodium Hydroxide Solution
21、BDilute 100 mL ofsodium hydroxide solution A to 1 L with water.8.11 Sodium Peroxide.8.12 Xylenol Orange IndicatorThoroughly grind 0.1 gxylenol orange with a little water to make a fine paste. Diluteto 100 mL with water, filter, and store in an amber-coloredglass stoppered bottle. The solution is sta
22、ble for 1 week.8.13 Zinc, Standard Solution (0.01 M)Weigh 0.6538 g ofhigh purity (99.99 % zinc) zinc metal into a 125-mL Erlen-meyer flask. Add 5 mL of water followed by 2 to 3 mL ofHNO3. Cover the flask and simmer. If the reaction subsidesleaving undissolved metal, add 2-mL increments of waterfollo
23、wed by simmering until complete solution is obtained.Add 50 mL of water and gently boil for 2 min. Cool. Bydropwise addition of sodium hydroxide solution B, adjust thepH to 4. Dilute to 1 L with water in a volumetric flask.9. Hazards9.1 For precautions to be observed in this method, refer toPractice
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME73820111875STANDARDTESTMETHODFORDETERMINATIONOFALUMINUMINIRONORESANDRELATEDMATERIALSBYEDTACOMPLEXOMETRICTITRIMETRY

链接地址:http://www.mydoc123.com/p-533425.html