ASTM E546-2008 402 Standard Test Method for Frost Dew Point of Sealed Insulating Glass Units《密封绝缘玻璃装置露 霜点的标准试验方法》.pdf
《ASTM E546-2008 402 Standard Test Method for Frost Dew Point of Sealed Insulating Glass Units《密封绝缘玻璃装置露 霜点的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E546-2008 402 Standard Test Method for Frost Dew Point of Sealed Insulating Glass Units《密封绝缘玻璃装置露 霜点的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 546 08An American National StandardStandard Test Method forFrost/Dew Point of Sealed Insulating Glass Units1This standard is issued under the fixed designation E 546; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method describe
3、s a laboratory procedure fordetermining the frost/dew point within the air space(s) ofsealed insulating glass units, and establishes the criteria fordetermining whether that point is below or above a given orspecified temperature.1.2 This test method also describes the apparatus to be usedfor these
4、determinations.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard t
5、o establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see 9.1.3.2. Referenced Documents2.1 ASTM Standards:2C 1036 Specification for Flat GlassE77 Test Method for Inspection and Verification of Ther
6、-mometersE 576 Test Method for Frost/Dew Point of Sealed InsulatingGlass Units in the Vertical PositionE 631 Terminology of Building Constructions3. Terminology3.1 DefinitionsFor definitions of general terms used inthis test method, refer to Terminology E 631.3.2 Definitions of Terms Specific to Thi
7、s Standard:3.2.1 frost statethe case where the frost/dew point of asealed insulating glass unit is above the test temperaturespecified by the purchaser or user.3.2.2 frost/dew point, nthe temperature at which water,organic vapor, or other chemicals begin to appear on theinterior glass surface of a s
8、ealed insulating glass unit in contactwith the measuring surface of the frost/dew-point apparatus.3.2.3 no-frost statethe case where the frost/dew point of asealed insulating glass unit is below the temperature specifiedby the purchaser or user.4. Summary of Test Method4.1 This test method is conduc
9、ted by the use of a specialapparatus, consisting basically of two chilled cylindrical metalblocks positioned one over the other and separated by a gap ofcontrollable distance. The upper block has an exposed flatcircular surface, 25 mm (1 in.) in diameter, and can be chilledto far below the ice point
10、 by regulating the air-gap distancebetween it and the lower metal block which is maintained atapproximately 78C (109F) by dry ice. The test specimenis placed in contact with this chilled flat circular surface of theupper block for specified short periods of time, with the metalsurface at successivel
11、y lower temperatures, to determine atwhat temperature frost appears on the corresponding lower airspace glass surface.5. Significance and Use5.1 This test method and the apparatus described are in-tended primarily for sealed insulating glass units positionedhorizontally. If the procedure is applied
12、to such units in otherthan a horizontal position, the results may not be comparable tothose obtained by this procedure.NOTE 1A similar method is Test Method E 576.6. Apparatus6.1 Test Apparatus3(see Fig. 1), consisting of upper andlower cylindrical metal blocks with a thermocouple, bimetallicthermom
13、eter, or other suitable temperature sensors beinginserted in the upper block; a control ring; and an insulated1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.22on Durability Performance of Building Cons
14、tructions.Current edition approved April 1, 2008. Published May 2008. Originallyapproved in 1975. Last previous edition approved in 1999 as E 546 88 (1999)e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of A
15、STMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The sole source of supply of the apparatus known to the committee at this timeis Dennis Industries, 20032 Waynegarden Court, Germantown, MD 20874, http:/. If you are aware of alternative suppliers, plea
16、se provide thisinformation to ASTM International Headquarters. Your comments will receivecareful consideration at a meeting of the responsible technical committee,1whichyou may attend.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.c
17、ontainment cylinder fitted with a retainer spring assembly.The two metal blocks are separated by a small air gap, thedistance of which can be regulated by the control ring. Theexposed flat circular surface of the upper block is 25 mm (1 in.)in diameter; has a ground or lapped finish; and, when place
18、d incontact with the glass test specimen, forms the frost/dew pointmeasuring surface. The lower block is chilled by a dry ice packkept in contact with it by the retainer spring assembly,maintaining it at a temperature near to that of sublimating dryice (78C (109F). Because the solid metal blocks are
19、highly conductive, the temperature of each is virtually uniform.Use of the control ring adjusts the air gap distance between thetwo blocks to give the desired thermal resistance across the airgap. The circular measuring surface of the upper block is thusreadily adjusted to the desired temperature wh
20、ile in contactwith the test specimen. The circular measuring surface diam-eter specified is suitable for frost/dew point measurement ofglass up to 6.0 mm (14 in.) thick.6.1.1 Upper and Lower Metal Blocks, aluminum alloy thatmay be anodized, conforming to the dimensions shown in Fig.1. Other parts of
21、 the apparatus may be fabricated from anyappropriate materials.6.1.2 Calibrated Temperature-Measuring Device; such as athermocouple, thermistor, or bimetallic thermometer; having aParts ListPart No. Nomenclature Part No. Nomenclature1 upper metal block 12 supporting ring, bottom of inner tube2 lower
22、 metal block 13 control ring3 top cover 14 cover lid, inner tube4 supporting plate, upper metal block 15 elbow5 spacer 16 tube, nylon6 spring, upper metal block 17 main spring7 supporting plate, top of inner tube 18 spacer8 outer tube 19 bearing9 inner tube 20 bimetallic dial thermometer10 disk, dry
23、 ice pushing 21 dial indicator11 clamp, dial gage 22 heat source blockFIG. 1 Schematic Diagram of Frost/Dew-Point ApparatusE546082suitable range graduated in 1C (2F) or smaller units; and anaccuracy of 60.5C (61F) over the full scale. A suggestedcalibration of the bimetallic thermometer is described
24、 inAppendix X1.7. Test Specimen7.1 The specimen to be tested shall be representative of theunits to be evaluated and capable of being positioned horizon-tally.8. Conditioning8.1 Prior to testing, condition the test specimen at a tem-perature of 24 6 3C (75 6 5F) for not less than 24 h.9. Procedure9.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME5462008402STANDARDTESTMETHODFORFROSTDEWPOINTOFSEALEDINSULATINGGLASSUNITS 密封 绝缘 玻璃 装置 露霜点 标准 试验 方法

链接地址:http://www.mydoc123.com/p-533012.html